Free Water Elimination Diffusion Tractography: A Comparison With Conventional and Fluid-Attenuated Inversion Recovery, Diffusion Tensor Imaging Acquisitions

被引:21
作者
Hoy, Andrew R. [1 ,2 ,3 ]
Kecskemeti, Steven R. [3 ]
Alexander, Andrew L. [2 ,3 ,4 ]
机构
[1] US Navy, Med Serv Corps, Falls Church, VA USA
[2] Univ Wisconsin, Dept Med Phys, Sch Med & Publ Hlth, Madison, WI 53706 USA
[3] Univ Wisconsin, Waisman Lab Brain Imaging & Behav, Madison, WI 53705 USA
[4] Univ Wisconsin, Dept Psychiat, Madison, WI 53706 USA
基金
美国国家卫生研究院;
关键词
FIBER TRACTOGRAPHY; PARAMETERS; TRACKING; BRAIN;
D O I
10.1002/jmri.24925
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: White matter tractography reconstructions using conventional diffusion tensor imaging (DTI) near cerebrospinal fluid (CSF) spaces are often adversely affected by CSF partial volume effects (PVEs). This study evaluates the ability of free water elimination (FWE) DTI methods to minimize the PVE of CSF for deterministic tractography applications. Materials and Methods: Ten healthy individuals were scanned with "traditional," FLAIR (fluid-attenuated inversion recovery), and FWE DTI scans. The fornix, corpus callosum, and cingulum bundles were reconstructed using deterministic tractography. The FWE DTI scan was performed twice to separately match total acquisition time (long FWE) and number of measurements (encoding directions, short FWE) to the FLAIR and " traditional" DTI scans. PVE resolution was determined based on reconstructed tract volume. All reconstructions underwent blinded review for anatomical correctness, symmetry, and completeness. Results: Reconstructions of the fornix demonstrated that the FWE and FLAIR scans produce more complete, anatomically plausible reconstructions than " traditional" DTI. Additionally, the tract reconstructions using FWE-DTI were significantly larger than when FLAIR was used with DTI (P< 0.0005). FLAIR and the FWE methods led to signal-to-noise ratio (SNR) reductions of 33% and 11%, respectively, compared with conventional DTI. The long and short FWE acquisitions did not significantly (P >= 0.31) differ from one another for any of the reconstructed tracts. Conclusion: The FWE diffusion model overcomes CSF PVE without the time, SNR, and volumetric coverage penalties inherent to FLAIR DTI.
引用
收藏
页码:1572 / 1581
页数:10
相关论文
共 50 条
  • [41] Comparison of white matter integrity between autism spectrum disorder subjects and typically developing individuals: a meta-analysis of diffusion tensor imaging tractography studies
    Aoki, Yuta
    Abe, Osamu
    Nippashi, Yasumasa
    Yamasue, Hidenori
    MOLECULAR AUTISM, 2013, 4
  • [42] Ventricular volumetry and free-water corrected diffusion tensor imaging of the anterior thalamic radiation in idiopathic normal pressure hydrocephalus
    Saito, Asami
    Kamagata, Koji
    Ueda, Ryo
    Nakazawa, Misaki
    Andica, Christina
    Irie, Ryusuke
    Nakajima, Madoka
    Miyajima, Masakazu
    Hori, Masaaki
    Tanaka, Fumiaki
    Arai, Hajime
    Aoki, Shigeki
    JOURNAL OF NEURORADIOLOGY, 2020, 47 (04) : 312 - 317
  • [43] Qualitative and Quantitative Comparison of Contrast-Enhanced Fluid-Attenuated Inversion Recovery, Magnetization Transfer Spin Echo, and Fat-Saturation T1-Weighted Sequences in Infectious Meningitis
    Azad, Rajiv
    Tayal, Mohit
    Azad, Sheenam
    Sharma, Garima
    Srivastava, Rajendra Kumar
    KOREAN JOURNAL OF RADIOLOGY, 2017, 18 (06) : 973 - 982
  • [44] High-signal-intensity abnormalities evaluated by 3D fluid-attenuated inversion recovery imaging within the drainage territory of developmental venous anomalies identified by susceptibility-weighted imaging at 3 T
    Umino, Maki
    Maeda, Masayuki
    Matsushima, Nobuyoshi
    Matsuura, Keita
    Yamada, Tomomi
    Sakuma, Hajime
    JAPANESE JOURNAL OF RADIOLOGY, 2014, 32 (07) : 397 - 404
  • [45] Intraoperative use of diffusion tensor imaging-based tractography for resection of gliomas located near the pyramidal tract: comparison with subcortical stimulation mapping and contribution to surgical outcomes
    Vassal, F.
    Schneider, F.
    Nuti, C.
    BRITISH JOURNAL OF NEUROSURGERY, 2013, 27 (05) : 668 - 675
  • [46] Detection of Brain Metastases by 3-Dimensional Magnetic Resonance Imaging at 3 T: Comparison Between T1-Weighted Volume Isotropic Turbo Spin Echo Acquisition and 3-Dimensional T1-Weighted Fluid-Attenuated Inversion Recovery Imaging
    Yoshida, Atsushi
    Tha, Khin Khin
    Fujima, Noriyuki
    Zaitsu, Yuri
    Yoshida, Daisuke
    Tsukahara, Akiko
    Onodera, Shunsuke
    Shirato, Hiroki
    Terae, Satoshi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (01) : 84 - 90
  • [47] Quantifying neuroinflammation within deep gray matter in small vessel disease using diffusion tensor based free-water imaging: a longitudinal study
    Sun, Yawen
    Han, Xu
    Li, Zhenghao
    Qiu, Yage
    Hu, Ying
    Zhang, Yuyao
    Dai, Yongming
    Wei, Hongjiang
    Xu, Qun
    Zhou, Yan
    FRONTIERS IN AGING NEUROSCIENCE, 2024, 16
  • [48] Contrast-enhanced T1-weighted fluid-attenuated inversion-recovery BLADE magnetic resonance Imaging of the brain: An alternative to spin-echo technique for detection of brain lesions in the unsedated pediatric patient?
    Alibek, Sedat
    Adamietz, Boris
    Cavallaro, Alexander
    Stemmer, Alto
    Anders, Katharina
    Kramer, Manuel
    Bautz, Werner
    Staatz, Gundula
    ACADEMIC RADIOLOGY, 2008, 15 (08) : 986 - 995
  • [49] Diffusion Tensor Imaging of Dystrophic Skeletal Muscle: Comparison of Two Segmentation Methods Adapted to Chemical-shift-encoded Water-fat MRI
    Keller, S.
    Wang, Z. J.
    Aigner, A.
    Kim, A. C.
    Golsari, A.
    Kooijman, H.
    Adam, G.
    Yamamura, J.
    CLINICAL NEURORADIOLOGY, 2019, 29 (02) : 231 - 242
  • [50] Comparison of the Added Value of Contrast-Enhanced 3D Fluid-Attenuated Inversion Recovery and Magnetization-Prepared Rapid Acquisition of Gradient Echo Sequences in Relation to Conventional Postcontrast T1-Weighted Images for the Evaluation of Leptomeningeal Diseases at 3T
    Fukuoka, H.
    Hirai, T.
    Okuda, T.
    Shigematsu, Y.
    Sasao, A.
    Kimura, E.
    Hirano, T.
    Yano, S.
    Murakami, R.
    Yamashita, Y.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (05) : 868 - 873