Validity of Noninvasive Meibography Systems: Noncontact Meibography Equipped With a Slit-lamp and a Mobile Pen-shaped Meibograph

被引:20
作者
Arita, Reiko [1 ,2 ,3 ]
机构
[1] Itoh Clin, Dept Ophthalmol, Minuma Ku, Saitama 3370042, Japan
[2] Univ Tokyo, Sch Med, Dept Ophthalmol, Tokyo 113, Japan
[3] Keio Univ, Dept Ophthalmol, Tokyo, Japan
关键词
noninvasive meibography; meibomian gland; dry eye; MEIBOMIAN GLAND DYSFUNCTION; TOPICAL ANTIGLAUCOMA MEDICATIONS; BASAL TEAR TURNOVER; DRY EYE; ALLERGIC CONJUNCTIVITIS; OCULAR SURFACE; OPTOMETRIC PRACTICES; QUESTIONNAIRE; EVAPORATION; SYMPTOMS;
D O I
10.1097/ICO.0b013e3182a2c7c6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Meibomian glands (MGs) secrete lipids (meibum) into the tear film and prevent excessive evaporation. MG dysfunction (MGD) is a major cause of evaporative dry eye. Recent studies have demonstrated that evaporative dry eye resulting from MGD is far more common than aqueous-deficient dry eye is. Meibography is the only technique that can be used to observe the structure of MGs in silhouette, by illuminating the eyelids from the skin side, and can detect the morphological abnormalities in MGs. However, conventional meibography uses a transilluminating light probe directly applied onto the eyelid and thus is invasive. To assess this problem, we developed 2 noninvasive meibography systems (a slit-lamp type and mobile type). In this review, various clinical applications of noninvasive meibography systems are demonstrated. Changes in MGs were examined in contact lens wearers or in patients with allergic conjunctivitis, MGD, aqueous-deficient dry eye, or long-term antiglaucoma eye drop use. The use of a noninvasive meibography system could detect morphological changes such as dropout, shortening, dilation, and distortion of MGs in patients. The ability to detect detailed changes of MGs using noninvasive meibography enhances the power to diagnose MGD and correctly decide the most effective treatment for patients with MGD.
引用
收藏
页码:S65 / S70
页数:6
相关论文
共 32 条
[1]   Noncontact infrared meibography to document age-related changes of the meibomian glands in a normal population [J].
Arita, Reiko ;
Itoh, Kouzo ;
Inoue, Kenji ;
Amano, Shiro .
OPHTHALMOLOGY, 2008, 115 (05) :911-915
[2]   A Newly Developed Noninvasive and Mobile Pen-Shaped Meibography System [J].
Arita, Reiko ;
Itoh, Kouzo ;
Maeda, Shuji ;
Maeda, Koshi ;
Amano, Shiro .
CORNEA, 2013, 32 (03) :242-247
[3]   Comparison of the Long-Term Effects of Various Topical Antiglaucoma Medications on Meibomian Glands [J].
Arita, Reiko ;
Itoh, Kouzo ;
Maeda, Shuji ;
Maeda, Koshi ;
Furuta, Ayumu ;
Tomidokoro, Atsuo ;
Aihara, Makoto ;
Amano, Shiro .
CORNEA, 2012, 31 (11) :1229-1234
[4]   Effects of long-term topical anti-glaucoma medications on meibomian glands [J].
Arita, Reiko ;
Itoh, Kouzo ;
Maeda, Shuji ;
Maeda, Koshi ;
Furuta, Ayumu ;
Tomidokoro, Atsuo ;
Aihara, Makoto ;
Amano, Shiro .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (08) :1181-1185
[5]   Meibomian Gland Duct Distortion in Patients With Perennial Allergic Conjunctivitis [J].
Arita, Reiko ;
Itoh, Kouzo ;
Maeda, Shuji ;
Maeda, Koshi ;
Furuta, Ayumu ;
Tomidokoro, Atsuo ;
Amano, Shiro .
CORNEA, 2010, 29 (08) :858-860
[6]   Proposed Diagnostic Criteria for Obstructive Meibomian Gland Dysfunction [J].
Arita, Reiko ;
Itoh, Kouzo ;
Maeda, Syuji ;
Maeda, Koshi ;
Furuta, Ayumu ;
Fukuoka, Shima ;
Tomidokoro, Atsuo ;
Amano, Shiro .
OPHTHALMOLOGY, 2009, 116 (11) :2058-2063
[7]   Contact Lens Wear Is Associated with Decrease of Meibomian Glands [J].
Arita, Reiko ;
Itoh, Kouzo ;
Inoue, Kenji ;
Kuchiba, Aya ;
Yamaguchi, Takuhiro ;
Amano, Shiro .
OPHTHALMOLOGY, 2009, 116 (03) :379-384
[8]  
Barr J, 2005, ANN REPORT
[9]   Short term comparative study of topical 2% carteolol with and without benzalkonium chloride in healthy volunteers [J].
Baudouin, C ;
de Lunardo, C .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (01) :39-42
[10]   Responses of contact lens wearers to a dry eye survey [J].
Begley, CG ;
Caffery, B ;
Nichols, KK ;
Chalmers, R .
OPTOMETRY AND VISION SCIENCE, 2000, 77 (01) :40-46