The Effects of SENSE on PROPELLER Imaging

被引:21
作者
Chang, Yuchou [1 ]
Pipe, James G. [1 ]
Karis, John P. [1 ]
Gibbs, Wende N. [1 ]
Zwart, Nicholas R. [1 ]
Schaer, Michael [1 ,2 ,3 ]
机构
[1] Barrow Neurol Inst, Neuroimaging Res, Phoenix, AZ 85013 USA
[2] Philips Healthcare, Cleveland, OH USA
[3] Johns Hopkins Univ, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD USA
关键词
PROPELLER; SENSE; parallel imaging; motion correction; g-factor; sensitivity map extrapolation and rotation; MOTION CORRECTION; MRI; RECONSTRUCTION; TRAJECTORIES; CALIBRATION; TURBOPROP; GRAPPA; NOISE; BLADE; EPI;
D O I
10.1002/mrm.25557
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To study how sensitivity encoding (SENSE) impacts periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) image quality, including signal-to-noise ratio (SNR), robustness to motion, precision of motion estimation, and image quality. Methods: Five volunteers were imaged by three sets of scans. A rapid method for generating the g-factor map was proposed and validated via Monte Carlo simulations. Sensitivity maps were extrapolated to increase the area over which SENSE can be performed and therefore enhance the robustness to head motion. The precision of motion estimation of PROPELLER blades that are unfolded with these sensitivity maps was investigated. An interleaved R-factor PROPELLER sequence was used to acquire data with similar amounts of motion with and without SENSE acceleration. Two neuroradiologists independently and blindly compared 214 image pairs. Results: The proposed method of g-factor calculation was similar to that provided by the Monte Carlo methods. Extrapolation and rotation of the sensitivity maps allowed for continued robustness of SENSE unfolding in the presence of motion. SENSE-widened blades improved the precision of rotation and translation estimation. PROPELLER images with a SENSE factor of 3 outperformed the traditional PROPELLER images when reconstructing the same number of blades. Conclusion: SENSE not only accelerates PROPELLER but can also improve robustness and precision of head motion correction, which improves overall image quality even when SNR is lost due to acceleration. The reduction of SNR, as a penalty of acceleration, is characterized by the proposed g-factor method. (C) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:1598 / 1608
页数:11
相关论文
共 24 条
[1]   Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint [J].
Block, Kai Tobias ;
Uecker, Martin ;
Frahm, Jens .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (06) :1086-1098
[2]  
Chang S, 2008, P 16 ANN M ISMRM TOR
[3]  
Chang Y, 2014, P 22 ANN M ISMRM MIL
[4]   PROPELLER-EPI with parallel imaging using a circularly symmetric phased-array RF coil at 3.0 T: Application to high-resolution diffusion tensor imaging [J].
Chuang, Tzu-Chao ;
Huang, Teng-Yi ;
Lin, Fa-Hsuan ;
Wang, Fu-Nien ;
Juan, Chun-Jung ;
Chung, Hsiao-Wen ;
Chen, Cheng-Yu ;
Kwong, Kenneth K. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (06) :1352-1358
[5]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[6]   Regularized Iterative Reconstruction for Undersampled BLADE and Its Applications in Three-point Dixon Water-fat Separation [J].
He, Qiang ;
Weng, Dehe ;
Zhou, Xiaodong ;
Ni, Cheng .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (05) :1314-1325
[7]   Improved motion correction capabilities for fast spin echo T1 FLAIR propeller using non-Cartesian external calibration data driven parallel imaging [J].
Holmes, James H. ;
Beatty, Philip J. ;
Rowley, Howard A. ;
Li, Zhiqiang ;
Gaddipati, Ajeetkumar ;
Zhao, Xiaoli ;
Busse, Reed F. ;
Brittain, Jean H. .
MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (06) :1856-1865
[8]   A Parallel Imaging Technique Using Mutual Calibration for Split-Blade Diffusion-Weighted PROPELLER [J].
Li, Zhiqiang ;
Pipe, James G. ;
Aboussouan, Eric ;
Karis, John P. ;
Huo, Donglai .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (03) :638-644
[9]   Sensitivity Encoding Reconstruction With Nonlocal Total Variation Regularization [J].
Liang, Dong ;
Wang, Haifeng ;
Chang, Yuchou ;
Ying, Leslie .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (05) :1384-1392
[10]   Regularized Sensitivity Encoding (SENSE) Reconstruction Using Bregman Iterations [J].
Liu, Bo ;
King, Kevin ;
Steckner, Michael ;
Xie, Jun ;
Sheng, Jinhua ;
Ying, Leslie .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (01) :145-152