The risk of a second diagnostic window with 4th generation HIV assays: Two cases

被引:16
作者
Niederhauser, C. [1 ]
Stroehle, A. [2 ]
Stolz, M. [1 ]
Mueller, F.
Tinguely, C. [1 ]
机构
[1] Blood Transfus Serv SRC Berne, CH-3008 Bern, Switzerland
[2] Med Lab MCL, Niederwangen, Switzerland
关键词
4th generation HIV assay; Antibody/antigen combined assay; Second diagnostic window; IMMUNODEFICIENCY-VIRUS ANTIGEN; MULTICENTER EVALUATION; SCREENING ASSAY; P24; ANTIGEN; ANTIBODY; SEROCONVERSION; SENSITIVITY; PERFORMANCE;
D O I
10.1016/j.jcv.2009.05.027
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Background: Despite the improved sensitivity of the 4th generation combined antigen/antibody HIV assays, detection of HIV in the early phase of an infection may still be ineffective. Objectives: Description of two cases that highlight the existence of the "second diagnostic window phase" observed with commonly used sensitive 4th generation HIV assays. Study design: Samples were screened with different 4th generation HIV assays. HIV infection was confirmed with an HIV I/II antibody assay, a HIV-1 p24 antigen assay, the INNO-LIA HIV I/II Score Line immunoassay and HIV-1 PCR. Results: In both investigated cases, the limitations of the 4th generation HIV assays within the second diagnostic window were apparent. Conclusions: The overall sensitivity of the commercial 4th generation HIV assays is currently higher than the 3rd generation HIV assays. Nevertheless, the rare occurrence of a second diagnostic window with 4th generation HIV assays strongly suggests that the following up testing algorithms need to be adjusted accordingly. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:367 / 369
页数:3
相关论文
共 17 条
[1]   Shortening of the diagnostic window with a new combined HIV p24 antigen and anti-HIV-1/2/O screening test [J].
Brust, S ;
Duttmann, H ;
Feldner, J ;
Gürtler, L ;
Thorstensson, R ;
Simon, F .
JOURNAL OF VIROLOGICAL METHODS, 2000, 90 (02) :153-165
[2]   Sensitivity of anti-HIV screening assays.: Reevaluation 1999 [J].
Couroucé, AM .
TRANSFUSION CLINIQUE ET BIOLOGIQUE, 1999, 6 (06) :381-394
[3]  
*FACHK LAB DIAGN, 2004, BAG B, V10, P168
[4]   Reduction of the diagnostic window with a new combined p24 antigen and human immunodeficiency virus antibody screening assay [J].
Gürtler, L ;
Mühlbacher, A ;
Michl, U ;
Hofmann, H ;
Paggi, GG ;
Bossi, V ;
Thorstensson, R ;
Villaescusa, RG ;
Eiras, A ;
Hernandez, JM ;
Melchior, W ;
Donie, F ;
Weber, B .
JOURNAL OF VIROLOGICAL METHODS, 1998, 75 (01) :27-38
[5]  
Kabamba MB, 2002, AIDS, V16, P127
[6]   Seven human immunodeficiency virus (HIV) antigen-antibody combination assays: Evaluation of HIV seroconversion sensitivity and subtype detection [J].
Ly, TD ;
Martin, L ;
Daghfal, D ;
Sandridge, A ;
West, D ;
Bristow, R ;
Chalouas, L ;
Qiu, XX ;
Lou, SC ;
Hunt, JC ;
Schochetman, G ;
Devare, SG .
JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (09) :3122-3128
[7]   Evidence for a diagnostic window in fourth generation assays for HIV [J].
Meier, T ;
Knoll, E ;
Henkes, M ;
Enders, G ;
Braun, R .
JOURNAL OF CLINICAL VIROLOGY, 2001, 23 (1-2) :113-116
[8]   Improvement in the performance of HIV screening kits [J].
Perry, K. R. ;
Ramskill, S. ;
Eglin, R. P. ;
Barbara, J. A. J. ;
Parry, J. V. .
TRANSFUSION MEDICINE, 2008, 18 (04) :228-240
[9]   Fourth-generation enzyme-linked immunosorbent assay for the simultaneous detection of human immunodeficiency virus antigen and antibody [J].
Saville, RD ;
Constantine, NT ;
Cleghorn, FR ;
Jack, N ;
Bartholomew, C ;
Edwards, J ;
Gomez, P ;
Blattner, WA .
JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (07) :2518-2524
[10]   Multicenter evaluation of a new, automated enzyme-linked immunoassay for detection of human immunodeficiency virus-specific antibodies and antigen [J].
Sickinger, E ;
Stieler, M ;
Kaufman, B ;
Kapprell, HP ;
West, D ;
Sandridge, A ;
Devare, S ;
Schochetman, G ;
Hunt, JC ;
Daghfal, D .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (01) :21-29