Blood gas values in clamped and unclamped umbilical cord at birth

被引:21
|
作者
Di Tommaso, Mariarosaria [1 ]
Seravalli, Viola [1 ]
Martini, Irene [1 ]
La Torre, Pasquale [1 ]
Dani, Carlo [2 ]
机构
[1] Univ Florence, Dept Hlth Sci, I-50134 Florence, Italy
[2] Univ Florence, Dept Neurosci Psychol Drug Res & Child Hlth, I-50134 Florence, Italy
关键词
Cord blood gas; Cord clamping; Fetal oxygenation; Acid-base status; ARTERY BLOOD; IRON STATUS; ACID-BASE; HEMORRHAGE; INFANTS; TIME;
D O I
10.1016/j.earlhumdev.2014.03.010
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Aim: To determine the reliability of the cord blood gas analysis on the unclamped cord compared to the standard technique of sampling on double clamped cord. Study design: Prospective observational study conducted on 46 singleton neonates vaginally delivered at term. Matched pairs of umbilical artery and vein blood samples were collected from undamped cord within 90 s after birth and from the same cord after clamping, with the clamping occurring immediately after the first blood collection. A blood gas analysis was performed on each collected sample. Outcome measures: Arterial and venous blood samples were analyzed for pH, PO2, pCO(2), SaO(2), hemoglobin concentration (ctHb) and base excess (BE). The values were compared between the two groups (clamped vs unclamped) using a Wilcoxon test. Results: No significant difference was found in pH, PO2, pCO(2), SaO(2) and ctHb values on arterial blood between unclamped and clamped cord. The only significant difference was related to BE (p < 0.001). For the venous blood, the values of pH, PO2, pCO(2) were comparable between unclamped and clamped cord, while the values of SaO(2), ctHb and BE were significantly different (p < 0.05). Conclusion: No significant difference was found in almost all the arterial blood gas parameters and in the main venous blood gas parameters between unclamped and clamped cord. Sampling of cord blood for gas analysis may be performed on the unclamped cord right after birth without reducing the accuracy of the analysis. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:523 / 525
页数:3
相关论文
共 50 条
  • [21] The Effect of Maternal Pulmonary Function Test Parameters on Umbilical Cord Blood Gas and the Duration of Labor
    Caltekin, Melike Demir
    Onat, Taylan
    Kirmizi, Demet Aydogan
    Baser, Emre
    Intepe, Yavuz Selim
    Kara, Mustafa
    Yalvac, Ethem Serdar
    ZEITSCHRIFT FUR GEBURTSHILFE UND NEONATOLOGIE, 2021, 225 (04): : 341 - 345
  • [22] Mercury, Lead, and Cadmium in Umbilical Cord Blood
    King, Ewa
    Shih, Grace
    Ratnapradipa, Dhitinut
    Quilliam, Daniela N.
    Morton, John
    Magee, Susanna R.
    JOURNAL OF ENVIRONMENTAL HEALTH, 2013, 75 (06) : 38 - 43
  • [23] A Comparison of Strategies for Managing the Umbilical Cord at Birth in Preterm Infants
    El-Naggar, Walid
    Afifi, Jehier
    Dorling, Jon
    Bodani, Jaya
    Cieslak, Zenon
    Canning, Rody
    Ye, Xiang Y.
    Crane, Joan
    Lee, Shoo K.
    Shah, Prakesh S.
    JOURNAL OF PEDIATRICS, 2020, 225 : 58 - +
  • [24] Evaluation of selection criteria for validating paired umbilical cord blood gas samples: an observational study
    White, C. R. H.
    Doherty, D. A.
    Kohan, R.
    Newnham, J. P.
    Pennell, C. E.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2012, 119 (07) : 857 - 865
  • [25] Effects of delayed compared with early umbilical cord clamping on maternal postpartum hemorrhage and cord blood gas sampling: a randomized trial
    Andersson, Ola
    Hellstrom-Westas, Lena
    Andersson, Dan
    Clausen, Jesper
    Domellof, Magnus
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2013, 92 (05) : 567 - 574
  • [26] Gestational age impacts birth to placental weight ratio and umbilical cord oxygen values with implications for the fetal oxygen margin of safety
    Richardson, Bryan S.
    de Vrijer, Barbra
    Brown, Hilary K.
    Stitt, Larry
    Choo, Sheryl
    Regnault, Timothy R. H.
    EARLY HUMAN DEVELOPMENT, 2022, 164
  • [27] Umbilical cord blood acid-base and gas analysis after early versus delayed cord clamping in neonates at term
    De Paco, Catalina
    Florido, Jesus
    Carmen Garrido, Mari
    Prados, Sonia
    Navarrete, Luis
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2011, 283 (05) : 1011 - 1014
  • [28] The effects of time and temperature on umbilical cord gas analysis
    Fan, Isabella
    Hiersch, Liran
    Belov, Yekaterina
    Amikam, Uri
    Tzur, Yossi
    Hershkovitz, Gal
    Sindel, Ofra
    Alpern, Sharon
    Segal, Roy
    Dangot, Ayelet
    Many, Ariel
    Yogev, Yariv
    Ashwal, Eran
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2022, 35 (22) : 4358 - 4364
  • [29] Guided training has a beneficial effect on umbilical cord blood sampling quality
    Kugelman, Nir
    Bart, Yossi
    Sghier, Amir
    Kedar, Reuven
    Bardicef, Mordehai
    Lavie, Ofer
    Zilberlicht, Ariel
    Sagi-Dain, Lena
    Damti, Amit
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2021, 266 : 31 - 35
  • [30] Risk factors of incomplete Apgar score and umbilical cord blood gas analysis: a retrospective observational study
    van Tetering, Anne A. C.
    de Ven, Joost van
    Fransen, Annemarie F.
    Dieleman, Jeanne P.
    Heimel, Pieter J. van Runnard
    Oei, S. Guid
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2017, 30 (21) : 2539 - 2544