Ferrocenedicarboxylic Acid Modified Carbon Paste Electrode: A Sensor for Electrocatalytic Determination of Hydrochlorothiazide

被引:75
作者
Karimi-Maleh, H. [1 ]
Ensafi, Ali A. [1 ]
Ensafi, Hamid R. [2 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
[2] Payame Nour Univ, Dept Chem, Estahban, Iran
关键词
ferrocenedicarboxylic acid; hydrochlorothiazide; electrocatalysis; square wave voltammetry; ASCORBIC-ACID; HUMAN PLASMA; CHROMATOGRAPHY; OXIDATION; QUANTIFICATION; RESOLUTION; AMILORIDE; LOSARTAN; MIXTURE;
D O I
10.1590/S0103-50532009000500012
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The electrocatalytic oxidation of hydrochlorothiazide has been studied by ferrocenedicarboxylic acid modified carbon paste electrode. Cyclic voltammetry and chronoamperometry were used to investigate the suitability of ferrocenedicarboxylic acid as a mediator for the electrocatalytic oxidation of hydrochlorothiazide in aqueous solution. The oxidation of hydrochlorothiazide occurs at a potential about 300 mV less positive than with the unmodified carbon paste electrode at pH 9.0. The catalytic reaction rate constant, k(h) was calculated (3.38 x 10(2) cm(3) mol(-1) s(-1)) using chronoamperometry. Under the optimized conditions, the electrocatalytic oxidation peak current of hydrochlorothiazide showed two linear dynamic ranges with a detection limit of 0.037 mu mol L-1 hydrochlorothiazide. The linear calibration ranges were between 0.08-5.8 mu mol L-1 and 5.8-500.0 mu mol L-1 hydrochlorothiazide using square wave voltammetric method. Finally, the proposed method was also examined as a selective, simple and precise electrochemical sensor for the determination of hydrochlorothiazide in real samples such as drug and urine.
引用
收藏
页码:880 / 887
页数:8
相关论文
共 32 条
[21]   Sensitive liquid chromatography-tandem mass spectrometry method for quantification of hydrochlorothiazide in human plasma [J].
Ramakrishna, NVS ;
Vishwottam, KN ;
Manoj, S ;
Koteshwara, M ;
Wishu, S ;
Varma, DP .
BIOMEDICAL CHROMATOGRAPHY, 2005, 19 (10) :751-760
[22]  
Raoof JB, 2008, ASIAN J CHEM, V20, P483
[23]   Carbon paste electrode incorporating 1-[4-(ferrocenyl ethynyl) phenyl]-1-ethanone for electrocatalytic and voltammetric determination of tryptophan [J].
Raoof, Jahan-Bakhsh ;
Ojani, Reza ;
Karimi-Maleh, Hassan .
ELECTROANALYSIS, 2008, 20 (11) :1259-1262
[24]  
Raoof JB, 2007, INT J ELECTROCHEM SC, V2, P848
[25]   L-cysteine voltammetry at a carbon paste electrode bulk-modified with ferrocenedicarboxylic acid [J].
Raoof, Jahan-Bakhsh ;
Ojani, Reza ;
Beitollahi, Hadi .
ELECTROANALYSIS, 2007, 19 (17) :1822-1830
[26]   Electrochemical study of hydrochlorothiazide and its determination in urine and tablets [J].
Razak, OA .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (02) :433-440
[27]   METALLOPORPHYRIN CONTAINING CARBON PASTE ELECTRODES [J].
TAKEUCHI, ES ;
MURRAY, RW .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 188 (1-2) :49-57
[28]   Sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry analysis of hydrochlorothiazide in rat plasma [J].
Takubo, T ;
Okada, H ;
Ishii, M ;
Hara, K ;
Ishii, Y .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 806 (02) :199-203
[29]   PLS and first derivative of ratio spectra methods for determination of hydrochlorothiazide and propranolol hydrochloride in tablets [J].
Vignaduzzo, Silvana E. ;
Maggio, Ruben M. ;
Castellano, Patricia M. ;
Kaufman, Teodoro S. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (7-8) :2239-2244
[30]   Hydrochlorothiazide efficacy and polymorphisms in ACE, ADD1 and GNB3 in healthy, male volunteers [J].
Vormfelde, SV ;
Sehrt, D ;
Bolte, D ;
Pahl, S ;
Tzvetkov, M ;
Brockmöller, J .
EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 2006, 62 (03) :195-201