Blood gas values in clamped and unclamped umbilical cord at birth

被引:21
|
作者
Di Tommaso, Mariarosaria [1 ]
Seravalli, Viola [1 ]
Martini, Irene [1 ]
La Torre, Pasquale [1 ]
Dani, Carlo [2 ]
机构
[1] Univ Florence, Dept Hlth Sci, I-50134 Florence, Italy
[2] Univ Florence, Dept Neurosci Psychol Drug Res & Child Hlth, I-50134 Florence, Italy
关键词
Cord blood gas; Cord clamping; Fetal oxygenation; Acid-base status; ARTERY BLOOD; IRON STATUS; ACID-BASE; HEMORRHAGE; INFANTS; TIME;
D O I
10.1016/j.earlhumdev.2014.03.010
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Aim: To determine the reliability of the cord blood gas analysis on the unclamped cord compared to the standard technique of sampling on double clamped cord. Study design: Prospective observational study conducted on 46 singleton neonates vaginally delivered at term. Matched pairs of umbilical artery and vein blood samples were collected from undamped cord within 90 s after birth and from the same cord after clamping, with the clamping occurring immediately after the first blood collection. A blood gas analysis was performed on each collected sample. Outcome measures: Arterial and venous blood samples were analyzed for pH, PO2, pCO(2), SaO(2), hemoglobin concentration (ctHb) and base excess (BE). The values were compared between the two groups (clamped vs unclamped) using a Wilcoxon test. Results: No significant difference was found in pH, PO2, pCO(2), SaO(2) and ctHb values on arterial blood between unclamped and clamped cord. The only significant difference was related to BE (p < 0.001). For the venous blood, the values of pH, PO2, pCO(2) were comparable between unclamped and clamped cord, while the values of SaO(2), ctHb and BE were significantly different (p < 0.05). Conclusion: No significant difference was found in almost all the arterial blood gas parameters and in the main venous blood gas parameters between unclamped and clamped cord. Sampling of cord blood for gas analysis may be performed on the unclamped cord right after birth without reducing the accuracy of the analysis. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:523 / 525
页数:3
相关论文
共 50 条
  • [1] The effect of clamped and unclamped umbilical cord samples on blood gas analysis
    Colciago, Elisabetta
    Fumagalli, Simona
    Ciarmoli, Elena
    Antolini, Laura
    Nespoli, Antonella
    Mastrolia, Salvatore Andrea
    Tagliabue, Paolo Emilio
    Furlan, Chiara
    Manganini, Cristina
    Vergani, Patrizia
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2021, 304 (06) : 1493 - 1499
  • [2] The effect of clamped and unclamped umbilical cord samples on blood gas analysis
    Elisabetta Colciago
    Simona Fumagalli
    Elena Ciarmoli
    Laura Antolini
    Antonella Nespoli
    Salvatore Andrea Mastrolia
    Paolo Emilio Tagliabue
    Chiara Furlan
    Cristina Manganini
    Patrizia Vergani
    Archives of Gynecology and Obstetrics, 2021, 304 : 1493 - 1499
  • [3] Effect of Delayed Cord Clamping on Umbilical Blood Gas Values in Term Newborns A Systematic Review
    Nudelman, Matthew J. R.
    Belogolovsky, Esther
    Jegatheesan, Priya
    Govindaswami, Balaji
    Song, Dongli
    OBSTETRICS AND GYNECOLOGY, 2020, 135 (03) : 576 - 582
  • [5] Umbilical cord blood gas analysis at delivery
    Thorp, JA
    Dildy, GA
    Yeomans, ER
    Meyer, BA
    Parisi, VM
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1996, 175 (03) : 517 - 522
  • [6] Association of umbilical cord blood gas values with mortality and severe neurologic injury in preterm neonates &lt;29 weeks' gestation: a national cohort study
    Shah, Prakesh S.
    Barrett, Jon
    Claveau, Martine
    Cieslak, Zenon
    Makary, Hale
    Monterrosa, Luis
    Sherlock, Rebecca
    Yang, Jie
    McDonald, Sarah D.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2022, 227 (01) : 85.e1 - 85.e10
  • [7] Arterio-venous blood gas Δvalues for validation of umbilical cord blood samples at birth are not only biased by sample mix ups but also affected by clinical factors
    Mokarami, Parisa
    Wiberg, Nana
    Kallen, Karin
    Olofsson, Per
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2019, 98 (02) : 167 - 175
  • [8] Systematic umbilical cord blood analysis at birth: Feasibility and reliability in a French labour ward
    Ernst, D.
    Clerc, J.
    Decullier, E.
    Gavanier, G.
    Dupuis, O.
    GYNECOLOGIE OBSTETRIQUE & FERTILITE, 2012, 40 (10): : 566 - 571
  • [9] Umbilical blood gas analysis in preeclamptic versus healthy pregnancies with preterm birth
    Sheikh, Mahdi
    Zoham, Mojdeh Habibi
    Hantoushzadeh, Sedigheh
    Shariat, Mamak
    Dalili, Hosein
    Amini, Elaheh
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2016, 29 (15) : 2548 - 2553
  • [10] Umbilical Cord Blood Gas Analysis after fetal distress
    Raicevic, S.
    Kljakic, D.
    Popivoda, Z.
    Grdinic, A.
    Marijanovic, G.
    Vukcevic, G.
    ADVANCES IN PERINATAL MEDICINE, 2010, : 623 - +