Non-rigid Deformation Pipeline for Compensation of Superficial Brain Shift

被引:0
作者
Marreiros, Filipe M. M. [1 ,2 ,3 ,4 ]
Rossitti, Sandro [1 ,2 ,3 ,4 ]
Wang, Chunliang [1 ,2 ,3 ,4 ]
Smedby, Orjan [1 ,2 ,3 ,4 ]
机构
[1] Linkoping Univ, Ctr Med Image Sci & Visualizat CMIV, S-58183 Linkoping, Sweden
[2] Linkoping Univ, MIT, ITN, S-58183 Linkoping, Sweden
[3] Linkoping Univ, Dept Radiol, S-58183 Linkoping, Sweden
[4] Cty Council Ostergotland, Dept Neurosurg, S-58183 Linkoping, Sweden
来源
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2013, PT II | 2013年 / 8150卷
关键词
THIN-PLATE SPLINES; REGISTRATION; RECOVERY;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The correct visualization of anatomical structures is a critical component of neurosurgical navigation systems, to guide the surgeon to the areas of interest as well as to avoid brain damage. A major challenge for neuronavigation systems is the brain shift, or deformation of the exposed brain in comparison to preoperative Magnetic Resonance (MR) image sets. In this work paper, a non-rigid deformation pipeline is proposed for brain shift compensation of preoperative imaging datasets using superficial blood vessels as landmarks. The input was preoperative and intraoperative 3D image sets of superficial vessel centerlines. The intraoperative vessels (obtained using 3 Near-Infrared cameras) were registered and aligned with preoperative Magnetic Resonance Angiography vessel centerlines using manual interaction for the rigid transformation and, for the non-rigid transformation, the non-rigid point set registration method Coherent Point Drift. The rigid registration transforms the intraoperative points from the camera coordinate system to the preoperative MR coordinate system, and the non-rigid registration deals with local transformations in the MR coordinate system. Finally, the generation of a new deformed volume is achieved with the Thin-Plate Spline (TPS) method using as control points the matches in the MR coordinate system found in the previous step. The method was tested in a rabbit brain exposed via craniotomy, where deformations were produced by a balloon inserted into the brain. There was a good correlation between the real state of the brain and the deformed volume obtained using the pipeline. Maximum displacements were approximately 4.0 mm for the exposed brain alone, and 6.7 mm after balloon inflation.
引用
收藏
页码:141 / 148
页数:8
相关论文
共 15 条
  • [2] Chui H., 2000, IEEE C COMP VIS PATT, V2, P2262
  • [3] Robust nonrigid registration to capture brain shift from intraoperative MRI
    Clatz, O
    Delingette, H
    Talos, IF
    Golby, AJ
    Kikinis, R
    Jolesz, FA
    Ayache, N
    Warfield, SK
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (11) : 1417 - 1427
  • [4] D'Apuzzo D., 2008, P SPIE IS T ELECT IM, V6805
  • [5] Image-Guided Intraoperative Cortical Deformation Recovery Using Game Theory: Application to Neocortical Epilepsy Surgery
    DeLorenzo, Christine
    Papademetris, Xenophon
    Staib, Lawrence H.
    Vives, Kenneth P.
    Spencer, Dennis D.
    Duncan, James S.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (02) : 322 - 338
  • [6] Semiautomatic Registration of Pre- and Postbrain Tumor Resection Laser Range Data: Method and Validation
    Ding, Siyi
    Miga, Michael I.
    Noble, Jack H.
    Cao, Aize
    Dumpuri, Prashanth
    Thompson, Reid C.
    Dawant, Benoit M.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (03) : 770 - 780
  • [7] Hsieh C., 2012, INT J INTELLIGENT IN, V3
  • [8] 3D shape recovery of a newborn skull using thin-plate splines
    Lapeer, RJA
    Prager, RW
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2000, 24 (03) : 193 - 204
  • [9] Marreiros F., 2013, P CARS 2013 IM PROC
  • [10] Point Set Registration: Coherent Point Drift
    Myronenko, Andriy
    Song, Xubo
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2010, 32 (12) : 2262 - 2275