GHB in postmortem toxicology discrimination between endogenous production from exposure using multiple specimens

被引:82
作者
Kintz, P [1 ]
Villain, M [1 ]
Cirimele, V [1 ]
Ludes, B [1 ]
机构
[1] Inst Med Legale, F-67000 Strasbourg, France
关键词
GHB; postmortem; blood; interpretation;
D O I
10.1016/j.forsciint.2004.02.036
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Since gamma-hydroxybutyrate (GHB) is present in both blood and urine of the general population as an endogenous compound, toxicologists must be able to discriminate between these endogenous levels and a concentration resulting from exogenous exposure. The implementation of a cut-off concentration must be done cautiously, due to the wide distribution of endogenous concentrations. To verify the accuracy of a proposed 50 mg/l postmortem blood cut-off, we tested 71 autopsy cases of subjects where the cause of death could exclude GHB exposure. The delay between death and autopsy ranged from 12 to 72 h. GHB was tested by gas chromatography-mass spectrometry (GC-MS) after precipitation. Briefly, 20 mul of blood, bile, or vitreous humor was pipetted in a glass tube, followed by 20 mul of GHB-d(6) and 45 mul of acetonitrile. After vortexing and centrifugation, the supernatant was collected and evaporated to dryness. The residue was derivatized with bis(trimethylsilyl)trifluoroacetamide (BSTFA) with 1% trimethylchlorosilane (TMCS) for 20 min at 70 degreesC. After injection on a 30 m HP5 MS capillary column, GHB (m/z 233, 204, and 147) and GHB-d6 (m/z 239) were identified by MS. GHB tested positive in all the 71 whole blood (cardiac) specimens, with concentrations in the range 0.4-409 mg/l, with a major distribution in the range 10-40 mg/l. A concentration >50 mg/l was observed in 14 cases. As there was no data to support GHB exposure, this was considered as postmortem formation. In order to discriminate this contamination, when available, femoral blood, bile or/and, vitreous humor were tested. The following results were obtained: cardiac blood (55-409 mg/l) versus bile (6.1-238 mg/l) in seven cases; cardiac blood (51-409 mg/l) versus femoral blood (17-44 mg/l) in five cases, and cardiac blood (51-409 mg/l) versus vitreous humor (3.9-2 mg/l) in six cases. It is obvious that bile does not fit the requirements for discrimination and that femoral blood and mostly vitreous humor can be of particular interest. These results demonstrate that a positive (>50 mg/l) postmortem blood GHB concentration cannot support alone drug exposure and that it is essential to document the case with other specimens, including peripheral blood and vitreous humor. (C) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:177 / 181
页数:5
相关论文
共 19 条
[1]  
BASELT RC, 2002, DISPOSITION TOXIC DR, P472
[2]  
Couper FJ, 2001, J FORENSIC SCI, V46, P919
[3]   The possible influence of micro-organisms and putrefaction in the production of GHB in post-mortem biological fluid [J].
Elliott, S ;
Lowe, P ;
Symonds, A .
FORENSIC SCIENCE INTERNATIONAL, 2004, 139 (2-3) :183-190
[4]   The presence of gamma-hydroxybutyric acid (GHB) in postmortem biological fluids [J].
Elliott, S .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2001, 25 (02) :152-152
[5]   Further evidence for the presence of GHB in postmortem biological fluid: Implications for the interpretation of findings [J].
Elliott, SP .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2004, 28 (01) :20-26
[6]  
FERRARA SD, 1995, J FORENSIC SCI, V40, P501
[7]  
Fieler EL, 1998, CLIN CHEM, V44, P692
[8]  
GHYSEL MH, 1999, TOXICORAMA, V11, P1
[9]  
Kalasinsky KS, 2001, J FORENSIC SCI, V46, P728
[10]   Gamma-hydroxybutyric acid: an emerging recreational drug [J].
Kam, PCA ;
Yoong, FFY .
ANAESTHESIA, 1998, 53 (12) :1195-1198