The influence of various automated devices on the shaping ability of Mtwo rotary nickel-titanium instruments

被引:20
作者
Buerklein, S. [1 ]
Schaefer, E. [1 ]
机构
[1] Univ Munster, Dept Operat Dent, D-48149 Munster, Germany
关键词
canal straightening; Mtwo direct; resin blocks; rotary instruments; torque control;
D O I
10.1111/j.1365-2591.2006.01171.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To compare the shaping ability of Mtwo rotary nickel-titanium instruments in simulated curved canals and in curved canals of extracted teeth when set into permanent rotation with two different torque-limited automated devices. Methodology Root canal instrumentation was performed with two different torque-limited automated devices (Mtwo direct handpiece and Endo IT motor) using Mtwo rotary nickel-titanium instruments up to size 35. Simulated canals: 28 degrees and 35 degrees curved canals in resin blocks (n = 20 canals in each group) were prepared. Pre- and post-instrumentation images were recorded and assessment of canal shape was completed with a computer image analysis program. Extracted teeth: a total of 40 curved root canals were divided into two groups, which were balanced with respect to the angle and the radius of canal curvature. Straightening of the canal curvatures was determined with a computer image analysis program. Incidence of canal aberrations, preparation time, changes of working length and instrument failures were recorded both in simulated and real canals and were analysed using the t-test and a chi-square test. Results In simulated canals, instrumentation with Endo IT was significantly faster than with Mtwo direct (P < 0.05). No significant differences between the two devices were noted when all other parameters were assessed (P > 0.05). Only one instrument separated (Mtwo direct) during the enlargement of 28 degrees curved simulated canals. All systems maintained working distance well. Conclusions Both systems respected original root canal curvature well and were safe, indicating that the Mtwo direct handpiece is suitable for preparing curved root canals with the Mtwo instruments.
引用
收藏
页码:945 / 951
页数:7
相关论文
共 50 条
[41]   Shaping Ability, Cyclic Fatigue Resistance and Fractographic Analysis of Hybrid and Reciprocating Nickel Titanium Endodontic Instruments [J].
Drukteinis, Saulius ;
Peciuliene, Vytaute ;
Bendinskaite, Ruta ;
Brukiene, Vilma ;
Maneliene, Rasmute ;
Nedzinskiene, Egle .
METALS, 2020, 10 (02)
[42]   Effect of movement kinematics on the cyclic fatigue resistance of nickel-titanium instruments [J].
Karatas, E. ;
Arslan, H. ;
Buker, M. ;
Seckin, F. ;
Capar, I. D. .
INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (04) :361-364
[43]   Cutting Efficiency of Conventional and Martensitic Nickel-Titanium Instruments for Coronal Flaring [J].
Morgental, Renata Dornelles ;
Vier-Pelisser, Fabiana Vieira ;
Poli Kopper, Patricia Maria ;
Poli de Figueiredo, Jose Antonio ;
Peters, Ove A. .
JOURNAL OF ENDODONTICS, 2013, 39 (12) :1634-1638
[44]   Effect of Fatigue on Torsional Failure of Nickel-Titanium Controlled Memory Instruments [J].
Campbell, Les ;
Shen, Ya ;
Zhou, Hui-min ;
Haapasalo, Markus .
JOURNAL OF ENDODONTICS, 2014, 40 (04) :562-565
[45]   Comparison of Cyclic Fatigue Resistance of Nickel-Titanium Coronal Flaring Instruments [J].
Capar, Ismail Davut ;
Ertas, Huseyin ;
Arslan, Hakan .
JOURNAL OF ENDODONTICS, 2014, 40 (08) :1182-1185
[46]   Metallurgical analysis and fatigue resistance of WaveOne and ProTaper Nickel-Titanium instruments [J].
Pirani, Chiara ;
Ruggeri, Oddone ;
Cirulli, Pier Paolo ;
Pelliccioni, Gian Andrea ;
Gandolfi, Maria Giovanna ;
Prati, Carlo .
ODONTOLOGY, 2014, 102 (02) :211-216
[47]   Shaping ability and cleaning effectiveness of Mtwo versus coated and uncoated EasyShape instruments in severely curved root canals of extracted teeth [J].
Buerklein, S. ;
Hiller, C. ;
Huda, M. ;
Schaefer, E. .
INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (05) :447-457
[48]   Efficiency of rotary nickel-titanium K3 instruments compared with stainless steel hand K-Flexofile.: Part 2.: Cleaning effectiveness and shaping ability in severely curved root canals of extracted teeth [J].
Schäfer, E ;
Schlingemann, R .
INTERNATIONAL ENDODONTIC JOURNAL, 2003, 36 (03) :208-217
[49]   Effect of interrupted motion on the cyclic fatigue resistance of reciprocating nickel-titanium instruments [J].
Keskin, C. ;
Inan, U. ;
Demiral, M. .
INTERNATIONAL ENDODONTIC JOURNAL, 2018, 51 (05) :549-555
[50]   Cone-beam computed tomography analysis of curved root canals after mechanical preparation with three nickel-titanium rotary instruments [J].
Samia MElsherief ;
Mohamed KZayet ;
Ibrahim MHamouda .
TheJournalofBiomedicalResearch, 2013, 27 (04) :326-335