Surface AFM Microscopy of Unworn and Worn Samples of Silicone Hydrogel Contact Lenses

被引:31
作者
Gonzalez-Meijome, J. M. [1 ]
Lopez-Alemany, A. [2 ]
Almeida, J. B. [2 ]
Parafita, M. A. [3 ]
机构
[1] Univ Minho, Sch Sci, Dept Phys Optometry, Braga, Portugal
[2] Univ Valencia, Dept Opt, Valencia, Spain
[3] Univ Santiago de Compostela, Sch Opt & Optometry, Dept Surg Ophthalmol, Santiago De Compostela, Spain
关键词
atomic force microscopy; contact lens; degradation; surface characterization; wear; ATOMIC-FORCE MICROSCOPY; PSEUDOMONAS-AERUGINOSA; CONVENTIONAL HYDROGEL; ADHESION; ATTACHMENT; ETAFILCON; OVERWEAR; WEAR;
D O I
10.1002/jbm.b.31153
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose. To evaluate the qualitative and quantitative topographic changes in the surface of worn contact lenses (CLs) of different materials using atomic force microscopy (AFM). Methods. The topography of five different CL materials was evaluated with AFM over a surface of 25 mu m(2) according to previously published experimental setup. Average roughness (R-a) and root mean square (Rms) values were obtained for unworn and worn samples. Results. The R-a, value increased for balafilcon A (11.62-13.68 nm for unworn and worn samples, respectively), lotrafilcon A (3.67-15.01 nm for unworn and worn samples, respectively), lotrafilcon B (4.08-8.42 nm for unworn and worn samples, respectively), galyfilcon A (2.81-14.6 nm for unworn and worn samples, respectively), and comfilcon A (2.87-4.63 mu for unworn and worn samples, respectively). Differences were statistically significant for all lenses except Rms and R-a for comfilcon A, and R-a parameter for balafilcon A (p > 0.05). The least relative increase was observed for some balarilcon A samples and for some of these samples the roughness decreased after the lenses had been worn. Conclusion. The changes in surface roughness between unworn and worn lenses are different for different silicone-hydrogel materials. Overall all CLs increased the degree of surface roughness after being worn, even for very short periods of time. However, for samples of balafilcon A, roughness increases at a lower extent or even can decrease as compared to unworn samples of the same material due to filling of the macropores. (c) 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 88B: 75-82, 2009
引用
收藏
页码:75 / 82
页数:8
相关论文
共 29 条
  • [1] CHARACTERIZATION OF LACRYMAL COMPONENT ACCUMULATION ON WORN SOFT CONTACT-LENS SURFACES BY ATOMIC-FORCE MICROSCOPY
    BAGUET, J
    SOMMER, F
    CLAUDONEYL, V
    DUC, TM
    [J]. BIOMATERIALS, 1995, 16 (01) : 3 - 9
  • [2] IMAGING SURFACES OF HYDROPHILIC CONTACT-LENSES WITH THE ATOMIC FORCE MICROSCOPE
    BAGUET, J
    SOMMER, F
    DUC, TM
    [J]. BIOMATERIALS, 1993, 14 (04) : 279 - 284
  • [3] Beattie Tara K, 2003, Eye Contact Lens, V29, pS40
  • [4] Attachment of Acanthamoeba to first- and second-generation silicone hydrogel contact lenses
    Beattie, TK
    Tomlinson, A
    McFadyen, AK
    [J]. OPHTHALMOLOGY, 2006, 113 (01) : 117 - 125
  • [5] Bhatia Sameer, 1997, CLAO Journal, V23, P264
  • [6] ATTACHMENT OF PSEUDOMONAS TO HUMAN-WORN, DISPOSABLE ETAFILCON-A CONTACT-LENSES
    BOLES, SF
    REFOJO, MF
    LEONG, FL
    [J]. CORNEA, 1992, 11 (01) : 47 - 52
  • [7] Bontempo Andrew R., 1994, CLAO Journal, V20, P242
  • [8] Brennan N., 2000, ICLC, V27, P75, DOI DOI 10.1016/S0892-8967(01)00060-8
  • [9] Bruinsma GM, 2002, INVEST OPHTH VIS SCI, V43, P3646
  • [10] DURAN JA, 1987, ARCH OPHTHALMOL-CHIC, V105, P106