摘要
The thick-film modified graphite sensors (TMGE) as working electrodes are used for determination of heavy metals in bovine seminal plasma by anodic stripping voltammetry. The technique proposed is a very simple, express and no any sample preparation such as acid deproteinization or autoclave digestion is necessary. The sample of seminal plasma is just diluted with electrolyte solution in the analysis process. The aliquot of the sample is injected in the electrochemical cell and the analytical signal is measured. The analytical signal de-pendences on the accumulation potential, accumulation time and sweep rate have been studied. The standard addition method is used for calculating of heavy metal concentrations in the samples. The accuracy of the developed technique is proved by comparison with the results obtained by the independent method of ICP-AES (atomic emission spectrometry with inductively coupled plasma). The detection limits (3SD(blank)) are found to be 3.6 mu g.L(-1)for Pb and 40 mu g.L(-1 )for Cu in bovine seminal plasma (taking into account sample dilution). The relative standard deviation (RSD) obtained by the proposed technique do not exceed 13%.
引用
收藏
页码:818 / 823
页数:6
相关论文
共 50 条
[21]   Graphene Oxide-Modified Electrode Coated with in-situ Antimony Film for the Simultaneous Determination of Heavy Metals by Sequential Injection-Anodic Stripping Voltammetry [J].
Ruengpirasiri, Prasongporn ;
Punrat, Eakkasit ;
Chailapakul, Orawon ;
Chuanuwatanakul, Suchada .
ELECTROANALYSIS, 2017, 29 (04) :1022-1030
[22]   Advance in the Stripping Voltammetry Using Alloy Electrodes for the Determination of Heavy Metal Ions [J].
Zhang, Xuzhi ;
Qu, Keming ;
Li, Dongpeng .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (10) :8497-8512
[23]   A Nafion-coated bismuth film electrode for the determination of heavy metals in vegetable using differential pulse anodic stripping voltammetry: An alternative to mercury-based electrodes [J].
Xu, He ;
Zeng, Liping ;
Huang, Dekun ;
Man, Yuezhong ;
Jin, Litong .
FOOD CHEMISTRY, 2008, 109 (04) :834-839
[24]   3D-printed Metal Electrodes for Heavy Metals Detection by Anodic Stripping Voltammetry [J].
Lee, Ke Yau ;
Ambrosi, Adriano ;
Pumera, Martin .
ELECTROANALYSIS, 2017, 29 (11) :2444-2453
[25]   Determination of Trace Metals by Anodic Stripping Voltammetry Using a Carbon Nanotube Tower Electrode [J].
Guo, Xuefei ;
Yun, Yeoheung ;
Shanov, Vesselin N. ;
Halsall, H. Brian ;
Heineman, William R. .
ELECTROANALYSIS, 2011, 23 (05) :1252-1259
[26]   Determination of trace heavy metal ions by anodic stripping voltammetry using nanofibrillated cellulose modified electrode [J].
Zinoubi, K. ;
Majdoub, H. ;
Barhoumi, H. ;
Boufi, S. ;
Jaffrezic-Renault, N. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 799 :70-77
[27]   Nano-alumina coated with SDS and modified with salicylaldehyde-5-sulfonate for extraction of heavy metals and their determination by anodic stripping voltammetry [J].
Rajabi, Maryam ;
Mohammadi, Bahram ;
Asghari, Alireza ;
Barfi, Behruz ;
Behzad, Mandi .
JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2014, 20 (05) :3737-3743
[28]   Determination of the fungicide picoxystrobin using anodic stripping voltammetry on a metal film modified glassy carbon electrode [J].
Dornellas, Rafael M. ;
Franchini, Romulo A. A. ;
Aucelio, Ricardo Q. .
ELECTROCHIMICA ACTA, 2013, 97 :202-209
[29]   GRAPHITE ELECTRODES MODIFIED WITH GOLD-POLYMER COMPOUND FOR MERCURY DETERMINATION BY STRIPPING VOLTAMMETRY [J].
Vladimir, Shelkovnikov V. ;
Mikhail, Anishchenko V. ;
Anna, Shulga K. ;
Konstantin, Minaev M. .
TOMSK STATE UNIVERSITY JOURNAL, 2013, (368) :204-+
[30]   Detection of Cd2+ by Square Wave Anodic Stripping Voltammetry Using an Activated Bismuth-film Electrodes [J].
Yao Mei-Na ;
Yang Xian-Jin ;
Cui Zhen-Duo ;
Zhu Sheng-Li ;
Li Zhao-Yang ;
Liang Yan-Qin .
JOURNAL OF INORGANIC MATERIALS, 2019, 34 (01) :91-95