High Atomic Number Contrast Media Offer Potential for Radiation Dose Reduction in Contrast-Enhanced Computed Tomography

被引:29
作者
Roessler, Ann-Christin [1 ]
Hupfer, Martin [1 ]
Kolditz, Daniel [1 ]
Jost, Gregor [2 ]
Pietsch, Hubertus [2 ]
Kalender, Willi A. [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
[2] Bayer Healthcare, Berlin, Germany
关键词
high atomic number contrast media; contrast-enhanced CT; iodine; tungsten; dose reduction; hafnium; LIVER METASTASES; AGENTS;
D O I
10.1097/RLI.0000000000000232
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives Spectral optimization of x-ray computed tomography (CT) has led to substantial radiation dose reduction in contrast-enhanced CT studies using standard iodinated contrast media. The purpose of this study was to analyze the potential for further dose reduction using high-atomic-number elements such as hafnium and tungsten. As in previous studies, spectra were determined for which the patient dose necessary to provide a given contrast-to-noise ratio (CNR) is minimized. Materials and Methods We used 2 different quasi-anthropomorphic phantoms representing the liver cross-section of a normal adult and an obese adult patient with the lateral widths of 360 and 460 mm and anterior-posterior heights of 200 and 300 mm, respectively. We simulated and measured on 2 different scanners with x-ray spectra from 80 to 140 kV and from 70 to 150 kV, respectively. We determined the contrast for iodine-, hafnium-, and tungsten-based contrast media, the noise, and 3-dimensional dose distributions at all available tube voltages by measurements and by simulations. The dose-weighted CNR was determined as optimization parameter. Results Simulations and measurements were in good agreement regarding their dependence on energy for all parameters investigated. Hafnium provided the best performance for normal and for obese patient phantoms, indicating a dose reduction potential of 30% for normal and 50% for obese patients at 120 kV compared with iodine; this advantage increased further with higher kV values. Dose-weighted CNR values for tungsten were always slightly below the hafnium results. Iodine proved to be the superior choice at voltage values of 80 kV and below. Discussion Hafnium and tungsten both seem to be candidates for contrast-medium-enhanced CT of normal and obese adult patients with strongly reduced radiation dose at unimpaired image quality. Computed tomography examinations of obese patients will decrease in dose for higher kV values.
引用
收藏
页码:249 / 254
页数:6
相关论文
共 9 条
[1]   Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography [J].
Deak, Paul ;
van Straten, Marcel ;
Shrimpton, Paul C. ;
Zankl, Maria ;
Kalender, Willi A. .
EUROPEAN RADIOLOGY, 2008, 18 (04) :759-772
[2]   Zr- and Hf-based nanoscale metal-organic frameworks as contrast agents for computed tomography [J].
deKrafft, Kathryn E. ;
Boyle, William S. ;
Burk, Laurel M. ;
Zhou, Otto Z. ;
Lin, Wenbin .
JOURNAL OF MATERIALS CHEMISTRY, 2012, 22 (35) :18139-18144
[3]   Application- and patient size-dependent optimization of x-ray spectra for CT [J].
Kalender, Willi A. ;
Deak, Paul ;
Kellermeier, Markus ;
van Straten, Marcel ;
Vollmar, Sabrina V. .
MEDICAL PHYSICS, 2009, 36 (03) :993-1007
[4]   Potential of high-Z contrast agents in clinical contrast-enhanced computed tomography [J].
Nowak, Tristan ;
Hupfer, Martin ;
Brauweiler, Robert ;
Eisa, Fabian ;
Kalender, Willi A. .
MEDICAL PHYSICS, 2011, 38 (12) :6469-6482
[5]   Current Status of Imaging and Emerging Techniques to Evaluate Liver Metastases From Colorectal Carcinoma [J].
Sahani, Dushyant V. ;
Bajwa, Mohammad Ali ;
Andrabi, Yasir ;
Bajpai, Surabhi ;
Cusack, James C. .
ANNALS OF SURGERY, 2014, 259 (05) :861-872
[6]   New Tungsten Cluster Based Contrast Agents for X-ray Computed Tomography [J].
Suelzle, Detlev ;
Bauser, Marcus ;
Frenzel, Thomas ;
Jost, Gregor ;
Pietsch, Hubertus ;
Schaefer, Martina ;
Berger, Markus ;
Hassfeld, Jorma ;
Schmitt-Willich, Heribert .
JOURNAL OF CLUSTER SCIENCE, 2015, 26 (01) :111-118
[7]   An update on chemotherapy of colorectal liver metastases [J].
Wang, Chen-Chen ;
Li, Jin .
WORLD JOURNAL OF GASTROENTEROLOGY, 2012, 18 (01) :25-33
[8]   Semiempirical analysis of materials' elemental composition to formulate tissue-equivalent materials: a preliminary study [J].
Yohannes, Indra ;
Kolditz, Daniel ;
Kalender, Willi A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (10) :2963-2977
[9]   Metal-based X-ray contrast media [J].
Yu, SB ;
Watson, AD .
CHEMICAL REVIEWS, 1999, 99 (09) :2353-2377