Compressive behavior of CFRP-confined post heated square CFST stub columns

被引:29
作者
Chen, Yu [1 ,2 ]
Wang, Kai [2 ]
He, Kang [1 ]
Wei, Jiangang [1 ]
Wan, Jun [2 ]
机构
[1] Fuzhou Univ, Coll Civil Engn, Fuzhou 350116, Fujian, Peoples R China
[2] Yangtze Univ, Sch Urban Construct, Jingzhou 434023, Peoples R China
基金
中国国家自然科学基金;
关键词
Concrete-filled steel tube (CFST); Stub columns; Post heated; CFRP sheets; Ultimate strength; Design formulae; STEEL TUBE COLUMNS; REHABILITATION; BEAM;
D O I
10.1016/j.tws.2018.02.012
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The axial compressive behavior of carbon fiber reinforced polymer (CFRP)-confined post heated square concrete filled steel tube (CFST) stub columns is experimentally investigated in this paper. Twenty CFRP-confined post heated square CFST stub columns and one CFST stub column left untreated at ambient temperature were axially tested. Subsequently, the failure mode, ultimate strength, load versus displacement curves, load versus strain distribution curves, initial stiffness, and ductility of the specimens were obtained and analyzed. The maximum temperature (600 degrees C, 800 degrees C,1000 degrees C, 1100 degrees C) CFST stub columns exposed to and the number of the layer of CFRP sheets (zero, one, two, three and four) were considered as main parameters. The test results showed that, in general, the CFST stub columns wrapped with CFRP sheets shown a better mechanical behavior than those without CFRP sheets wrapping. Furthermore, the more the layers of CFRP sheets are, the higher the ultimate strength and initial stiffness of the CFST stub columns are. Based on the regression of the test data, the simplified formulae for ultimate strength of CFRP-confined post heated square CFST stub columns was proposed. Accuracy of the formulae was evaluated by comparison between the calculated and experimental results.
引用
收藏
页码:434 / 445
页数:12
相关论文
共 34 条
[11]  
Chinese Standard, 2008, 997882008 GBT CHIN S
[12]   Structural behaviour of recycled aggregate concrete filled steel tube columns strengthened by CFRP [J].
Dong, J. F. ;
Wang, Q. Y. ;
Guan, Z. W. .
ENGINEERING STRUCTURES, 2013, 48 :532-542
[13]   CFRP strengthening and rehabilitation of corroded steel pipelines under direct indentation [J].
Elchalakani, Mohamed ;
Karrech, Ali ;
Basarir, Hakan ;
Hassanein, M. F. ;
Fawzia, Sabrina .
THIN-WALLED STRUCTURES, 2017, 119 :510-521
[14]   Strengthening of mild steel struts using CFRP sheets subjected to uniform axial compression [J].
Elchalakani, Mohamed ;
Karrech, Ali ;
Basarir, Hakan ;
Zhao, Xiao-Ling ;
Fawzia, Sabrina ;
Hassanein, M. F. .
THIN-WALLED STRUCTURES, 2017, 116 :96-112
[15]   Rehabilitation of corroded steel CHS under combined bending and bearing using CFRP [J].
Elchalakani, Mohamed .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 125 :26-42
[16]   CFRP strengthening and rehabilitation of degraded steel welded RHS beams under combined bending and bearing [J].
Elchalakani, Mohamed .
THIN-WALLED STRUCTURES, 2014, 77 :86-108
[17]   Concrete-filled hollow structural steel columns after exposure to ISO-834 fire standard [J].
Han, LH ;
Huo, JS .
JOURNAL OF STRUCTURAL ENGINEERING, 2003, 129 (01) :68-78
[18]   Analytical behaviour of RC beam to CFST column frames subjected to fire [J].
Han, Lin-Hai ;
Wang, Wei-Hua ;
Yu, Hong-Xia .
ENGINEERING STRUCTURES, 2012, 36 :394-410
[19]  
ISO, 1975, International Standard ISO 834
[20]   Effectiveness of cement and plaster layers in protection of FRP confined concrete exposed to high temperatures [J].
Mostefa, Adda Hadj ;
Ghernouti, Youcef ;
Sebaibi, Yahia .
JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2015, 29 (09) :839-860