A rapid and sensitive method based on magnetic beads for the detection of hepatitis B virus surface antigen in human serum

被引:13
作者
Ren, Zhi-Qi [1 ]
Liu, Tian-Cai [1 ]
Hou, Jing-Yuan [1 ]
Chen, Mei-Jun [1 ]
Chen, Zhen-Hua [1 ]
Lin, Guan-Feng [1 ]
Wu, Ying-Song [1 ]
机构
[1] Southern Med Univ, Inst Antibody Engn, Sch Biotechnol, Guangzhou 510515, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
magnetic beads; time-resolved fluoroimmunoassay; hepatitis B surface antibody; hepatitis B virus; rapid and sensitive detection; TIME-RESOLVED FLUOROIMMUNOASSAY; ENZYME-IMMUNOASSAY; MANAGEMENT; DISEASE; SAMPLES; ASSAY;
D O I
10.1002/bio.2587
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Current clinically assays, such as enzyme-linked immunosorbent assay and chemiluminescence immunoassay, for hepatitis B surface antigen (HBsAg) are inferior in terms of either sensitivity and accuracy or rapid and high-throughput analysis. A novel assay based on magnetic beads and time-resolved fluoroimmunoassay was developed for the quantitative determination of HBsAg in human serum. HBsAg was captured using two types of anti-HBsAg monoclonal antibodies (B028, S015) immobilized on to magnetic beads and detected using europium-labeled anti-HBsAg polyclonal detection antibody. Finally, the assay yielded a high sensitivity (0.02IU/mL) and a wide dynamic range (0.02-700IU/mL) for HBsAg when performed under optimal conditions. Satisfactory accuracy, recovery and specificity were also demonstrated. The intra- and interassay coefficients of variation were 4.7-8.7% and 3.8-7.5%, respectively. The performance of this assay was further assessed against a well-established commercial chemiluminescence immunoassay kit with 399 clinical serum samples. It was revealed that the test results for the two methods were in good correlation (Y=1.182X - 0.017, R=0.989). In the current study, we demonstrated that this novel time-resolved fluoroimmunoassay could be used: as a highly sensitive, automated and high-throughput immunoassay for the diagnosis of acute or chronic hepatitis B virus infection; for the screening of blood or organ donors; and for the surveillance of persons at risk of acquiring or transmitting hepatitis B virus. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:591 / 597
页数:7
相关论文
共 35 条
[1]  
Bettazzi F, 2013, BIOANALYSIS, V5, P11, DOI [10.4155/BIO.12.293, 10.4155/bio.12.293]
[2]   Immunomagnetic bead-based cell concentration microdevice for dilute pathogen detection [J].
Beyor, Nathaniel ;
Seo, Tae Seok ;
Liu, Peng ;
Mathies, Richard A. .
BIOMEDICAL MICRODEVICES, 2008, 10 (06) :909-917
[3]   Hepatitis B surface antigen seroclearance during chronic HBV infection [J].
Chu, Chia-Ming ;
Liaw, Yun-Fan .
ANTIVIRAL THERAPY, 2010, 15 (02) :133-143
[4]   Development and Validation of a Novel Diagnostic Test for Human Brucellosis Using a Glyco-engineered Antigen Coupled to Magnetic Beads [J].
Ciocchini, Andres E. ;
Rey Serantes, Diego A. ;
Melli, Luciano J. ;
Iwashkiw, Jeremy A. ;
Deodato, Bettina ;
Wallach, Jorge ;
Feldman, Mario F. ;
Ugalde, Juan E. ;
Comerci, Diego J. .
PLOS NEGLECTED TROPICAL DISEASES, 2013, 7 (02)
[5]   Development and evaluation of a rapid immunomagnetic bead assay for the detection of classical swine fever virus antigen [J].
Conlan, James V. ;
Khounsy, Syseng ;
Blacksell, Stuart D. ;
Morrissy, Christopher J. ;
Wilks, Colin R. ;
Gleeson, Laurence J. .
TROPICAL ANIMAL HEALTH AND PRODUCTION, 2009, 41 (06) :913-920
[6]   Development of an immunomagnetic bead-immunoliposome fluorescence assay for rapid detection of Escherichia coli O157:H7 in aqueous samples and comparison of the assay with a standard microbiological method [J].
DeCory, TR ;
Durst, RA ;
Zimmerman, SJ ;
Garringer, LA ;
Paluca, G ;
DeCory, HH ;
Montagna, RA .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2005, 71 (04) :1856-1864
[7]   Hepatitis B virus: From diagnosis to treatment [J].
Deny, P. ;
Zoulim, F. .
PATHOLOGIE BIOLOGIE, 2010, 58 (04) :245-253
[8]   INCREASED RISK FOR LETHAL FORMS OF LIVER-DISEASE AMONG HBSAG-POSITIVE BLOOD-DONORS IN THE UNITED-STATES [J].
DODD, RY ;
NATH, N .
JOURNAL OF VIROLOGICAL METHODS, 1987, 17 (1-2) :81-94
[9]   Development of an immunomagnetic bead-based time-resolved fluorescence immunoassay for rapid determination of levels of carcinoembryonic antigen in human serum [J].
Hou, Jing-Yuan ;
Liu, Tian-Cai ;
Lin, Guan-Feng ;
Li, Zhi-Xiong ;
Zou, Li-Ping ;
Li, Ming ;
Wu, Ying-Song .
ANALYTICA CHIMICA ACTA, 2012, 734 :93-98
[10]   Ultrasensitive detection of pepsinogen I and pepsinogen II by a time-resolved fluoroimmunoassay and its preliminary clinical applications [J].
Huang, B ;
Xiao, HL ;
Zhang, XR ;
Zhu, L ;
Liu, HY ;
Jin, J .
ANALYTICA CHIMICA ACTA, 2006, 571 (01) :74-78