Resonance Frequency Analysis in Assessing Implant Stability: A Retrospective Analysis

被引:14
|
作者
Chen, Maggie Hsiao-Mei [1 ]
Lyons, Karl [1 ]
Tawse-Smith, Andrew [1 ]
Ma, Sunyoung [1 ]
机构
[1] Univ Otago, Fac Dent, Sir John Walsh Res Inst, POB 56, Dunedin, New Zealand
关键词
DAMPING CAPACITY ASSESSMENT; OSSEOINTEGRATED ORAL IMPLANTS; IMMEDIATELY LOADED IMPLANTS; BONE LEVEL CHANGES; DENTAL IMPLANTS; IN-VITRO; ENDOSSEOUS IMPLANTS; FAILURE RISK; FOLLOW-UP; QUALITY;
D O I
10.11607/ijp.6057
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To retrospectively assess implant stability quotient (ISQ) values in patients who were followed up between 1998 and 2014 and to evaluate any correlations between ISQ and clinical parameters, such as change in marginal bone level (MBL). Materials and Methods: A total of 173 participants (65 men and 108 women; age range 21 to 85 years) and 383 implants were included. Implant location, MBL, and ISQ were recorded at surgery and at various recall times for statistical analysis. Mixed-model analysis was applied to evaluate the impact of clinical and demographic variables (time, implant location, patient gender) on ISQ and the correlation between ISQ and MBL. The level of significance was set at P < .05. Results: Of the 21 failed implants, 20 failed within 1 year of functional loading, resulting in a 10-year cumulative implant survival estimate of 95%. The failed implants had lower ISQs at surgery (52.3 +/- 7.03) and baseline (52.5 +/- 4.20) when compared to surviving implants (63.0 +/- 10.74 at surgery and 62.3 +/- 8.30 at baseline), and the difference was statistically significant at surgery (P < .05). The mean ISQs generally increased over time, but there were various patterns of changes between implants when grouped according to patient gender and implant location. There was no statistically significant correlation between the changes in ISQ and MBL (P = .211), despite an inverse relationship. Conclusion: Low initial ISQ values may help to identify implants at higher risk of failure. There may be various patterns of change over time in addition to an overall increase in ISQ values. Both similar and contradictory findings were found when compared to earlier literature, and a correlation between resonance frequency analysis and MBL change could not be identified. Despite limitations, the present study provides an overview of the clinical performance of RFA based on long-term clinical data.
引用
收藏
页码:317 / 326
页数:10
相关论文
共 50 条
  • [21] Does Implant Design Affect Implant Primary Stability? A Resonance Frequency Analysis-Based Randomized Split-Mouth Clinical Trial
    Gehrke, Sergio Alexandre
    da Silva Neto, Ulisses Tavares
    Del Fabbro, Massimo
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (06) : E281 - E286
  • [22] Analysis of marginal bone loss and implant stability quotient by resonance frequency analysis in different osteointegrated implant systems. Randomized prospective clinical trial
    Diaz-Sanchez, Rosa-Maria
    Delgado-Munoz, Jose-Maria
    Serrera-Figallo, Maria-Angeles
    Gonzalez-Martin, Maria-Isabel
    Torres-Lagares, Daniel
    Gutierrez-Perez, Jose-Luis
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2019, 24 (02): : E260 - E264
  • [23] Resonance Frequency Analysis to Evaluate the Effect of Different Drilling Techniques on Implant Stability at Different Time Intervals: A Randomized Clinical Trial
    Sunny, Greeshma
    Mishra, Sunil K.
    Chowdhary, Ramesh
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (05) : 1055 - +
  • [24] Does the manual insertion torque of smartpegs affect the outcome of implant stability quotients (ISQ) during resonance frequency analysis (RFA)?
    Kaestel, Ingrid
    de Quincey, Giles
    Neugebauer, Joerg
    Sader, Robert
    Gehrke, Peter
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2019, 5 (01)
  • [25] Longitudinal Implant Stability Measurements Based on Resonance Frequency Analysis After Placement in Healed or Regenerated Bone
    Deli, Giorgio
    Petrone, Vincenzo
    De Risi, Valeria
    Tadic, Drazen
    Zafiropoulos, Gregory-George
    JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (04) : 438 - 447
  • [26] Resonance Frequency Analysis: Agreement and Correlation of Implant Stability Quotients Between Three Commercially Available Instruments
    Norton, Michael R.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (01) : 215 - 222
  • [27] Relationship between implant stability measurements obtained by insertion torque and resonance frequency analysis: A systematic review
    Lages, Frederico Santos
    Douglas-de Oliveira, Dhelfeson Willya
    Costa, Fernando Oliveira
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (01) : 26 - 33
  • [28] Is There a Need for Standardization of Tightening Force Used to Connect the Transducer for Resonance Frequency Analysis in Determining Implant Stability?
    Barella Salatti, Debora
    Antonio Pelegrine, Andre
    Gehrke, Sergio
    Teixeira, Marcelo Lucchesi
    Moshaverinia, Alireza
    Moy, Peter Karyen
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (04) : 886 - 890
  • [29] Comparison of implant stability measurements between a resonance frequency analysis device and a modified damping capacity analysis device: an in vitro study
    Lee, Jungwon
    Pyo, Se-Wook
    Cho, Hyun-Jae
    An, Jung-Sub
    Lee, Jae-Hyun
    Koo, Ki-Tae
    Lee, Yong-Moo
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2020, 50 (01) : 56 - 66
  • [30] Parameters of Implant Stability Measurements Based on Resonance Frequency and Damping Capacity: A Comparative Finite Element Analysis
    Winter, Werner
    Moehrle, Stefan
    Holst, Stefan
    Karl, Matthias
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (03) : 532 - 539