Simplifying Nucleic Acid Amplification from Whole Blood with Direct Polymerase Chain Reaction on Chitosan Microparticles

被引:27
作者
Nanayakkara, Imaly A. [1 ]
Cao, Weidong [2 ]
White, Ian M. [1 ]
机构
[1] Univ Maryland, Fischell Dept Bioengn, College Pk, MD 20742 USA
[2] Canon US Life Sci Inc, Rockville, MD 20850 USA
关键词
A-CHIP SYSTEM; SAMPLE PREPARATION; DEVICE; DNA; ASSAY; PCR; PURIFICATION; EXTRACTION;
D O I
10.1021/acs.analchem.7b00274
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tremendous advances have been made in the development of portable nucleic acid amplification devices for near-patient use. However, the true limitation in the realization of nucleic acid amplification tests (NAATs) for hear-patient applications is not the amplification reaction, it is the complexity of the sample preparation. Conventional approaches require several precise intervention steps during the protocol. There are numerous reports in the literature that mimic the sample preparation procedure within a lab-on-a-chip device or cartridge, but these systems require a high number of integrated steps, making the devices and/or their supporting equipment too complex to meet the necessary cost targets and regulatory requirements for near-patient applications. Here we report a simplified method to purify and amplify DNA from complex samples in a minimal number of steps. We show that chitosan-coated microparticles can lyse human cells and capture the released DNA in a single mechanical agitation step, and we show that bound DNA can be amplified directly from the microparticle surface when the magnetic microparticles are transferred to a polymerase chain reaction (PCR). This procedure eliminates (i) the use of PCR-inhibiting reagents (e.g., chaotropic salts and alcohol) and (ii) the washing and elution steps that are required to remove these reagents and release DNA in typical NAAT sample preparation methods. To illustrate the use of this direct PCR method in diagnostics, we amplify human genomic DNA sequences from a similar to 1 mu L, droplet of whole blood, and we amplify plasmid DNA spiked into whole blood droplets to represent circulating viral DNA or cell-free DNA. The qPCR threshold cycle for direct PCR from whole blood is comparable to that of direct PCR with purified DNA, demonstrating that the lysis and capture steps effectively bind DNA and sufficiently enable its amplification. Furthermore, the efficient amplification of plasmid DNA spiked into,whole blood proves that the large mass of human genomic DNA captured from the lysed cells does hot inhibit the capture and amplification of other circulating DNA. We anticipate that this new streamlined method for preparing DNA for amplification will expand the diagnostic applications of nucleic acid amplification tests, in particular for near-patient applications.
引用
收藏
页码:3773 / 3779
页数:7
相关论文
共 33 条
  • [1] Handheld real-time PCR device
    Ahrberg, Christian D.
    Ilic, Bojan Robert
    Manz, Andreas
    Neuzil, Pavel
    [J]. LAB ON A CHIP, 2016, 16 (03) : 586 - 592
  • [2] Miniaturized isothermal nucleic acid amplification, a review
    Asiello, Peter J.
    Baeumner, Antje J.
    [J]. LAB ON A CHIP, 2011, 11 (08) : 1420 - 1430
  • [3] Miniaturised nucleic acid analysis
    Auroux, PA
    Koc, Y
    deMello, A
    Manz, A
    Day, PJR
    [J]. LAB ON A CHIP, 2004, 4 (06) : 534 - 546
  • [4] RAPID AND SIMPLE METHOD FOR PURIFICATION OF NUCLEIC-ACIDS
    BOOM, R
    SOL, CJA
    SALIMANS, MMM
    JANSEN, CL
    WERTHEIMVANDILLEN, PME
    VANDERNOORDAA, J
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (03) : 495 - 503
  • [5] Acid-base equilibria of weak polyelectrolytes in multilayer thin films
    Burke, SE
    Barrett, CJ
    [J]. LANGMUIR, 2003, 19 (08) : 3297 - 3303
  • [6] Chitosan as a polymer for pH-induced DNA capture in a totally aqueous system
    Cao, Weidong
    Easley, Christopher J.
    Ferrance, Jerome P.
    Landers, James P.
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (20) : 7222 - 7228
  • [7] PERFORMANCE OF THE COBAS (R) INFLUENZA A/B ASSAY FOR RAPID PCR-BASED DETECTION OF INFLUENZA COMPARED TO PRODESSE ProFlu+ AND VIRAL CULTURE
    Chen, L.
    Tian, Y.
    Chen, S.
    Liesenfeld, O.
    [J]. EUROPEAN JOURNAL OF MICROBIOLOGY AND IMMUNOLOGY, 2015, 5 (04): : 236 - 245
  • [8] The microfluidic chip module for the detection of murine norovirus in oysters using charge switchable micro-bead beating
    Chung, Sung Hee
    Baek, Changyoon
    Cong, Vu Tan
    Min, Junhong
    [J]. BIOSENSORS & BIOELECTRONICS, 2015, 67 : 625 - 633
  • [9] Integrated microfluidic tmRNA purification and real-time NASBA device for molecular diagnostics
    Dimov, Ivan K.
    Garcia-Cordero, Jose L.
    O'Grady, Justin
    Poulsen, Claus R.
    Viguier, Caroline
    Kent, Lorcan
    Daly, Paul
    Lincoln, Bryan
    Maher, Majella
    O'Kennedy, Richard
    Smith, Terry J.
    Ricco, Antonio J.
    Lee, Luke P.
    [J]. LAB ON A CHIP, 2008, 8 (12) : 2071 - 2078
  • [10] A fully integrated microfluidic genetic analysis system with sample-in-answer-out capability
    Easley, Christopher J.
    Karlinsey, James M.
    Bienvenue, Joan M.
    Legendre, Lindsay A.
    Roper, Michael G.
    Feldman, Sanford H.
    Hughes, Molly A.
    Hewlett, Erik L.
    Merkel, Tod J.
    Ferrance, Jerome P.
    Landers, James P.
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (51) : 19272 - 19277