A Comparative Study of Two Types of Fuzzy Logic Controllers for Shunt Active Power Filters

被引:1
作者
Gadanayak, D. A. [1 ]
Majumder, Irani [1 ]
机构
[1] SOA Univ, Inst Tech Educ & Res, Dept Elect & Elect Engn, Bhubaneswar, Orissa, India
来源
SWARM, EVOLUTIONARY, AND MEMETIC COMPUTING, SEMCCO 2014 | 2015年 / 8947卷
关键词
Shunt active power filter; Mamdani type FLC; TSK type FLC; Indirect current control technique; Harmonics; Total harmonic distortion; Point of common coupling; MATLAB SimPowerSystems toolbox; QUALITY IMPROVEMENT; PERFORMANCE;
D O I
10.1007/978-3-319-20294-5_5
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In this work, two types of fuzzy logic controllers have been designed for a shunt active power filter and their steady state as well as transient performance has been compared to a conventional PI-controller. The performance of the various controllers has been judged on the basis of their ability to reduce Total Harmonic Distortion and their ability to reduce DC-link capacitor voltage settling time during load change. The second factor is important since it signifies controller's usefulness in rapid load changing industrial environment. Also, DC-link capacitor voltage rise at the time of decrease in load is taken as another factor for comparison as it might affect the voltage ratings of the power electronic devices used in the filter.
引用
收藏
页码:49 / 61
页数:13
相关论文
共 15 条
[1]   TRENDS IN ACTIVE POWER-LINE CONDITIONERS [J].
AKAGI, H .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1994, 9 (03) :263-268
[2]  
[Anonymous], 2012 IEEE INT C POW
[3]   Fuzzy Logic Controller Based Three-Phase Shunt Active Power Filter for Compensating Harmonics and Reactive Power under Unbalanced Mains Voltages [J].
Belaidi, R. ;
Haddouche, A. ;
Guendouz, H. .
TERRAGREEN 2012: CLEAN ENERGY SOLUTIONS FOR SUSTAINABLE ENVIRONMENT (CESSE), 2012, 18 :560-570
[4]   Parallel-Connected Shunt Hybrid Active Power Filters Operating at Different Switching Frequencies for Improved Performance [J].
Bhattacharya, Avik ;
Chakraborty, Chandan ;
Bhattacharya, Subhashish .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (11) :4007-4019
[5]   TS-fuzzy-controlled active power filter for load compensation [J].
Bhende, C. N. ;
Mishra, S. ;
Jain, S. K. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (03) :1459-1465
[6]  
Duke R. M., 1993, IEEE Transactions on Power Electronics, V8, P140, DOI 10.1109/63.223965
[7]   FUZZY CONTROLLERS - SYNTHESIS AND EQUIVALENCES [J].
GALICHET, S ;
FOULLOY, L .
IEEE TRANSACTIONS ON FUZZY SYSTEMS, 1995, 3 (02) :140-148
[8]   Fuzzy logic controlled shunt active power filter for power quality improvement [J].
Jain, SK ;
Agrawal, P ;
Gupta, HO .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2002, 149 (05) :317-328
[9]   Soft Computing Techniques for the Control of an Active Power Filter [J].
Kumar, Parmod ;
Mahajan, Alka .
IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (01) :452-461
[10]   TS-fuzzy controller for UPFC in a multimachine power system [J].
Mishra, S ;
Dash, PK ;
Panda, G .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2000, 147 (01) :15-22