Biomaterials for orthopedic surgery in osteoporotic bone: A comparative study in osteopenic rats

被引:56
作者
Fini, M
Aldini, NN
Gandolfi, MG
Belmonte, MM
Giavaresi, G
Zucchini, C
DeBenedittis, A
Amati, S
Ravaglioli, A
Krayewski, A
Rocca, M
Guzzardella, GA
Biagini, G
Giardino, R
机构
[1] UNIV BOLOGNA,CHAIR SURG PATHOPHYSIOL,I-40126 BOLOGNA,ITALY
[2] UNIV BOLOGNA,INST HISTOL & GEN EMBRIOL,I-40126 BOLOGNA,ITALY
[3] UNIV ANCONA,DEPT MAT SCI,ANCONA,ITALY
[4] UNIV ANCONA,INST NORMAL HUMAN MORPHOL,ANCONA,ITALY
[5] CNR,INST TECHNOL RES CERAM,FAENZA,ITALY
[6] IST RIC CODIVILLA PUTTI IOR,SERV CHIRURG SPERIMENTALE,I-40136 BOLOGNA,ITALY
关键词
osteoporosis; renal failure; pathological fractures; biomaterials; osteointegration; hydroxyapatite (HA);
D O I
10.1177/039139889702000510
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To evaluate orthopedic devices in pathological bone, an experimental study was performed by implanting Titanium (Ti) and Hydroxyapatite (HA) rods in normal and osteopenic bone. Twenty-four rats were used: 12 were left intact (Control: C) while the other 12 were ovariectomized (OVX). After 4 months all the animals were submitted to the implant of Ti or HA in the left femoral condyle (Ti-C, HA-C Ti-OVX, HA-OVX). Two months later the animals were sacrificed for histomorphometric, ultrastructural and microanalytic studies. Our results show a significant difference between the Affinity Index (A.I.) of HA-C and Ti-C (77.0 +/- 7.4 vs 61.2 +/- 9.7) (p < 0.05). No significant differences were observed between the osteointegration of Ti-C and Ti-OVX (61.2 +/- 9.7 vs 48.2 +/- 6.7). Significant differences also exist between the osteointegration of HA-C and HA-OVX (77.0 7.4 vs 57.6 +/- 11.5) (p < 0.01). Microanalysis shows some modifications in Sulphur (S) concentration at the bone/biomaterial interface of the Ti-OVX group. Therefore our results confirmed the importance of biomaterials characteristics and of bone quality in osteointegration processes.
引用
收藏
页码:291 / 297
页数:7
相关论文
共 37 条
  • [1] CLINICAL AND RADIOLOGICAL FEATURES OF BONE-DISEASE IN LONG-TERM (15 OR MORE YEARS) HEMODIALYSIS-PATIENTS
    BEDANI, PL
    ORZINCOLO, C
    STORARI, A
    PERINI, L
    SOFFRITTI, S
    GILLI, P
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1993, 16 (10) : 704 - 710
  • [2] AMYLOID BONE-DISEASE AND HIGHLY PERMEABLE SYNTHETIC MEMBRANES
    BOCCALATTE, M
    PRATESI, G
    CALABRESE, G
    BIGNAZZI, A
    GONELLA, M
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1994, 17 (04) : 203 - 208
  • [3] Carlsson L, 1988, Int J Oral Maxillofac Implants, V3, P21
  • [4] HIP-FRACTURES IN THE ELDERLY - A WORLDWIDE PROJECTION
    COOPER, C
    CAMPION, G
    MELTON, LJ
    [J]. OSTEOPOROSIS INTERNATIONAL, 1992, 2 (06) : 285 - 289
  • [5] Epstein Sol, 1995, Current Opinion in Rheumatology, V7, P255, DOI 10.1097/00002281-199505000-00018
  • [6] FINI M, 1994, INT J ARTIF ORGANS, V17, P431
  • [7] GALLAGHERALLRED CR, 1994, PRIMARY CARE, V21, P175
  • [8] Gnudi S., 1993, Bollettino Societa Italiana Biologia Sperimentale, V69, P461
  • [9] GONZALES EA, 1995, NEPHROL DIAL TRANSPL, V10, pS15
  • [10] BONE-MINERAL DENSITY AFTER KIDNEY-TRANSPLANTATION - A CROSS-SECTIONAL, STUDY IN 190 GRAFT RECIPIENTS UP TO 20 YEARS AFTER TRANSPLANTATION
    GROTZ, WH
    MUNDINGER, FA
    GUGEL, B
    EXNER, VM
    KIRSTE, G
    SCHOLLMEYER, PJ
    [J]. TRANSPLANTATION, 1995, 59 (07) : 982 - 986