Autonomic arousal index: an automated detection based on peripheral arterial tonometry

被引:82
|
作者
Pillar, G
Bar, A
Shlitner, A
Schnall, R
Shefy, J
Lavie, P
机构
[1] Technion Israel Inst Technol, Bruce Rappaport Fac Med, Sleep Lab, IL-31096 Haifa, Israel
[2] Itamar Med Ltd, Caesarea, Israel
关键词
sleep; autonomic nervous system; arousals; peripheral arterial tonometry; sympathetic activation;
D O I
10.1093/sleep/25.5.541
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Arousals from sleep are associated with increased sympathetic activation and are therefore associated with peripheral vasoconstriction. We hypothesized that digital vasoconstrictions as measured by peripheral arterial tonometery (PAT), combined with an increase in pulse rate, would accurately reflect arousals from sleep, and can provide an autonomic arousal index (AAI). Based on a previously studied group of 40 sleep apnea patients simultaneously recorded by both polysomnography (PSG) and PAT systems, an automated algorithm using the PAT signal (and pulse rate derived from it) was developed for detection of arousals from sleep. This was further validated in a separate group of 96 subjects (85 patients referred with suspected obstructive sleep apnea and 11 healthy volunteers mean age 46.2 +/- 14.4 years, BMI 28.5 +/- 5,4 kg/m(2)). All underwent a whole night PSG with simultaneous PAT recording. The PSG recordings were blindly manually analyzed for arousals based on American Academy of Sleep Medicine (AASM) criteria, while PAT was scored automatically. There was a significant correlation between PSG and PAT arousals (R=0.82, p<0.0001) with a good agreement across a wide range of values, with a ROC curve having an area under the curve (AUC) of 0.88. We conclude that automated analysis of the peripheral arterial tonometry signal can detect EEG arousals from sleep, in a relatively quick and reproducible fashion.
引用
收藏
页码:543 / 549
页数:7
相关论文
共 50 条
  • [1] Assessment of vascular autonomic function using peripheral arterial tonometry
    Hamada, Satomi
    Oono, Ai
    Ishihara, Yuri
    Hasegawa, Yuki
    Akaza, Miho
    Sumi, Yuki
    Inoue, Yoshinori
    Izumiyama, Hajime
    Hirao, Kenzo
    Isobe, Mitsuaki
    Sasano, Tetsuo
    HEART AND VESSELS, 2017, 32 (03) : 260 - 268
  • [2] Assessment of vascular autonomic function using peripheral arterial tonometry
    Satomi Hamada
    Ai Oono
    Yuri Ishihara
    Yuki Hasegawa
    Miho Akaza
    Yuki Sumi
    Yoshinori Inoue
    Hajime Izumiyama
    Kenzo Hirao
    Mitsuaki Isobe
    Tetsuo Sasano
    Heart and Vessels, 2017, 32 : 260 - 268
  • [3] The effect of upper airway obstruction and arousal on peripheral arterial tonometry, in obstructive sleep apnea
    O'Donnell, CP
    Allan, L
    Atkinson, P
    Schwartz, AR
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 166 (07) : 965 - 971
  • [4] Augmentation Index Association With Reactive Hyperemia as Assessed by Peripheral Arterial Tonometry in Hypertension
    Yang, Woo-In
    Park, Sungha
    Youn, Jong-Chan
    Son, Nak Hoon
    Lee, Sang-Hak
    Kang, Seok-Min
    Jang, Yangsoo
    AMERICAN JOURNAL OF HYPERTENSION, 2011, 24 (11) : 1234 - 1238
  • [5] Peripheral arterial tonometry and angiogenic biomarkers in preeclampsia
    Kumer, Kristina
    Premru-Srsen, Tanja
    Fabjan-Vodusek, Vesna
    Tul, Natasa
    Fabjan, Teja
    Osredkar, Josko
    HYPERTENSION IN PREGNANCY, 2018, 37 (04) : 197 - 203
  • [6] Peripheral arterial tonometry, oximetry and actigraphy for ambulatory recording of sleep apnea
    Penzel, T
    Kesper, K
    Pinnow, I
    Becker, HF
    Vogelmeier, C
    PHYSIOLOGICAL MEASUREMENT, 2004, 25 (04) : 1025 - 1036
  • [7] Peripheral arterial tonometry events and electroencephalographic arousals in children
    Tauman, R
    O'Brien, LM
    Mast, BT
    Holbrook, CR
    Gozal, D
    SLEEP, 2004, 27 (03) : 502 - 506
  • [8] Reproducibility of peripheral arterial tonometry measurements in male cardiovascular patients
    Nil, Markus
    Schaefer, Daniela
    Radtke, Thomas
    Saner, Hugo
    Wilhelm, Matthias
    Eser, Prisca
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2014, 44 (11) : 1065 - 1071
  • [9] Reproducibility of peripheral arterial tonometry for the assessment of endothelial function in adults
    Brant, Luisa C. C.
    Barreto, Sandhi M.
    Passos, Valeria M. A.
    Ribeiro, Antonio L. P.
    JOURNAL OF HYPERTENSION, 2013, 31 (10) : 1984 - 1990
  • [10] Ambulatory recording of sleep apnea using peripheral arterial tonometry
    Penzel, T
    Kesper, K
    Ploch, T
    Becker, HF
    Vogelmeier, C
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 3856 - 3859