Linearization of CMOS Hot-Electron Injectors for Self-Powered Monitoring of Biomechanical Strain Variations

被引:8
|
作者
Zhou, Liang [1 ]
Chakrabartty, Shantanu [1 ]
机构
[1] Washington Univ, Dept Comp Sci & Engn, St Louis, MO 63130 USA
基金
美国国家科学基金会;
关键词
Biomechanics; health and usage monitoring; hot-electron injection; piezo-floating-gate; self-powered sensors; signal compression; FEASIBILITY; IMPLANTS; SENSORS;
D O I
10.1109/TBCAS.2016.2605444
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In our previous work we demonstrated that by eliminating regulation and rectification modules from the energy harvesting pathway, the minimum activation power of a piezoelectricity-driven hot-electron injector (p-HEI) can be reduced down to a few nanowatts. As a result the p-HEI device could be used for self-powered, in-vivo recording of biomechanical strain variations. However, for large magnitudes of input strain energy, the response of the modified p-HEI sensor was found to be quasi-linear with respect to the number of loading cycles, which made the calibration of the sensor difficult across a wide variety of biomedical applications. In this paper we propose a compensation circuit that is able to linearize the response of the p-HEI injector over a wide range of input power while maintaining a low activation threshold. The compensation circuit uses a combination of a storage capacitor and a non-linear resistor which produces a compressive input-output response required for linearization. Using prototypes fabricated in a 0.5-mu m bulk CMOS process we validate the functionality of the injector and demonstrate that it can achieve a linear injection response for input power ranging from 5 nW to 1.5 mu W.
引用
收藏
页码:446 / 454
页数:9
相关论文
共 40 条
  • [1] A 5 nW Quasi-Linear CMOS Hot-Electron Injector for Self-Powered Monitoring of Biomechanical Strain Variations
    Zhou, Liang
    Abraham, Adam C.
    Tang, Simon Y.
    Chakrabartty, Shantanu
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2016, 10 (06) : 1143 - 1151
  • [2] Approaching the Limits of Piezoelectricity driven Hot-electron Injection for Self-powered in vivo Monitoring of Micro-strain Variations
    Zhou, Liang
    Abraham, Adam C.
    Tang, Simon Y.
    Chakrabartty, Shantanu
    2016 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2016, : 1810 - 1813
  • [3] Self-powered CMOS Impact-rate Monitors for Biomechanical Implants
    Huang, Chenling
    Chakrabartty, Shantanu
    2008 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE - INTELLIGENT BIOMEDICAL SYSTEMS (BIOCAS), 2008, : 385 - 388
  • [4] Simultaneous Biomechanical and Biochemical Monitoring for Self-Powered Breath Analysis
    Liu, Bohao
    Libanori, Alberto
    Zhou, Yihao
    Xiao, Xiao
    Xie, Guangzhong
    Zhao, Xun
    Su, Yuanjie
    Wang, Si
    Yuan, Zhen
    Duan, Zaihua
    Liang, Junge
    Jiang, Yadong
    Tai, Huiling
    Chen, Jun
    ACS APPLIED MATERIALS & INTERFACES, 2022, 14 (05) : 7301 - 7310
  • [5] Compact self-powered CMOS strain-rate monitoring circuit for piezoelectric energy scavengers
    Huang, C.
    Chakrabartty, S.
    ELECTRONICS LETTERS, 2011, 47 (04) : 277 - +
  • [6] Sub-Hz Self-powered Sensing based on Mechanical-buckling driven Hot-electron Injection
    Lajnef, Nizar
    Burgueno, Rigoberto
    Borchani, Wassim
    Chakrabartty, Shantanu
    2014 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2014, : 670 - 673
  • [7] Self-Powered, Hybrid, Multifunctional Sensor for a Human Biomechanical Monitoring Device
    Lu, Yeh Hsin
    Lo, Hsiao Han
    Wang, Jie
    Lee, Tien Hsi
    Fuh, Yiin Kuen
    APPLIED SCIENCES-BASEL, 2021, 11 (02): : 1 - 12
  • [8] Piezo-powered floating gate injector for self-powered fatigue monitoring in biomechanical implants
    Lajnef, Nizar
    Chakrabartty, Shantanu
    Elvin, Niell
    Elvin, Alex
    2007 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-11, 2007, : 89 - +
  • [9] Design of a Self-powered Load Monitoring System for Hot Spot Applications
    Lin, Y.
    Taya, M.
    Ihn, J. B.
    STRUCTURAL HEALTH MONITORING 2011: CONDITION-BASED MAINTENANCE AND INTELLIGENT STRUCTURES, VOL 1, 2011, : 333 - +
  • [10] Self-Powered Piezoionic Strain Sensor toward the Monitoring of Human Activities
    Liu, Yang
    Hu, Ying
    Zhao, Jingjing
    Wu, Guan
    Tao, Xiaoming
    Chen, Wei
    SMALL, 2016, 12 (36) : 5074 - 5080