Comparison between optical coherence tomography and intravascular ultrasound in detecting neointimal healing patterns after stent implantation

被引:4
作者
Kochman, Janusz [1 ]
Pietrasik, Arkadiusz [1 ]
Rdzanak, Adam [1 ]
Jakala, Jacek [2 ]
Zasada, Wojciech [2 ]
Scibisz, Anna [1 ]
Koltowski, Lukasz [1 ]
Proniewska, Klaudia [2 ]
Pociask, Elzbieta [2 ]
Legutko, Jacek [3 ]
机构
[1] Med Univ Warsaw, Dept Cardiol 1, PL-02091 Warsaw, Poland
[2] Krakow Cardiovasc Res Inst, Krakow, Poland
[3] Jagiellonian Univ, Dept Intervent Cardiol, Krakow, Poland
关键词
angiography; IVUS; OCT; in-stent restenosis; neointima; CORONARY-ARTERIES; CLINICAL-APPLICATIONS; BARE-METAL; COVERAGE; DOCUMENT; VIVO; TERMINOLOGY; ACQUISITION; METHODOLOGY;
D O I
10.5603/KP.a2013.0317
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The amount of data comparing intravascular ultrasound (IVUS) and optical coherence tomography (OCT) for the detection of stent coverage in clinical settings is limited. Aim: To make a qualitative and quantitative assessment of the vascular healing patterns in patients after stent implantations visualised by both IVUS and OCT. Methods: Images were obtained in patients with clinical symptoms of angina, who had had a bare metal stent implanted in the previous 12 months. Angiography, IVUS and OCT were performed in 14 coronary arteries. Measurements of stent, lumen and neo-intima areas and dimensions were performed in stented regions and in both 10 mm references. IVUS, OCT, and angiographic data were compared in matched regions. Off-line analyses were performed by an independent core lab. Results: 14 stents were imaged without any procedural complications. The nominal stent length was 28 +/- 4.5 mm. OCT was the most accurate technique for assessing stent length (28.12 +/- 6.8 mm), while QCA underestimated length due to foreshortening (22.16 +/- 6.39 mm) and IVUS was vulnerable to random error due to discontinuous pullbacks and vessel movements (24.21 +/- 7.90 mm). Minimum lumen area (MLA) and minimum lumen diameter (MLD) in reference sites were comparable in IVUS and OCT, whereas there were significant differences between these two modalities for MLA (3.30 +/- 1.49 vs. 2.19 +/- 1.30 mm(2), p = 0.0046) and for MLD (2.42 +/- 0.51 vs. 1.58 +/- 0.56 mm(2), p = 0.0023) in stented segments. There was a slight overestimation of lumen volume (130.18 +/- 70.61 vs. 117.82 +/- 67.02 mm(3), p = 0.7256), a marked overestimation of stent volume (179.29 +/- 97.58 vs. 226.46 +/- 108.76 mm(3), p = 0.0544) and a statistically significant difference in the neointima volume (49.11 +/- 39.70 vs. 108.64 +/- 43.77 mm(3), p = 0.0060) by IVUS compared to OCT. Mean neointima burden in IVUS was much smaller than in OCT (20.79 +/- 14.27% vs. 58.16 +/- 18.25%, p = 0.0033). Conclusions: OCT can precisely quantify struts coverage and is more accurate than IVUS in the assessment of vascular healing in patients after stent implantation.
引用
收藏
页码:534 / 540
页数:7
相关论文
共 14 条
[1]   Comparison of optical coherence tomography and intravascular ultrasound for the assessment of in-stent tissue coverage after stent implantation [J].
Capodanno, Davide ;
Prati, Francesco ;
Pawlowsky, Tomasz ;
Cera, Maria ;
La Manna, Alessio ;
Albertucci, Mario ;
Tamburino, Corrado .
EUROINTERVENTION, 2009, 5 (05) :538-543
[2]   Quantitative Ex Vivo and In Vivo Comparison of Lumen Dimensions Measured by Optical Coherence Tomography and Intravascular Ultrasound in Human Coronary Arteries [J].
Gonzalo, Nieves ;
Serruys, Patrick W. ;
Garcia-Garcia, Hector M. ;
van Soest, Gijs ;
Okamura, Takayuki ;
Ligthart, Jurgen ;
Knaapen, Michiel ;
Verheye, Stefan ;
Bruining, Nico ;
Regar, Evelyn .
REVISTA ESPANOLA DE CARDIOLOGIA, 2009, 62 (06) :615-624
[3]   Strut Coverage and Vessel Wall Response to Zotarolimus-Eluting and Bare-Metal Stents Implanted in Patients With ST-Segment Elevation Myocardial Infarction The OCTAMI (Optical Coherence Tomography in Acute Myocardial Infarction) Study [J].
Guagliumi, Giulio ;
Sirbu, Vasile ;
Bezerra, Hiram ;
Biondi-Zoccai, Giuseppe ;
Fiocca, Luigi ;
Musumeci, Giuseppe ;
Matiashvili, Aleksandre ;
Lortkipanidze, Nikoloz ;
Tahara, Satoko ;
Valsecchi, Orazio ;
Costa, Marco .
JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (06) :680-687
[4]   Optical Coherence Tomography Assessment of In Vivo Vascular Response After Implantation of Overlapping Bare-Metal and Drug-Eluting Stents [J].
Guagliumi, Giulio ;
Musumeci, Giuseppe ;
Sirbu, Vasile ;
Bezerra, Hiram G. ;
Suzuki, Nobuaki ;
Fiocca, Luigi ;
Matiashvili, Aleksandre ;
Lortkipanidze, Nikoloz ;
Trivisonno, Antonio ;
Valsecchi, Orazio ;
Biondi-Zoccai, Giuseppe ;
Costa, Marco A. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (05) :531-539
[5]  
Kawamori H, 2010, J INVASIVE CARDIOL, V22, P541
[6]  
Lermusiaux P, 2000, J MAL VASCUL, V25, P229
[7]   American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS) - A report of the American College of Cardiology Task Force on Clinical Expert Consensus - Documents developed in collaboration with the European Society of Cardiology endorsed by the Society of Cardiac Angiography and Interventions [J].
Mintz, GS ;
Nissen, SE ;
Anderson, WD ;
Bailey, SR ;
Erbel, R ;
Fitzgerald, PJ ;
Pinto, FJ ;
Rosenfield, K ;
Siegel, RJ ;
Tuzcu, EM ;
Yock, PG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (05) :1478-1492
[8]   Expert review document part 2: methodology, terminology and clinical applications of optical coherence tomography for the assessment of interventional procedures [J].
Prati, Francesco ;
Guagliumi, Giulio ;
Mintz, Gary S. ;
Costa, Marco ;
Regar, Evelyn ;
Akasaka, Takashi ;
Barlis, Peter ;
Tearney, Guillermo J. ;
Jang, Ik-Kyung ;
Arbustini, Elosia ;
Bezerra, Hiram G. ;
Ozaki, Yukio ;
Bruining, Nico ;
Dudek, Darius ;
Radu, Maria ;
Erglis, Andrejs ;
Motreff, Pascale ;
Alfonso, Fernando ;
Toutouzas, Kostas ;
Gonzalo, Nieves ;
Tamburino, Corrado ;
Adriaenssens, Tom ;
Pinto, Fausto ;
Serruys, Patrick W. J. ;
Di Mario, Carlo .
EUROPEAN HEART JOURNAL, 2012, 33 (20) :2513-+
[9]   Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis [J].
Prati, Francesco ;
Regar, Evelyn ;
Mintz, Gary S. ;
Arbustini, Eloisa ;
Di Mario, Carlo ;
Jang, Ik-Kyung ;
Akasaka, Takashi ;
Costa, Marco ;
Guagliumi, Giulio ;
Grube, Eberhard ;
Ozaki, Yukio ;
Pinto, Fausto ;
Serruys, Patrick W. J. .
EUROPEAN HEART JOURNAL, 2010, 31 (04) :401-415
[10]  
Ramesh S, 2012, J INVASIVE CARDIOL, V24, P111