Portable and quantitative point-of-care monitoring of Escherichia coli O157:H7 using a personal glucose meter based on immunochromatographic assay

被引:82
作者
Huang, Haoran [1 ]
Zhao, Guangying [1 ]
Dou, Wenchao [1 ]
机构
[1] Zhejiang Gongshang Univ, Sch Food Sci & Biotechnol, Food Safety Key Lab Zhejiang Prov, Hangzhou 310018, Zhejiang, Peoples R China
关键词
Magnetic nanoparticles; Invertase; Personal glucose meter; Immunochromatographic assay; Pathogens detection; Escherichia coli O157:H7; SAMPLES;
D O I
10.1016/j.bios.2018.02.027
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Here we innovate a portable and quantitative immunochromatographic assay (ICA) with a personal glucose meter (PGM) as readout for the detection of Escherichia coli O157:H7 (E. coil O157:H7). The carboxyl group coated Fe3O4 nanoparticles (MNPs) were synthesized by a one pot method and used as carriers of invertase and monoclonal antibody against E. coli O157:H7. Initially, the invertase and antibody double functionalized MNPs (Invertase-MNPs-IgG) conjugates were prepared and used as label probe in this assay system. Before laminating onto the baking card, the absorbent pad was soaked in sucrose solution and desiccated. MNPs produced brown band at the detection zone of the ICA when acting as direct labels. As they were also coupled with invertase, the invertase catalyzed the hydrolysis of sucrose on the absorbent pad into glucose, which was detected by the PGM. To increase the sensitivity, antibody functionalized MNPs were used to enrich E. coli O157:H7 from sample solution. The innovative aspect of this approach lies in the visualization and quantification of E. coli O157:H7 through Invertase-MNPs-IgG and the detection of glucose concentration using PGM. Although the feasibility is demonstrated using E. coli O157:H7 as a model analyte, this approach can be easily developed to be a universal analysis system and applied to detection of a wide variety of foodbome pathogens and protein biomarkers. This study proposed a qualitative and quantitative analysis device for the clinic diagnostics and food safety analysis.
引用
收藏
页码:266 / 271
页数:6
相关论文
共 21 条
[1]   Detection of E. coli O157:H7 and Shigella dysenteriae toxins in clinical samples by PCR-ELISA [J].
Amani, Jafar ;
Ahmadpour, Askary ;
Fooladi, Abbas Ali Imani ;
Nazarian, Shahram .
BRAZILIAN JOURNAL OF INFECTIOUS DISEASES, 2015, 19 (03) :278-284
[2]   Detection of pathogenic Campylobacter, E-coli O157:H7 and Salmonella spp. in wastewater by PCR assay [J].
Bonetta, Si. ;
Pignata, C. ;
Lorenzi, E. ;
De Ceglia, M. ;
Meucci, L. ;
Bonetta, Sa. ;
Gilli, G. ;
Carraro, E. .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2016, 23 (15) :15302-15309
[3]   A portable and antibody-free sandwich assay for determination of chloramphenicol in food based on a personal glucose meter [J].
Chen, Si ;
Gan, Ning ;
Zhang, Huairong ;
Hu, Futao ;
Li, Tianhua ;
Cui, Huan ;
Cao, Yuting ;
Jiang, Qianli .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (09) :2499-2507
[4]   A bare-eye based one-step signal amplified semiquantitative immunochromatographic assay for the detection of imidacloprid in Chinese cabbage samples [J].
Fang, Qingkui ;
Wang, Limin ;
Cheng, Qi ;
Cai, Jia ;
Wang, Yulong ;
Yang, Mingming ;
Hua, Xiude ;
Liu, Fengquan .
ANALYTICA CHIMICA ACTA, 2015, 881 :82-89
[5]   Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol [J].
Gao, Hongfei ;
Han, Jing ;
Yang, Shijia ;
Wang, Zhenxing ;
Wang, Lin ;
Fu, Zhifeng .
ANALYTICA CHIMICA ACTA, 2014, 839 :91-96
[6]   A timer-actuated immunoassay cassette for detecting molecular markers in oral fluids [J].
Liu, Changchun ;
Qiu, Xianbo ;
Ongagna, Serge ;
Chen, Dafeng ;
Chen, Zongyuan ;
Abrams, William R. ;
Malamud, Daniel ;
Corstjens, Paul L. A. M. ;
Bau, Haim H. .
LAB ON A CHIP, 2009, 9 (06) :768-776
[7]   Highly Water-Dispersible Biocompatible Magnetite Particles with Low Cytotoxicity Stabilized by Citrate Groups [J].
Liu, Jia ;
Sun, Zhenkun ;
Deng, Yonghui ;
Zou, Ying ;
Li, Chunyuan ;
Guo, Xiaohui ;
Xiong, Liqin ;
Gao, Yuan ;
Li, Fuyou ;
Zhao, Dongyuan .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2009, 48 (32) :5875-5879
[8]   Comparison of 4 label-based immunochromatographic assays for the detection of Escherichia coli O157:H7 in milk [J].
Luo, Kai ;
Hu, Liming ;
Guo, Qi ;
Wu, Chenghui ;
Wu, Songsong ;
Liu, Daofeng ;
Xiong, Yonghua ;
Lai, Weihua .
JOURNAL OF DAIRY SCIENCE, 2017, 100 (07) :5176-5187
[9]   Food-related illness and death in the United States [J].
Mead, PS ;
Slutsker, L ;
Dietz, V ;
McCaig, LF ;
Bresee, JS ;
Shapiro, C ;
Griffin, PM ;
Tauxe, RV .
EMERGING INFECTIOUS DISEASES, 1999, 5 (05) :607-625
[10]   Immunochromatographic Assay of Hepatitis B Surface Antigen Using Magnetic Nanoparticles as Signal Materials [J].
Oh, Kyuha ;
Choi, Young Soo ;
Yoon, Ha Young ;
Park, Nami ;
Kim, Jooho ;
Kim, Young Keun .
IEEE TRANSACTIONS ON MAGNETICS, 2014, 50 (11)