Detection and size measurements of pulmonary nodules in ultra-low-dose CT with iterative reconstruction compared to low dose

被引:51
作者
Sui, Xin [1 ]
Meinel, Felix G. [2 ,3 ]
Song, Wei [1 ]
Xu, Xiaoli [1 ]
Wang, Zixing [4 ,5 ]
Wang, Yuyan [4 ,5 ]
Jin, Zhengyu [1 ]
Chen, Jiuhong [6 ]
Vliegenthart, Rozemarijn [2 ,7 ]
Schoepf, U. Joseph [2 ]
机构
[1] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Radiol, Beijing 100730, Peoples R China
[2] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
[3] Univ Munich, Dept Clin Radiol, Munich, Germany
[4] Chinese Acad Med Sci, Inst Basic Med Sci, Dept Epidemiol & Biostat, Beijing 100730, Peoples R China
[5] Peking Union Med Coll, Sch Basic Med, Beijing, Peoples R China
[6] Siemens China, Beijing, Peoples R China
[7] Univ Groningen, Univ Med Ctr Groningen, Ctr Med Imaging North East Netherlands, Dept Radiol, Groningen, Netherlands
关键词
Imaging; Three-Dimensional; Solitary Pulmonary Nodule; Computed Tomography; radiation dosage; LUNG-CANCER; CHEST; OBSERVER; TOMOSYNTHESIS; RADIOGRAPHY; VOLUMETRY; TIME;
D O I
10.1016/j.ejrad.2015.12.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: In this study, the accuracy of ultra-low-dose computed tomography (CT) with iterative reconstruction (IR) for detection and measurement of pulmonary nodules was evaluated. Methods: Eighty-four individuals referred for lung cancer screening (mean age: 54.5 +/- 10.8 years) underwent low-dose computed tomography (LDCT) and ultra-low-dose CT. CT examinations were performed with attenuation-based tube current modulation. Reference tube voltage and current were set to 120 kV/25 mAs for LDCT and 80 kV/4 mAs for ultra-low-dose CT. CT images were reconstructed with filtered back projection (FBP) for LDCT, and with FBP and IR for ultra-low-dose CT datasets. A reference standard was established by a consensus panel of 2 different radiologists on LDCT. Volume and diameter of the solid nodules were measured on LDCT with FBP and ultra-low dose CT with FBP and IR. Interobserver and interscan variability were analyzed and compared by the Bland-Altman method. Results: A total of 127 nodules were identified, including 105 solid nodules, 15 part solid nodules, 7 ground glass nodules. On ultra-low-dose CT scans, the effective radiation dose was 0.13 +/- 0.11 mSv. A total of 113 (88.9%) and 110 (86.6%) true-positive nodules with FBP versus 117 (92.1%) and 118(92.9%) with IR were detected by two observers, respectively. The volume and size of the 105 solid nodules were measured, with mean volume/diameter of 46.5 +/- 46.6 mm(3) /5.1 +/- 1.6 mm. There was no significant difference in nodule volume or diameter measurements between ultra-low-dose CT and LDCT protocols for solid nodules. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:564 / 570
页数:7
相关论文
共 50 条
  • [41] Multiple Adversarial Learning Based Angiography Reconstruction for Ultra-Low-Dose Contrast Medium CT
    Zhang, Weiwei
    Zhou, Zhen
    Gao, Zhifan
    Yang, Guang
    Xu, Lei
    Wu, Weiwen
    Zhang, Heye
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2023, 27 (01) : 409 - 420
  • [42] Application of deep learning reconstruction of ultra-low-dose abdominal CT in the diagnosis of renal calculi
    Zhang, Xiaoxiao
    Zhang, Gumuyang
    Xu, Lili
    Bai, Xin
    Zhang, Jiahui
    Xu, Min
    Yan, Jing
    Zhang, Daming
    Jin, Zhengyu
    Sun, Hao
    [J]. INSIGHTS INTO IMAGING, 2022, 13 (01)
  • [43] Persistent pulmonary subsolid nodules: model-based iterative reconstruction for nodule classification and measurement variability on low-dose CT
    Kim, Hyungjin
    Park, Chang Min
    Kim, Seong Ho
    Lee, Sang Min
    Park, Sang Joon
    Lee, Kyung Hee
    Goo, Jin Mo
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (11) : 2700 - 2708
  • [44] Comparison of computer-aided detection (CADe) capability for pulmonary nodules among standard-, reduced- and ultra-low-dose CTs with and without hybrid type iterative reconstruction technique
    Ohno, Yoshiharu
    Aoyagi, Kota
    Chen, Qi
    Sugihara, Naoki
    Iwasawa, Tae
    Okada, Fumito
    Aoki, Takatoshi
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2018, 100 : 49 - 57
  • [45] The use of ultra-low-dose CT scans for the evaluation of limb fractures
    Konda, S. R.
    Goch, A. M.
    Leucht, P.
    Christiano, A.
    Gyftopoulos, S.
    Yoeli, G.
    Egol, K. A.
    [J]. BONE & JOINT JOURNAL, 2016, 98B (12) : 1668 - 1673
  • [46] Combination of Deep Learning-Based Denoising and Iterative Reconstruction for Ultra-Low-Dose CT of the Chest: Image Quality and Lung-RADS Evaluation
    Hata, Akinori
    Yanagawa, Masahiro
    Yoshida, Yuriko
    Miyata, Tomo
    Tsubamoto, Mitsuko
    Honda, Osamu
    Tomiyama, Noriyuki
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (06) : 1321 - 1328
  • [47] Detectability of Lung Nodules in Ultra-low Dose CT
    Janssen, Sonja
    Overhoff, Daniel
    Froelich, Matthias F.
    Schoenberg, Stefan O.
    Rathmann, Nils
    [J]. ANTICANCER RESEARCH, 2021, 41 (10) : 5053 - 5058
  • [48] Detection of pulmonary nodules: a clinical study protocol to compare ultra-low dose chest CT and standard low-dose CT using ASIR-V
    Ludwig, Marie
    Chipon, Emilie
    Cohen, Julien
    Reymond, Emilie
    Medici, Maud
    Cole, Anthony
    Moreau Gaudry, Alexandre
    Ferretti, Gilbert
    [J]. BMJ OPEN, 2019, 9 (08):
  • [49] Evaluation of an iterative model-based CT reconstruction algorithm by intra-patient comparison of standard and ultra-low-dose examinations
    Noel, Peter B.
    Engels, Stephan
    Koehler, Thomas
    Muenzel, Daniela
    Franz, Daniela
    Rasper, Michael
    Rummeny, Ernst J.
    Dobritz, Martin
    Fingerle, Alexander A.
    [J]. ACTA RADIOLOGICA, 2018, 59 (10) : 1225 - 1231
  • [50] Ultra-low-dose CT Imaging of the Thorax: Decreasing the Radiation Dose by One Order of Magnitude
    Lambert, Lukas
    Banerjee, Rohan
    Votruba, Jiri
    El-Lababidi, Nabil
    Zeman, Jiri
    [J]. INDIAN JOURNAL OF PEDIATRICS, 2016, 83 (12-13) : 1479 - 1481