Blood gas values in clamped and unclamped umbilical cord at birth

被引:21
作者
Di Tommaso, Mariarosaria [1 ]
Seravalli, Viola [1 ]
Martini, Irene [1 ]
La Torre, Pasquale [1 ]
Dani, Carlo [2 ]
机构
[1] Univ Florence, Dept Hlth Sci, I-50134 Florence, Italy
[2] Univ Florence, Dept Neurosci Psychol Drug Res & Child Hlth, I-50134 Florence, Italy
关键词
Cord blood gas; Cord clamping; Fetal oxygenation; Acid-base status; ARTERY BLOOD; IRON STATUS; ACID-BASE; HEMORRHAGE; INFANTS; TIME;
D O I
10.1016/j.earlhumdev.2014.03.010
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Aim: To determine the reliability of the cord blood gas analysis on the unclamped cord compared to the standard technique of sampling on double clamped cord. Study design: Prospective observational study conducted on 46 singleton neonates vaginally delivered at term. Matched pairs of umbilical artery and vein blood samples were collected from undamped cord within 90 s after birth and from the same cord after clamping, with the clamping occurring immediately after the first blood collection. A blood gas analysis was performed on each collected sample. Outcome measures: Arterial and venous blood samples were analyzed for pH, PO2, pCO(2), SaO(2), hemoglobin concentration (ctHb) and base excess (BE). The values were compared between the two groups (clamped vs unclamped) using a Wilcoxon test. Results: No significant difference was found in pH, PO2, pCO(2), SaO(2) and ctHb values on arterial blood between unclamped and clamped cord. The only significant difference was related to BE (p < 0.001). For the venous blood, the values of pH, PO2, pCO(2) were comparable between unclamped and clamped cord, while the values of SaO(2), ctHb and BE were significantly different (p < 0.05). Conclusion: No significant difference was found in almost all the arterial blood gas parameters and in the main venous blood gas parameters between unclamped and clamped cord. Sampling of cord blood for gas analysis may be performed on the unclamped cord right after birth without reducing the accuracy of the analysis. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:523 / 525
页数:3
相关论文
共 50 条
  • [41] Sampling of umbilical cord blood gases after operative deliveries
    Altanis, S.
    Elrahman, I.
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2007, 27 (06) : 571 - 573
  • [42] Relationship Between Oxygen Saturation and Umbilical Cord pH Immediately After Birth
    Uslu, Sinan
    Bulbul, Ali
    Can, Emrah
    Zubarioglu, Umut
    Salihoglu, Ozgul
    Nuhoglu, Asiye
    PEDIATRICS AND NEONATOLOGY, 2012, 53 (06) : 340 - 345
  • [43] Umbilical cord milking for neonates who are depressed at birth: a randomized trial of feasibility
    Girish, Meenakshi
    Jain, Vinita
    Dhokane, Rohinie
    Gondhali, Shital B.
    Vaidya, Ashish
    Aghai, Zubair H.
    JOURNAL OF PERINATOLOGY, 2018, 38 (09) : 1190 - 1196
  • [44] Predicting Fetal Acidemia Using Umbilical Venous Cord Gas Parameters
    Cantu, Jessica
    Szychowski, Jeff M.
    Li, Xuelin
    Biggio, Joseph
    Edwards, Rodney K.
    Andrews, William
    Tita, Alan T. N.
    OBSTETRICS AND GYNECOLOGY, 2014, 124 (05) : 926 - 932
  • [45] Umbilical cord blood gases: probability of arterial or venous source in acidemia
    Monneret, Denis
    Stavis, Robert L.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (01) : 112 - 122
  • [46] Umbilical Cord Blood Lead Level Disparities between Flint and Detroit
    Hanna-Attisha, Mona
    Gonuguntla, Ashweena
    Peart, Nadine
    LaChance, Jenny
    Taylor, D. Kay
    Chawla, Sanjay
    AMERICAN JOURNAL OF PERINATOLOGY, 2021, 38 : E26 - E32
  • [47] Efficacy and Safety of Umbilical Cord Milking at Birth A Systematic Review and Meta-analysis
    Al-Wassia, Heidi
    Shah, Prakesh S.
    JAMA PEDIATRICS, 2015, 169 (01) : 18 - 25
  • [48] Optimized multiparametric immunophenotyping of umbilical cord blood cells by flow cytometry
    Basford, Christina
    Forraz, Nico
    McGuckin, Colin
    NATURE PROTOCOLS, 2010, 5 (07) : 1337 - 1346
  • [49] Changes in Cord Arterial Blood Gas Parameters by the Onset of Spontaneous Respiration during Delayed Cord Clamping
    Koh, Ji Hye
    Kim, Hyo-Eun
    Choi, Suhyoon
    Ahn, Jun-Woo
    CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 2023, 50 (07)
  • [50] The effect of delayed umbilical cord clamping on cord blood gas analysis in vaginal and caesarean-delivered term newborns without fetal distress: a prospective observational study
    Giovannini, N.
    Crippa, B. L.
    Denaro, E.
    Raffaeli, G.
    Cortesi, V.
    Consonni, D.
    Cetera, G. E.
    Parazzini, F.
    Ferrazzi, E.
    Mosca, F.
    Ghirardello, S.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2020, 127 (03) : 405 - 413