Testing the accuracy of the two-dimensional object model in HAADF STEM

被引:5
作者
Jones, Lewys [1 ]
Nellist, Peter D. [1 ]
机构
[1] Univ Oxford, Dept Mat, Oxford OX1 3PH, England
关键词
HAADF STEM; Depth resolution; Focal series; Object function; Point spread function; TRANSMISSION ELECTRON-MICROSCOPE; ADF-STEM; ABERRATION; RESOLUTION;
D O I
10.1016/j.micron.2013.12.012
中图分类号
TH742 [显微镜];
学科分类号
摘要
In high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) the two-dimensional (2D) object-function approximation and image convolution model is often used to describe the recorded image data from on-axis crystalline samples. In this model the sample, represented by an object function with sharp peaks at the atomic column positions, is convolved with the 2D point spread function (PSF) of the focussed STEM illumination. In this work the validity of the assumption that the object can be considered as 2D is evaluated experimentally through the use of HAADF-STEM focal-series from MgO smoke cubes. The intensity of laterally resolved image-information is evaluated using Fourier transforms and is tracked with respect to defocus. The experimental results are compared with the expected depth resolution capabilities of simulated STEM probes to yield the normalised or 'apparent thickness' of the samples. The 2D object-function and image convolution models are found to hold for sample thicknesses of up to 250 nm. As the 2D object model holds true for each individual frame in a recorded focal series, we can hence express the focal-series as a whole as the convolution of a 2D object function with a 3D probe function with implications for both the diagnosis of remnant aberrations and also image reconstruction. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:47 / 51
页数:5
相关论文
共 50 条
  • [1] A memory efficient method for fully three-dimensional object reconstruction with HAADF STEM
    Van den Broek, W.
    Rosenauer, A.
    Van Aert, S.
    Sijbers, J.
    Van Dyck, D.
    ULTRAMICROSCOPY, 2014, 141 : 22 - 31
  • [2] Composition determination of semiconductor alloys towards atomic accuracy by HAADF-STEM
    Duschek, L.
    Kukelhan, P.
    Beyer, A.
    Firoozabadi, S.
    Oelerich, J. O.
    Fuchs, C.
    Stolz, W.
    Ballabio, A.
    Isella, G.
    Volz, K.
    ULTRAMICROSCOPY, 2019, 200 : 84 - 96
  • [3] Evaluation of two-dimensional strain distribution by STEM/NBD
    Uesugi, Fumihiko
    Hokazono, Akira
    Takeno, Shiro
    ULTRAMICROSCOPY, 2011, 111 (08) : 995 - 998
  • [4] Apodization of two-dimensional pupils with aberrations
    Andra Naresh Kumar Reddy
    Mahdieh Hashemi
    Svetlana Nikolaevna Khonina
    Pramana, 2018, 90
  • [5] Apodization of two-dimensional pupils with aberrations
    Reddy, Andra Naresh Kumar
    Hashemi, Mahdieh
    Khonina, Svetlana Nikolaevna
    PRAMANA-JOURNAL OF PHYSICS, 2018, 90 (06):
  • [6] Focusing properties of two-dimensional photonic quasicrystal flat lens at different object distances
    Liu, Jianjun
    Zuo, Baojun
    Chen, Shouqian
    Hu, Haili
    Xiao, Haosu
    Zhang, Wang
    Fan, Zhigang
    Guo, Hao
    Zhang, Xiong
    OPTICAL ENGINEERING, 2012, 51 (07)
  • [7] A study of the precision and accuracy of peak quantification in comprehensive two-dimensional liquid chromatography in time
    Thekkudan, Dennis F.
    Rutan, Sarah C.
    Carr, Peter W.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (26) : 4313 - 4327
  • [8] Model-based deconvolution for particle analysis applied to a through-focus series of HAADF-STEM images
    Ohsuna, Tetsu
    Oh-ishi, Keiichiro
    MICROSCOPY, 2023, 72 (04) : 368 - 380
  • [9] Numerical investigation of a mixture two-phase flow model in two-dimensional space
    Zeidan, D.
    Baehr, P.
    Farber, P.
    Graebel, J.
    Ueberholz, P.
    COMPUTERS & FLUIDS, 2019, 181 (90-106) : 90 - 106
  • [10] Two-dimensional plasmonic metamaterials
    I.I. Smolyaninov
    Applied Physics A, 2007, 87 : 227 - 234