Experimental Execution of the Simulated Pivot-Shift Test: A Systematic Review of Techniques

被引:22
作者
Arilla, Fabio V. [1 ,3 ,5 ]
Yeung, Marco [4 ]
Bell, Kevin [2 ,3 ]
Rahnemai-Azar, Ata A. [1 ,3 ]
Rothrauff, Benjamin B. [1 ,3 ]
Fu, Freddie H. [1 ]
Debski, Richard E. [2 ,3 ]
Ayeni, Olufemi R. [4 ]
Musahl, Volker [1 ,2 ,3 ]
机构
[1] Univ Pittsburgh, Dept Orthopaed Surg, Pittsburgh, PA 15203 USA
[2] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA 15203 USA
[3] Univ Pittsburgh, Orthopaed Robot Lab, Pittsburgh, PA 15203 USA
[4] McMaster Univ, Med Ctr, Div Orthopaed Surg, Hamilton, ON, Canada
[5] Univ Hosp Canoas, Dept Orthopaed Surg, Canoas, RS, Brazil
关键词
ANTERIOR CRUCIATE LIGAMENT; ANATOMIC DOUBLE-BUNDLE; SINGLE-BUNDLE; DEFICIENT KNEE; IN-VITRO; BIOMECHANICAL ANALYSIS; BIPLANAR PHOTOGRAPHY; ACL RECONSTRUCTION; ILIOTIBIAL BAND; TUNNEL POSITION;
D O I
10.1016/j.arthro.2015.06.027
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To conduct a systematic review to identify and summarize the various techniques that have been used to simulate the pivot-shift test in vitro. Methods: Medline, Embase, and the Cochrane Library were screened for studies involving the simulated pivot-shift test in human cadaveric knees published between 1946 and May 2014. Study parameters including sample size, study location, simulated pivot-shift technique, loads applied, knee flexion angles at which simulated pivot shift was tested, and kinematic evaluation tools were extracted and analyzed. Results: Forty-eight studies reporting simulated pivot-shift testing on 627 cadaveric knees fulfilled the criteria. Reviewer inter-rater agreement for study selection showed a kappa score of 0.960 (full-text review). Twenty-seven studies described the use of internal rotation torque, with a mean of 5.3 Nm (range, 1 to 18 Nm). Forty-seven studies described the use of valgus torque, with a mean of 8.8 Nm (range, 1 to 25 Nm). Four studies described the use of iliotibial tract tension, ranging from 10 to 88 N. Regarding static simulated pivot-shift test techniques, 100% of the studies performed testing at 30 degrees of knee flexion, and the most tested range of motion in the continuous tests was 0 degrees to 90 degrees. Anterior tibial translation was the most analyzed parameter during the simulated pivot-shift test, being used in 45 studies. In 22% of the studies, a robotic system was used to simulate the pivot-shift test. Robotic systems were shown to have better control of the loading system and higher tracking system accuracy. Conclusions: This study provides a reference for investigators who desire to apply simulated pivot shift in their in vitro studies. It is recommended to simulate the pivot-shift test using a 10-Nm valgus torque and 5-Nm internal rotation torque. Knee flexion of 30 degrees is mandatory for testing.
引用
收藏
页码:2445 / U403
页数:12
相关论文
共 70 条
[1]   Kinematic Impact of Anteromedial and Posterolateral Bundle Graft Fixation Angles on Double-Bundle Anterior Cruciate Ligament Reconstructions [J].
Anderson, Colin J. ;
Westerhaus, Benjamin D. ;
Pietrini, Sean D. ;
Ziegler, Connor G. ;
Wijdicks, Coen A. ;
Johansen, Steinar ;
Engebretsen, Lars ;
LaPrade, Robert F. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2010, 38 (08) :1575-1583
[2]   Comparison of three non-invasive quantitative measurement systems for the pivot shift test [J].
Araujo, Paulo H. ;
Ahlden, Mattias ;
Hoshino, Yuichi ;
Muller, Bart ;
Moloney, Gele ;
Fu, Freddie H. ;
Musahl, Volker .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (04) :692-697
[3]   Pivot shift as an outcome measure for ACL reconstruction: a systematic review [J].
Ayeni, Olufemi R. ;
Chahal, Manraj ;
Tran, Michael N. ;
Sprague, Sheila .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (04) :767-777
[4]   Effect of Tunnel Position and Graft Size in Single-Bundle Anterior Cruciate Ligament Reconstruction: An Evaluation of Time-Zero Knee Stability [J].
Bedi, Asheesh ;
Maak, Travis ;
Musahl, Volker ;
O'Loughlin, Padhraig ;
Choi, Dan ;
Citak, Musa ;
Pearle, Andrew D. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2011, 27 (11) :1543-1551
[5]   Effect of Tibial Tunnel Position on Stability of the Knee After Anterior Cruciate Ligament Reconstruction Is the Tibial Tunnel Position Most Important? [J].
Bedi, Asheesh ;
Maak, Travis ;
Musahl, Volker ;
Citak, Musa ;
O'Loughlin, Padhraig F. ;
Choi, Daniel ;
Pearle, Andrew D. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2011, 39 (02) :366-373
[6]   A Comparison of the Effect of Central Anatomical Single-Bundle Anterior Cruciate Ligament Reconstruction and Double-Bundle Anterior Cruciate Ligament Reconstruction on Pivot-Shift Kinematics [J].
Bedi, Asheesh ;
Musahl, Volker ;
O'Loughlin, Padhraig ;
Maak, Travis ;
Citak, Musa ;
Dixon, Peter ;
Pearle, Andrew D. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2010, 38 (09) :1788-1794
[7]   Lateral compartment translation predicts the grade of pivot shift: a cadaveric and clinical analysis [J].
Bedi, Asheesh ;
Musahl, Volker ;
Lane, Clayton ;
Citak, Musa ;
Warren, Russell F. ;
Pearle, Andrew D. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (09) :1269-1276
[8]   Clinical diagnosis of an anterior cruciate ligament rupture: A meta-analysis [J].
Benjammse, A ;
Gokeler, A ;
van der Schans, CP .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2006, 36 (05) :267-288
[9]  
Bull AMJ, 1999, CLIN ORTHOP RELAT R, P219
[10]   Influence of the valgus force during knee flexion in neutral rotation [J].
Citak, Musa ;
O'Loughlin, Padhraig F. ;
Citak, Mustafa ;
Suero, Eduardo M. ;
Bosscher, Marianne R. F. ;
Musahl, Volker ;
Pearle, Andrew D. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (08) :1571-1574