Pulse wave transit time for monitoring respiration rate

被引:32
作者
Johansson, A. [1 ]
Ahlstrom, C.
Lanne, T.
Ask, P.
机构
[1] Linkoping Univ, Dept Biomed Engn, S-58183 Linkoping, Sweden
[2] Univ Hosp Orebro, Orebro, Sweden
[3] Linkoping Univ, Dept Med & Care, S-58183 Linkoping, Sweden
关键词
pulse wave transit time; respiration rate; respiration monitoring; blood pressure; photoplethysmography;
D O I
10.1007/s11517-006-0064-y
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this study, we investigate the beat-to-beat respiratory fluctuations in pulse wave transit time (PTT) and its subcomponents, the cardiac pre-ejection period (PEP) and the vessel transit time (VTT) in ten healthy subjects. The three transit times were found to fluctuate in pace with respiration. When applying a simple breath detecting algorithm, 88% of the breaths seen in a respiration air-flow reference could be detected correctly in PTT. Corresponding numbers for PEP and VTT were 76 and 81%, respectively. The performance during hypo- and hypertension was investigated by invoking blood pressure changes. In these situations, the error rates in breath detection were significantly higher. PTT can be derived from signals already present in most standard monitoring set-ups. The transit time technology thus has prospects to become an interesting alternative for respiration rate monitoring.
引用
收藏
页码:471 / 478
页数:8
相关论文
共 25 条
[1]  
AHLSTROM C, 2004, P 26 ANN INT C IEEE
[2]   Noninvasive investigation of blood pressure changes using the pulse wave transit time: A novel approach in the monitoring of hemodialysis patients [J].
Ahlstrom C. ;
Johansson A. ;
Uhlin F. ;
Länne T. ;
Ask P. .
Journal of Artificial Organs, 2005, 8 (3) :192-197
[3]   Differentiating obstructive and central sleep respiratory events through pulse transit time [J].
Argod, J ;
Pépin, JL ;
Lévy, P .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (06) :1778-1783
[4]   Comparison of esophageal pressure with pulse transit time as a measure of respiratory effort for scoring obstructive nonapneic respiratory events [J].
Argod, J ;
Pépin, JL ;
Smith, RP ;
Lévy, P .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 162 (01) :87-93
[5]   Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration [J].
Chen, W ;
Kobayashi, T ;
Ichikawa, S ;
Takeuchi, Y ;
Togawa, T .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (05) :569-574
[6]  
ELASIR B, 1996, P 1996 IEEE TENCON C, V2, P553
[7]  
FRANCHI D, 1996, COMPUT CARDIOL, V9, P397
[8]   CHANGES IN TIDAL VOLUME, FREQUENCY, AND VENTILATION INDUCED BY THIR MEASUREMENT [J].
GILBERT, R ;
AUCHINCL.JH ;
BODEN, W ;
BRODSKY, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1972, 33 (02) :252-&
[9]   Neural network for photoplethysmographic respiratory rate monitoring [J].
Johansson, A .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2003, 41 (03) :242-248
[10]  
JOHANSSON A, 2004, SENSORS APPL SENSORS