Simultaneous determination of hydroquinone and catechol using a glassy carbon electrode modified with gold nanoparticles, ZnS/NiS@ZnS quantum dots and L-cysteine

被引:31
作者
Wang, Yong [1 ]
Qu, Jianhang [2 ]
Li, Shufang [1 ]
Dong, Ying [1 ]
Qu, Jianying [1 ]
机构
[1] Henan Univ, Coll Chem & Chem Engn, Inst Environm & Analyt Sci, Kaifeng 475004, Henan, Peoples R China
[2] Henan Univ Technol, Coll Bioengn, Zhengzhou 450000, Henan, Peoples R China
基金
中国国家自然科学基金;
关键词
Gold nanoparticles; L-Cysteine; Quantumdots; Hydroquinone; Catechol; Electrochemical sensor; Cyclic voltammetry; Differential pulse voltammetry; REDUCED GRAPHENE OXIDE; SENSING PLATFORM; COMPOSITE; NANOCOMPOSITE; SENSOR; RESORCINOL; SAMPLES; LIQUID; FILM; QDS;
D O I
10.1007/s00604-015-1568-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe an electrochemical sensor for simultaneous determination of hydroquinone (HQ) and catechol (CC). A glassy carbon electrode (GCE) was modified with gold nanoparticles, L-cysteine, and ZnS/NiS@ZnS quantum dots using a layer-by-layer technique. The materials were characterized by X-ray diffractometry, field emission scanning electron microscopy, and electrochemical impedance and Fourier transform infrared spectroscopy. Cyclic voltammetry and differential pulse voltammetry revealed this modified GCE to represent a highly sensitive sensor for the simultaneous determination of HQ and CC. The anodic peak current for HQ at a working voltage of 80 mV (vs. Ag/AgCl) is related to its concentration in the 0.1 to 300 mu M range (even in the presence of 0.1 mM of CC). The anodic peak current for CC at a working voltage of 184 mV is related to its concentration in the 0.5 to 400 mu M range (even in the presence of 0.1 mM of HQ). The detection limits (at an S/N ratio of 3) are 24 and 71 nM for HQ and CC, respectively. The modified GCE was successfully applied to the determination of HQ and CC in aqueous solutions and gave satisfactory results.
引用
收藏
页码:2277 / 2283
页数:7
相关论文
共 32 条
[1]   Highly sensitive and simultaneous determination of hydroquinone and catechol at poly(thionine) modified glassy carbon electrode [J].
Ahammad, A. J. Saleh ;
Rahman, Md Mahbubur ;
Xu, Guang-Ri ;
Kim, Sunghyun ;
Lee, Jae-Joon .
ELECTROCHIMICA ACTA, 2011, 56 (14) :5266-5271
[2]   Screen-printed Prussian Blue modified electrode for simultaneous detection of hydroquinone and catechol [J].
Buleandra, Mihaela ;
Rabinca, Andreea Alexandra ;
Mihailciuc, Constantin ;
Balan, Adriana ;
Nichita, Cornelia ;
Stamatin, Ioan ;
Ciucu, Anton Alexandru .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 203 :824-832
[3]  
[陈莉莉 Chen Lili], 2004, [分析科学学报, Journal of Analytical Science], V20, P57
[4]   Discrimination and simultaneous determination of hydroquinone and catechol by tunable polymerization of imidazolium-based ionic liquid on multi-walled carbon nanotube surfaces [J].
Feng, Xun ;
Gao, Weiwei ;
Zhou, Shenghai ;
Shi, Hongyan ;
Huang, Hao ;
Song, Wenbo .
ANALYTICA CHIMICA ACTA, 2013, 805 :36-44
[5]   Functionalized CdSe/ZnS QDs for the Detection of Nitroaromatic or RDX Explosives [J].
Freeman, Ronit ;
Finder, Tali ;
Bahshi, Lily ;
Gill, Ron ;
Willner, Itamar .
ADVANCED MATERIALS, 2012, 24 (48) :6416-6421
[6]   CONTROLLED NUCLEATION FOR REGULATION OF PARTICLE-SIZE IN MONODISPERSE GOLD SUSPENSIONS [J].
FRENS, G .
NATURE-PHYSICAL SCIENCE, 1973, 241 (105) :20-22
[7]   A graphene oxide-mesoporous MnO2 nanocomposite modified glassy carbon electrode as a novel and efficient voltammetric sensor for simultaneous determination of hydroquinone and catechol [J].
Gan, Tian ;
Sun, Junyong ;
Huang, Kejing ;
Song, Li ;
Li, Youmei .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 177 :412-418
[8]   Highly stable pyridinic nitrogen doped graphene modified electrode in simultaneous determination of hydroquinone and catechol [J].
Guo, Hui-Lin ;
Peng, San ;
Xu, Jian-Hua ;
Zhao, Yi-Qing ;
Kang, Xiaofeng .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 193 :623-629
[9]   Study on the application of reduced graphene oxide and multiwall carbon nanotubes hybrid materials for simultaneous determination of catechol, hydroquinone, p-cresol and nitrite [J].
Hu, Fangxin ;
Chen, Shihong ;
Wang, Chengyan ;
Yuan, Ruo ;
Yuan, Dehua ;
Wang, Cun .
ANALYTICA CHIMICA ACTA, 2012, 724 :40-46
[10]   Electrochemical sensing of catechol using a glassy carbon electrode modified with a composite made from silver nanoparticles, polydopamine, and graphene [J].
Huang, Ke-Jing ;
Wang, Lan ;
Li, Jing ;
Yu, Meng ;
Liu, Yan-Ming .