摘要
Purpose: To assess dynamic variations in vault induced by changes in brightness in eyes implanted with phakic collamer intraocular lens (pIOL) with central port for correction of myopia, defining new parameters of vaulting measurement. Methods: We used a noninvasive Fourier-domain swept-source anterior-segment optical coherence tomography (AS-OCT) system to dynamically evaluate the shifts between the pIOL and anterior chamber structures under changing light conditions. For each eye assessed, we measured vault interval (VI), which we define based on central vault values in maximum mydriasis and in maximum miosis after light-induced changes in pupil diameter, and vault range (VR), which we define as the absolute difference between the VI values. Results: The pilot study sample comprised 39 eyes (23 patients) previously implanted (mean 107 +/- 156 days) with a pIOL. A significant difference in vault value was found when maximum and minimum pupil size was assessed under changing external light conditions (P < 0.001). The mean VR from scotopic (0.5 lux) to photopic (18,500 lux) light conditions was 167 +/- 70 mu m. Conclusions: Vault is continuously affected during movements of the pupil induced by external luminance. Translational Relevance: Quantifiable dynamic parameters VR and VI obtained with this AS-OCT device describe the position of the pIOL in the posterior chamber of the eye in a more accurate and real way than static vault measurements, and may contribute to improved understanding of the behavior of the pIOL in terms of safety.
引用
收藏
页数:7
相关论文
共 12 条
[1]   Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation [J].
Alfonso, Jose F. ;
Lisa, Carlos ;
Palacios, Ana ;
Fernandes, Paulo ;
Gonzalez-Meijome, Jose M. ;
Montes-Mico, Robert .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (06) :978-983
[2]   Imaging of posterior chamber phakic intraocular lens by optical coherence tomography [J].
Bechmann, M ;
Ullrich, S ;
Thiel, MJ ;
Kenyon, KR ;
Ludwig, K .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :360-363
[3]   Ultrasound biomicroscopy examination of posterior chamber phakic intraocular lens position [J].
García-Feijoó, J ;
Alfaro, IJ ;
Cuiña-Sardiña, R ;
Méndez-Hernandez, C ;
Del Castillo, JMB ;
García-Sánchez, J .
OPHTHALMOLOGY, 2003, 110 (01) :163-172
[4]   Changes in vaulting and the effect on refraction after phakic posterior chamber intraocular lens implantation [J].
Kamiya, Kazutaka ;
Shimizu, Kimiya ;
Kawamorita, Takushi .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (09) :1582-1586
[5]   Dynamic Vaulting Changes in V4c versus V4 Posterior Chamber Phakic Lenses Under Differing Lighting Conditions [J].
Lee, Hun ;
Kang, Sung Yong ;
Seo, Kyoung Yul ;
Chung, Byunghoon ;
Choi, Jin Young ;
Kim, Kyu Seo ;
Kim, Tae-Im .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (06) :1199-1204
[6]   Age-related behavior of posterior chamber lenses in myopic phakic eyes during accommodation measured by anterior segment partial coherence interferometry [J].
Lege, Barbara A. M. ;
Haigis, Wolfgang ;
Neuhann, Thomas F. ;
Bauer, Markus H. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (06) :999-1006
[7]   Anterior segment variations after posterior chamber phakic intraocular lens implantation in myopic eyes [J].
Lin, Haotian ;
Yan, Pisong ;
Yu, Keming ;
Luo, Lixia ;
Chen, Jingjing ;
Lin, Zhuoling ;
Chen, Weirong .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (05) :730-738
[8]   Changes in vaulting of myopic and toric implantable collamer lenses in different lighting conditions [J].
Lindland, Are ;
Heger, Hilde ;
Kugelberg, Maria ;
Zetterstrom, Charlotta .
ACTA OPHTHALMOLOGICA, 2012, 90 (08) :788-791
[9]   Vaulting of Myopic and Toric Implantable Collamer Lenses during Accommodation Measured with Visante Optical Coherence Tomography [J].
Lindland, Are ;
Heger, Hilde ;
Kugelberg, Maria ;
Zetterstrom, Charlotta .
OPHTHALMOLOGY, 2010, 117 (06) :1245-1250
[10]   Imaging the Iris with Swept-Source Optical Coherence Tomography: Relationship between Iris Volume and Primary Angle Closure [J].
Mak, Heather ;
Xu, Guihua ;
Leung, Christopher Kai-Shun .
OPHTHALMOLOGY, 2013, 120 (12) :2517-2524