Problematic of intra-abdominal pressure measurement

被引:2
作者
Neumann, P. [1 ]
机构
[1] Evangel Krankenhaus, D-37075 Gottingen, Germany
来源
ANAESTHESIST | 2009年 / 58卷 / 05期
关键词
Intra-abdominal pressure; Abdominal compartment syndrome; Abdominal hypertension; Abdominal perfusion pressure; CLINICAL EXAMINATION; DIAGNOSIS;
D O I
10.1007/s00101-009-1533-0
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Intra-abdominal hypertension (intra-abdominal pressure, IAP > 12 mmHg) is observed in more than 30% of critically ill patients and is of major prognostic relevance. Unfortunately, clinical examination alone does not allow the IAP to be estimated with sufficient accuracy. Consequently, IAP monitoring should be considered if risk factors for intra-abdominal hypertension are present in order to enable early therapeutic intervention. A technically simple estimation of IAP is possible by intravesical pressure measurements. Alternatively, intragastric pressure can be measured continuously and IAP changes can be detected rapidly. In addition the development of IAP values over time can be appreciated more comprehensively compared to single snapshot-like measurements. The goal of IAP monitoring is not to keep the IAP below a certain threshold, but rather to establish a sufficient abdominal perfusion pressure [APP=mean arterial pressure (MAP)-IAP] of 50-60 mmHg. However, no data have yet been provided showing that the routine use of IAP monitoring and APP targeted therapy is able to improve the prognosis of critically ill patients.
引用
收藏
页码:527 / 531
页数:5
相关论文
共 11 条
  • [1] Intraabdominal pressure: A revised method for measurement (vol 186, pg 368, 1998)
    Cheatham, ML
    Safcsak, K
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1998, 186 (05) : 594 - 595
  • [2] Determining normal values for intra-abdominal pressure
    Chionh, Joanne J. L.
    Wei, Benjamin P. C.
    Martin, Jenepher A.
    Opdam, Helen I.
    [J]. ANZ JOURNAL OF SURGERY, 2006, 76 (12) : 1106 - 1109
  • [3] Semicontinuous intra-abdominal pressure measurement using an intragastric Compliance catheter
    De Waele, Jan J.
    Berrevoet, F.
    Reyntjens, K.
    Pletinckx, P.
    De laet, I.
    Hoste, E.
    [J]. INTENSIVE CARE MEDICINE, 2007, 33 (07) : 1297 - 1300
  • [4] Kirkpatrick AW, 2000, CAN J SURG, V43, P207
  • [5] THE RELATIVE MERITS OF VARIOUS METHODS OF INDIRECT MEASUREMENT OF INTRAABDOMINAL PRESSURE AS A GUIDE TO CLOSURE OF ABDOMINAL-WALL DEFECTS
    LACEY, SR
    BRUCE, J
    BROOKS, SP
    GRISWALD, J
    FERGUSON, W
    ALLEN, JE
    JEWETT, TC
    KARP, MP
    COONEY, DR
    [J]. JOURNAL OF PEDIATRIC SURGERY, 1987, 22 (12) : 1207 - 1211
  • [6] A simplified approach to the diagnosis of elevated intra-abdominal pressure
    Lee, SL
    Anderson, JT
    Kraut, EJ
    Wisner, DH
    Wolfe, BM
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2002, 52 (06): : 1169 - 1172
  • [7] Incidence and pyognosis of intyaabdominal hypeytension in a mixed population of critically ill patients: A multiple-center epidemiological study
    Malbrain, MLNG
    Chiumello, D
    Pelosi, P
    Bihari, D
    Innes, R
    Ranieri, VM
    Del Turco, M
    Wilmer, A
    Brienza, N
    Malcangi, V
    Cohen, J
    Japiassu, A
    De Keulenaer, BL
    Daelemans, R
    Jacquet, L
    Laterre, PF
    Frank, G
    de Souza, P
    Cesana, B
    Gattinoni, L
    [J]. CRITICAL CARE MEDICINE, 2005, 33 (02) : 315 - 322
  • [8] Different techniques to measure intra-abdominal pressure (IAP): time for a critical re-appraisal
    Malbrain, MLNG
    [J]. INTENSIVE CARE MEDICINE, 2004, 30 (03) : 357 - 371
  • [9] Schachtrupp A, 2006, ANAESTHESIST, V55, P660, DOI 10.1007/s00101-006-1019-2
  • [10] Evaluation of two novel methods for the direct and continuous measurement of the intra-abdominal pressure in a porcine model
    Schachtrupp, A
    Tons, C
    Fackeldey, V
    Hoer, J
    Reinges, M
    Schumpelick, V
    [J]. INTENSIVE CARE MEDICINE, 2003, 29 (09) : 1605 - 1608