共 8 条
First study of passive sampling to monitor short-chain chlorinated paraffins in water: Comparing capabilities of Chemcatcher® and silicone rubber samplers
被引:5
|作者:
Godere, Mathilde
[1
]
Mondange, Stella
[1
,2
]
Doumenq, Pierre
[1
]
Gonzalez, Catherine
[2
]
Malleret, Laure
[1
,2
]
机构:
[1] Aix Marseille Univ, Lab Chim Environm, CNRS, Marseille, France
[2] IMT Mines Ales, Lab Genie Environm Ind, 6 Ave Clavieres, F-30319 Ales, France
来源:
关键词:
Chlorinated paraffins;
European water framework directive;
Chemcatcher (R);
Silicone rubber;
Passive sampling;
Complex mixtures;
HYDROPHOBIC ORGANIC-CHEMICALS;
SOLID-PHASE MICROEXTRACTION;
AQUATIC ENVIRONMENTS PART;
LOW-DENSITY POLYETHYLENE;
DIFFUSION-COEFFICIENTS;
POLYETHERSULFONE PES;
GAS-CHROMATOGRAPHY;
POLLUTANTS;
CALIBRATION;
EXTRACTION;
D O I:
10.1016/j.talanta.2020.121920
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
Short-chain chlorinated paraffins (SCCPs) are high-volume chemicals raising concerns because of their classification as priority hazardous substances by the European Water Framework Directive (WFD) and their recent inclusion in the persistent organic pollutants' (POPs) list by the Stockholm convention. As this group cover up to 5000 isomers, their measurement is still challenging. Hence the SCCPs occurrence in the environment is poorly documented in comparison with other POPs, especially in matrices where they are present at ultratrace levels such as waters. In the two-past decades, passive sampling has been increasingly used as it overcomes some major drawbacks associated to the conventional grab sampling. This study constitutes the first work aiming to examine the passive sampling's applicability for the monitoring of such complex analytes' mixtures in waters. Optimization and calibration of two proven passive samplers, namely silicone rubbers and Chemcatcher (R), were performed through batch and laboratory pilot experiments. Despite the thousands of molecules present in the SCCPs mixture, the resulting global kinetic uptakes fitted well with the theorical model, for both samplers. Sampling rates of 8.0 L d(-1) for silicone rubbers and 0.53 L d(-1) for Chemcatcher (R) were found, and logKsw determined for silicone rubbers equaled 4.24 to 4.95. These values are in complete agreement with published data for other HOCs. A field trial carried out in marine coastal environments provided further evidence to demonstrate the applicability of the passive samplers to measure CPs amounts in water bodies. All these results unveil that passive sampling using silicone rubbers or Chemcatcher (R) can be a relevant approach to track traces of such complex mixtures in water.
引用
收藏
页数:11
相关论文