Anodic stripping voltammetry for direct determination of heavy metals in bovine seminal plasma using thick film modified graphite electrodes

被引:9
作者
Skiba, Tatyana, V [1 ,2 ]
Gou, Hueyhuey [2 ]
机构
[1] Russian Acad Sci, Nikolaev Inst Inorgan Chem, Dept Analyt Chem, Siberian Branch, 3 Acad Lavrentiev Ave, Novosibirsk 630090, Russia
[2] Novosibirsk Natl Res State Univ, 2 Pirogova St, Novosibirsk 630090, Russia
关键词
Seminal plasma; Film graphite electrode; Heavy metals; Stripping voltammetry; SEMEN PARAMETERS; TRACE-ELEMENTS; ZINC; COPPER; CADMIUM; LEAD; MAGNESIUM; QUALITY; BLOOD; CALCIUM;
D O I
10.1016/j.microc.2019.03.091
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The thick-film modified graphite sensors (TMGE) as working electrodes are used for determination of heavy metals in bovine seminal plasma by anodic stripping voltammetry. The technique proposed is a very simple, express and no any sample preparation such as acid deproteinization or autoclave digestion is necessary. The sample of seminal plasma is just diluted with electrolyte solution in the analysis process. The aliquot of the sample is injected in the electrochemical cell and the analytical signal is measured. The analytical signal de-pendences on the accumulation potential, accumulation time and sweep rate have been studied. The standard addition method is used for calculating of heavy metal concentrations in the samples. The accuracy of the developed technique is proved by comparison with the results obtained by the independent method of ICP-AES (atomic emission spectrometry with inductively coupled plasma). The detection limits (3SD(blank)) are found to be 3.6 mu g.L(-1)for Pb and 40 mu g.L(-1 )for Cu in bovine seminal plasma (taking into account sample dilution). The relative standard deviation (RSD) obtained by the proposed technique do not exceed 13%.
引用
收藏
页码:818 / 823
页数:6
相关论文
共 50 条
[31]   Review-Ion Interference and Elimination in Electrochemical Detection of Heavy Metals Using Anodic Stripping Voltammetry [J].
Yang, Yixuan ;
Huang, Yilu ;
Luo, Huili ;
Zhao, Jia ;
Bi, Junping ;
Wu, Genyi .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2023, 170 (05)
[32]   Simultaneous determination of Cd(II) and Pb(II) by differential pulse anodic stripping voltammetry based on graphite nanofibers-Nafion composite modified bismuth film electrode [J].
Li, Dongyue ;
Jia, Jianbo ;
Wang, Jianguo .
TALANTA, 2010, 83 (02) :332-336
[33]   Effects of modified fly ash doped carbon paste electrodes and metal film electrodes on the determination of trace cadmium(ii) by anodic stripping voltammetry [J].
Hou, Jinying ;
Fan, Yuping ;
Ma, Xiaomin ;
Dong, Xianshu ;
Yao, Suling .
RSC ADVANCES, 2021, 11 (28) :17240-17248
[34]   Electrochemically Reduced Graphene Oxide Pencil-Graphite in situ Plated Bismuth-film Electrode for the Determination of Trace Metals by Anodic Stripping Voltammetry [J].
Pokpas, Keagan ;
Zbeda, Salma ;
Jahed, Nazeem ;
Mohamed, Nuralli ;
Baker, Priscilla G. ;
Iwuoha, Emmanuel I. .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (02) :736-759
[35]   Simultaneous Determination of Pb and Cd Traces in Water Samples by Anodic Stripping Voltammetry Using a Modified GC Electrode [J].
Stankovic, Dalibor ;
Manojlovic, Dragan ;
Roglic, Goran ;
Kostic-Rajacic, Sladjana ;
Andjelkovic, Ivan ;
Dojcinovic, Biljana ;
Mutic, Jelena .
ELECTROANALYSIS, 2011, 23 (08) :1928-1933
[36]   Simultaneous Determination of Indium and Thallium Ions by Anodic Stripping Voltammetry Using Antimony Film Electrode [J].
Zhang, Jialing ;
Shan, Yujuan ;
Ma, Jing ;
Xie, Li ;
Du, Xiaoyan .
SENSOR LETTERS, 2009, 7 (04) :605-608
[37]   Comparison of plain and indoline modified mercury film electrodes for determination of lead, cadmium and copper in urine samples by anodic stripping voltammetry [J].
Duran, Serap Titretir ;
Karagozler, A. Ersin .
POLYMER BULLETIN, 2019, 76 (05) :2411-2425
[38]   Comparison of plain and indoline modified mercury film electrodes for determination of lead, cadmium and copper in urine samples by anodic stripping voltammetry [J].
Serap Titretir Duran ;
A. Ersin Karagözler .
Polymer Bulletin, 2019, 76 :2411-2425
[39]   Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell [J].
Zhao, Guo ;
Tran, Thien-Toan ;
Modha, Sidharth ;
Sedki, Mohammed ;
Myung, Nosang V. ;
Jassby, David ;
Mulchandani, Ashok .
FRONTIERS IN CHEMISTRY, 2022, 10
[40]   An electrochemical sensor for the determination of Cu(II) using a modified electrode with ferrocenyl crown ether compound by square wave anodic stripping voltammetry [J].
Flores, Erick ;
Pizarro, Jaime ;
Godoy, Fernando ;
Segura, Rodrigo ;
Gomez, Alejandra ;
Agurto, Nicolas ;
Sepulveda, Pamela .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 251 :433-439