Femtomolar detection of cardiac troponin I using a novel label-free and reagent-free dendrimer enhanced impedimetric immunosensor

被引:51
|
作者
Akter, Rashida [1 ]
Jeong, Bongjin [1 ]
Lee, Yong-Mi [1 ]
Choi, Jong-Soon [1 ,2 ]
Rahman, Md. Aminur [1 ]
机构
[1] Chungnam Natl Univ, Grad Sch Analyt Sci & Technol, GRAST, Daejeon 34134, South Korea
[2] Korea Basic Sci Inst, Div Life Sci, Daejeon 34133, South Korea
基金
新加坡国家研究基金会;
关键词
Impedimetric immunosensor; Dendrimer; 3; 5; '-Tetramethylbenzidine; Protein biomarkers; Cardiac troponin I; Human serum; ELECTROCHEMICAL IMMUNOSENSOR; GOLD NANOPARTICLES; CANCER BIOMARKERS; GRAPHENE; PROTEIN; BIOSENSOR; PLATFORM; ARRAY;
D O I
10.1016/j.bios.2017.01.021
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel highly sensitive dendrimer coupled impedimetric immunosensor was developed for the label-free and reagent-free detection of cardiac troponin I (TnI) in serum samples. The immunosensor probe was fabricated by covalently attaching carboxylic acid-functionalized third generation (G3) poly (amidoamine) (PAMAM) dendrimer (Den) on the 3, 3', 5, 5'-tetramethyl benzidine (TMB) modified 6-mercaptohexanoic acid (MHA) self-assembled monolayer (SAM) on a gold (Au) electrode. Monoclonal anti-TnI antibody was then covalently immobilized on the Den and TMB attached MHA SAM modified surface. TMB was used as an internal surface redox couple for generating signal which also allowed to avoid the use of an external one (i.e. ferricyanide couple) in solution during the impedance measurement for monitoring the antibody-antigen binding. On the other hand, Den was used as a signal enhancer by immobilizing more anti-body on the immunosensor probe. The immunosensor probe was characterized using X-ray photoelectron spectroscopy (XPS), quartz crystal microbalance (QCM), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS) techniques. The TnI detection in diluted serum was based on the measurement of charge transfer resistance (R-ct) of the electron transfer process of the surface -attached TMB before and after immunobinding. Under the optimized condition, the proposed immunosensor could detect human TnI in diluted serum samples as low as 11.7 fM with a wide linear dynamic range, good stability, and excellent specificity. The validity of the proposed method was tested in various TnI spiked human undiluted serum samples and was compared with the enzyme -linked immunosorbent assay (ELISA). The results suggested that the proposed immunosensor could be a useful tool for practical applications in clinical diagnosis.
引用
收藏
页码:637 / 643
页数:7
相关论文
共 50 条
  • [1] Label-Free Immunosensor Based on Liquid Crystal and Gold Nanoparticles for Cardiac Troponin I Detection
    Zapp, Eduardo
    Brondani, Daniela
    Silva, Tania Regina
    Girotto, Edivandro
    Gallardo, Hugo
    Vieira, Iolanda Cruz
    BIOSENSORS-BASEL, 2022, 12 (12):
  • [2] Label-Free Specific Detection of Femtomolar Cardiac Troponin Using an Integrated Nanoslit Array Fluidic Diode
    Liu, Yifan
    Yobas, Levent
    NANO LETTERS, 2014, 14 (12) : 6983 - 6990
  • [3] Development of a label-free impedimetric immunosensor for the detection of respiratory syncytial virus
    Stefanne e Silva, Tallita
    Oliveira e Freitas, Guilherme Ramos
    Ferreira, Lucas Franco
    Franco, Diego Leoni
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2024, 28 (11) : 4015 - 4027
  • [4] Development of a novel label-free amperometric immunosensor for the detection of okadaic acid
    Hayat, Akhtar
    Barthelmebs, Lise
    Sassolas, Audrey
    Marty, Jean-Louis
    ANALYTICA CHIMICA ACTA, 2012, 724 : 92 - 97
  • [5] Label-free immunosensor for cardiac troponin I detection based on aggregation-induced electrochemiluminescence of a distyrylarylene derivative
    Yan, Mengxia
    Feng, Sinuo
    Yu, Linying
    Xue, Yu
    Huang, Jianshe
    Yang, Xiurong
    BIOSENSORS & BIOELECTRONICS, 2021, 192
  • [6] A MXene-functionalized paper-based electrochemical immunosensor for label-free detection of cardiac troponin I
    Wang, Li
    Han, Yufeng
    Wang, Hongchen
    Han, Yaojie
    Liu, Jinhua
    Lu, Gang
    Yu, Haidong
    JOURNAL OF SEMICONDUCTORS, 2021, 42 (09)
  • [7] Mucin 4 detection with a label-free electrochemical immunosensor
    Hosu, Oana
    Tertis, Mihaela
    Melinte, Gheorghe
    Feier, Bogdan
    Sandulescu, Robert
    Cristea, Cecilia
    ELECTROCHEMISTRY COMMUNICATIONS, 2017, 80 : 39 - 43
  • [8] Enhancement of label-free biosensing of cardiac troponin I
    Christenson, Chase
    Baryeh, Kwaku
    Ahadian, Samad
    Nasiri, Rohollah
    Dokmeci, Mehmet R.
    Goudie, Marcus
    Khademhosseini, Ali
    Ye, Jing Yong
    LABEL-FREE BIOMEDICAL IMAGING AND SENSING (LBIS) 2020, 2020, 11251
  • [9] A novel label-free electrochemical immunosensor for the detection of hepatitis B surface antigen
    Tian, Lihui
    Liu, Li
    Li, Yueyuan
    Feng, Xue
    Wei, Qin
    Cao, Wei
    ANALYTICAL METHODS, 2016, 8 (40) : 7380 - 7386
  • [10] A label-free impedimetric immunosensor for direct determination of the textile dye Disperse Orange 1
    Yang, Jing
    da Rocha, Carolina Gomes
    Wang, Shengfu
    Pupim Ferreira, Antonio Aparecido
    Yamanaka, Hideko
    TALANTA, 2015, 142 : 183 - 189