Continuous Glucose Monitoring Devices: Past, Present, and Future Focus on the History and Evolution of Technological Innovation

被引:94
作者
Didyuk, Olesya [1 ]
Econom, Nicolas [2 ]
Guardia, Angelica [2 ]
Livingston, Kelsey [2 ]
Klueh, Ulrike [2 ]
机构
[1] Wayne State Univ, Dept Biol Sci, IBio Integrat Biosci Ctr, Detroit, MI 48202 USA
[2] Wayne State Univ, Biomed Engn, IBio Integrat Biosci Ctr, Detroit, MI USA
关键词
continuous glucose monitoring; diabetes; foreign body reaction; inflammation;
D O I
10.1177/1932296819899394
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The concept of implantable glucose sensors has been promulgated for more than 40years. It is now accepted that continuous glucose monitoring (CGM) increases quality of life by allowing informed diabetes management decisions as a result of more optimized glucose control. The focus of this article is to provide a brief overview of the CGM market history, emerging technologies, and the foreseeable challenges for the next CGM generations as well as proposing possible solutions in an effort to advance the next generation of implantable sensor.
引用
收藏
页码:676 / 683
页数:8
相关论文
共 53 条
[1]   Biosensors for in vivo glucose measurement: can we cross the experimental stage [J].
Abel, PU ;
von Woedtke, T .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12) :1059-1070
[2]   The rise of technology in diabetes care. Not all that is new is necessarily better [J].
Acerini, Carlo .
PEDIATRIC DIABETES, 2016, 17 (03) :168-173
[3]  
American Diabetes Association, 2018, ROL CONT GLUC MON DI
[4]  
[Anonymous], 2017, National Center for Chronic Disease Prevention and Health Promotion: Division of Nutrition, Physical Activity, and Obesity, P1
[5]   First assessment of the performance of an implantable continuous glucose monitoring system through 180 days in a primarily adolescent population with type 1 diabetes [J].
Aronson, Ronnie ;
Abitbol, Alexander ;
Tweden, Katherine S. .
DIABETES OBESITY & METABOLISM, 2019, 21 (07) :1689-1694
[6]  
Bhardwaj Upkar, 2007, J Diabetes Sci Technol, V1, P8
[7]   Nitric oxide release for improving performance of implantable chemical sensors - A review [J].
Cha, Kyoung Ha ;
Wang, Xuewei ;
Meyerhoff, Mark E. .
APPLIED MATERIALS TODAY, 2017, 9 :589-597
[8]   Cost-effectiveness of G5 Mobile continuous glucose monitoring device compared to self-monitoring of blood glucose alone for people with type 1 diabetes from the Canadian societal perspective [J].
Chaugule, Shraddha ;
Graham, Claudia .
JOURNAL OF MEDICAL ECONOMICS, 2017, 20 (11) :1128-1135
[9]   A View Beyond HbA1c: Role of Continuous Glucose Monitoring [J].
Chehregosha, Haleh ;
Khamseh, Mohammad E. ;
Malek, Mojtaba ;
Hosseinpanah, Farhad ;
Ismail-Beigi, Faramarz .
DIABETES THERAPY, 2019, 10 (03) :853-863
[10]   Medical Management of the Diabetic Patient [J].
Clement, Stephen .
CLINICS IN PODIATRIC MEDICINE AND SURGERY, 2019, 36 (03) :349-+