Femoral anteversion assessment: Comparison of physical examination, gait analysis, and EOS biplanar radiography

被引:15
作者
Westberry, David E. [1 ]
Wack, Linda I. [1 ]
Davis, Roy B. [1 ]
Hardin, James W. [2 ]
机构
[1] Shriners Hosp Children Greenville, 950 West Faris Rd, Greenville, SC 29605 USA
[2] Univ South Carolina, Arnold Sch Publ Hlth, 915 Greene St,Room 448, Columbia, SC 29208 USA
关键词
Femoral anteversion; EOS; Biplanar radiographs; 3-D radiographic models; Cerebral palsy; X-RAY SYSTEM; CEREBRAL-PALSY; TIBIAL TORSION; COMPUTED-TOMOGRAPHY; LOWER-EXTREMITY; INTOEING GAIT; CHILDREN; ANGLE; ADOLESCENTS; CT;
D O I
10.1016/j.gaitpost.2018.03.033
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Multiple measurement methods are available to assess transverse plane alignment of the lower extremity. Research question: This study was performed to determine the extent of correlation between femoral anteversion assessment using simultaneous biplanar radiographs and three-dimensional modeling (EOS imaging), clinical hip rotation by physical examination, and dynamic hip rotation assessed by gait analysis. Methods: Seventy-seven patients with cerebral palsy (GMFCS Level I and II) and 33 neurologically typical children with torsional abnormalities completed a comprehensive gait analysis with same day biplanar anterior-posterior and lateral radiographs and three-dimensional transverse plane assessment of femoral anteversion. Correlations were determined between physical exam of hip rotation, EOS imaging of femoral anteversion, and transverse plane hip kinematics for this retrospective review study. Results: Linear regression analysis revealed a weak relationship between physical examination measures of hip rotation and biplanar radiographic assessment of femoral anteversion. Similarly, poor correlation was found between clinical evaluation of femoral anteversion and motion assessment of dynamic hip rotation. Correlations were better in neurologically typical children with torsional abnormalities compared to children with gait dysfunction secondary to cerebral palsy. Significance: Dynamic hip rotation cannot be predicted by physical examination measures of hip range of motion or from three-dimensional assessment of femoral anteversion derived from biplanar radiographs.
引用
收藏
页码:285 / 290
页数:6
相关论文
共 29 条
[1]   Evaluation of rotational gait abnormality in the patients cerebral palsy [J].
Aktas, S ;
Aiona, MD ;
Orendurff, M .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2000, 20 (02) :217-220
[2]   Repeatability of gait data using a functional hip joint centre and a mean helical knee axis [J].
Besier, TF ;
Sturnieks, DL ;
Alderson, JA ;
Lloyd, DG .
JOURNAL OF BIOMECHANICS, 2003, 36 (08) :1159-1168
[3]   Femoral Anteversion in the Hip: Comparison of Measurement by Computed Tomography, Magnetic Resonance Imaging, and Physical Examination [J].
Botser, Itamar B. ;
Ozoude, George C. ;
Martin, Dorea E. ;
Siddiqi, Aheed J. ;
Kuppuswami, Sivaraja ;
Domb, Benjamin G. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2012, 28 (05) :619-627
[4]   Surgical correction of miserable malalignment syndrome [J].
Bruce, WD ;
Stevens, PM .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2004, 24 (04) :392-396
[5]   Effects of plantarflexion on pelvis and lower limb kinematics [J].
Brunner, R. ;
Dreher, T. ;
Romkes, J. ;
Frigo, C. .
GAIT & POSTURE, 2008, 28 (01) :150-156
[6]   Femoral and Tibial Torsion Measurements With 3D Models Based on Low-Dose Biplanar Radiographs in Comparison With Standard CT Measurements [J].
Buck, Florian M. ;
Guggenberger, Roman ;
Koch, Peter P. ;
Pfirrmann, Christian W. A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :W607-W612
[7]   MEASUREMENT ACCURACY OF PROXIMAL FEMORAL GEOMETRY USING BIPLANAR RADIOGRAPHY [J].
BURR, DB ;
COOK, LT ;
MARTIN, NL ;
ASHER, M .
JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1981, 1 (02) :171-179
[8]   The Availability of Radiological Measurement of Femoral Anteversion Angle: Three-Dimensional Computed Tomography Reconstruction [J].
Byun, Ha Young ;
Shin, Heesuk ;
Lee, Eun Shin ;
Kong, Min Sik ;
Lee, Seung Hun ;
Lee, Chang Hee .
ANNALS OF REHABILITATION MEDICINE-ARM, 2016, 40 (02) :237-243
[9]   Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays [J].
Chaibi, Y. ;
Cresson, T. ;
Aubert, B. ;
Hausselle, J. ;
Neyret, P. ;
Hauger, O. ;
de Guise, J. A. ;
Skalli, W. .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2012, 15 (05) :457-466
[10]   A POWER PRIMER [J].
COHEN, J .
PSYCHOLOGICAL BULLETIN, 1992, 112 (01) :155-159