Resonance Frequency Analysis in Assessing Implant Stability: A Retrospective Analysis

被引:14
作者
Chen, Maggie Hsiao-Mei [1 ]
Lyons, Karl [1 ]
Tawse-Smith, Andrew [1 ]
Ma, Sunyoung [1 ]
机构
[1] Univ Otago, Fac Dent, Sir John Walsh Res Inst, POB 56, Dunedin, New Zealand
关键词
DAMPING CAPACITY ASSESSMENT; OSSEOINTEGRATED ORAL IMPLANTS; IMMEDIATELY LOADED IMPLANTS; BONE LEVEL CHANGES; DENTAL IMPLANTS; IN-VITRO; ENDOSSEOUS IMPLANTS; FAILURE RISK; FOLLOW-UP; QUALITY;
D O I
10.11607/ijp.6057
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To retrospectively assess implant stability quotient (ISQ) values in patients who were followed up between 1998 and 2014 and to evaluate any correlations between ISQ and clinical parameters, such as change in marginal bone level (MBL). Materials and Methods: A total of 173 participants (65 men and 108 women; age range 21 to 85 years) and 383 implants were included. Implant location, MBL, and ISQ were recorded at surgery and at various recall times for statistical analysis. Mixed-model analysis was applied to evaluate the impact of clinical and demographic variables (time, implant location, patient gender) on ISQ and the correlation between ISQ and MBL. The level of significance was set at P < .05. Results: Of the 21 failed implants, 20 failed within 1 year of functional loading, resulting in a 10-year cumulative implant survival estimate of 95%. The failed implants had lower ISQs at surgery (52.3 +/- 7.03) and baseline (52.5 +/- 4.20) when compared to surviving implants (63.0 +/- 10.74 at surgery and 62.3 +/- 8.30 at baseline), and the difference was statistically significant at surgery (P < .05). The mean ISQs generally increased over time, but there were various patterns of changes between implants when grouped according to patient gender and implant location. There was no statistically significant correlation between the changes in ISQ and MBL (P = .211), despite an inverse relationship. Conclusion: Low initial ISQ values may help to identify implants at higher risk of failure. There may be various patterns of change over time in addition to an overall increase in ISQ values. Both similar and contradictory findings were found when compared to earlier literature, and a correlation between resonance frequency analysis and MBL change could not be identified. Despite limitations, the present study provides an overview of the clinical performance of RFA based on long-term clinical data.
引用
收藏
页码:317 / 326
页数:10
相关论文
共 50 条
  • [31] Resonance frequency analysis mapping during implant healing using a nanostructured hydroxyapatite surface
    Rosas-Diaz, Jose Carlos
    Malpartida-Carrillo, Violeta
    Cordova-Limaylla, Nancy Edith
    Guerrero, Maria Eugenia
    Palomino-Zorrilla, Jerson Jimmy
    Cervantes-Ganoza, Luis Adolfo
    Cayo-Rojas, Cesar Felix
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2023, 13 (05) : 365 - 372
  • [32] The Relationship Between Peri-Implant Marginal Bone Loss and Resonance Frequency Analysis
    Perez-Pevida, Esteban
    Monteagudo-Villalobos, Ivan
    Chavarri-Prado, David
    Estrada-Martinez, Alejandro
    Beltran-Guijarro, Miguel
    Dieguez-Pereira, Markel
    Brizuela-Velasco, Aritza
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2025, 16 (02)
  • [33] Relationship between dental implant stability determined by resonance frequency analysis measurements and peri-implant vertical defects:: an in vitro study
    Tozum, T. F.
    Turkyilmaz, I.
    McGlumphy, E. A.
    JOURNAL OF ORAL REHABILITATION, 2008, 35 (10) : 739 - 744
  • [34] The Correlation Between Crestal Bone Resorption and Implant Stability During Healing Period Using Resonance Frequency Analysis
    Al-Juboori, Mohammed Jasim
    Bin AbdulRahaman, Shafluzan
    Hassan, Akram
    IMPLANT DENTISTRY, 2013, 22 (04) : 351 - 355
  • [35] Meta-analysis of Methods Used to Assess Implant Stability
    Cehreli, Murat Cavit
    Karasoy, Durdu
    Akca, Kivanc
    Eckert, Steven E.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (06) : 1015 - 1032
  • [36] Analysis of implant stability changes in immediate loading using a laser displacement sensor in vivo and comparison of its sensitivity with that of resonance frequency analysis
    Murakami, Kazuhiro
    Yamamoto, Kazuhiko
    Ishida, Junichi
    Tsutsumi, Sadami
    Kirita, Tadaaki
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (11) : 1341 - 1356
  • [37] ASSESSMENT OF PRIMARY AND SECONDARY IMPLANT STABILITY BY RESONANCE FREQUENCY ANALYSIS IN ANTERIOR AND POSTERIOR SEGMENTS OF MAXILLARY EDENTULOUS RIDGES
    Baftijari, Denis
    Benedetti, Alberto
    Kirkov, Antonio
    Iliev, Aleksandar
    Stamatoski, Aleksandar
    Baftijari, Florent
    Deliverska, Elitsa G.
    Gjorgievska, Elizabeta
    JOURNAL OF IMAB, 2018, 24 (02): : 2058 - 2064
  • [38] Assessing the Impact of Dental Implant Length on Early Failure Rates: A Retrospective Analysis
    Karthikeyan, Bhuvaneshwari
    Kumar, Hanumantha K.
    Sadananda, K.
    Gowdar, Inderjit Murugendrappa
    Sonune, Shital J.
    Helal, Doaa Abdelaziz A.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S2268 - S2270
  • [39] Influence of Bone Quality, Drilling Protocol, Implant Diameter/Length on Primary Stability: An In Vitro Comparative Study on Insertion Torque and Resonance Frequency Analysis
    Farronato, Davide
    Manfredini, Mattia
    Stocchero, Michele
    Caccia, Mattia
    Azzi, Lorenzo
    Farronato, Marco
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (03) : 182 - 189
  • [40] Implant Primary Stability Determined by Resonance Frequency Analysis: Correlation With Insertion Torque, Histologic Bone Volume, and Torsional Stability at 6 Weeks
    Makary, Christian
    Rebaudi, Alberto
    Sammartino, Gilberto
    Naaman, Nada
    IMPLANT DENTISTRY, 2012, 21 (06) : 474 - 480