Performance analysis of CCHP and CHP systems operating following the thermal and electric load

被引:216
作者
Mago, P. J. [1 ]
Fumo, N. [1 ]
Chamra, L. M. [1 ]
机构
[1] Mississippi State Univ, Dept Mech Engn, Mississippi State, MS 39762 USA
关键词
CHP systems; CCHP systems; operation modes; primary energy consumption; EXERGOECONOMIC ANALYSIS; ENERGY; OPTIMIZATION; DRIVEN; POWER; HEAT; COST;
D O I
10.1002/er.1526
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Heating and cooling energy requirements for buildings are usually supplied by separated systems such as furnaces or boilers for heating, and vapor compression systems for cooling. For these types of buildings, the use of combined cooling, heating, and power (CCHP) systems or combined heating and power (CHP) systems are an alternative for energy savings. Different researchers have claimed that the use of CCHP and CHP systems reduces the energy consumption related to transmission and distribution of energy. However, most of these analyses are based on reduction of operating cost without measuring the actual energy use and emissions reduction. The objective of this study is to analyze the performance of CCHP and CHP systems operating following the electric load (FEL) and operating following the thermal load (FTL), based on primary energy consumption (PEC), operation cost, and carbon dioxide emissions (CDE) for different climate conditions. Results show that CCHP and CHP systems operated FTL reduce the PEC for all the evaluated cities. On the other hand, CHP systems operated FEL always increases the PEC. The only operation mode that reduces PEC and CDE while reducing the cost is CHP-FTL. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:852 / 864
页数:13
相关论文
共 29 条
[1]  
*ACT, 2004, GPG388 ACT
[2]   Exergoeconomic analysis of a combined heat and power (CHP) system [J].
Balli, Ozgur ;
Aras, Haydar ;
Hepbasli, Arif .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (04) :273-289
[3]   Exergetic performance evaluation of a combined heat and power (CHP) system in Turkey [J].
Balli, Ozgur ;
Aras, Haydar ;
Hepbasli, Arif .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2007, 31 (09) :849-866
[4]  
Bruno JC, 2000, INT J ENERG RES, V24, P695, DOI 10.1002/1099-114X(20000625)24:8<695::AID-ER619>3.0.CO
[5]  
2-H
[6]   A new approach to exergoeconomic analysis and design of variable demand energy systems [J].
Cardona, E ;
Piacentino, A .
ENERGY, 2006, 31 (04) :490-515
[7]   A methodology for sizing a trigeneration plant in mediterranean areas [J].
Cardona, E ;
Piacentino, A .
APPLIED THERMAL ENGINEERING, 2003, 23 (13) :1665-1680
[8]  
*ENERGYPLUS, 2008, EN SIM SOFTW
[9]   System study of combined cooling, heating and power system for eco-industrial parks [J].
Gao, Lin ;
Wu, Hui ;
Jin, Hongguang ;
Yang, Minlin .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (12) :1107-1118
[10]  
Jalalzadeh-Azar A.A., 2004, ASHRAE T, P85