Real-time ultrasound transducer localization in fluoroscopy images by transfer learning from synthetic training data

被引:28
作者
Heimann, Tobias [1 ]
Mountney, Peter [2 ]
John, Matthias [3 ]
Ionasec, Razvan [2 ]
机构
[1] Siemens AG, Corp Technol Imaging & Comp Vis, Erlangen, Germany
[2] Siemens Corp, Corp Technol Imaging & Comp Vis, Princeton, NJ USA
[3] Siemens AG, Healthcare Sect, Forchheim, Germany
关键词
Transfer learning; Domain adaptation; Object localization; Fluoroscopy; Ultrasound; X-RAY FLUOROSCOPY; COVARIATE SHIFT; REGISTRATION;
D O I
10.1016/j.media.2014.04.007
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The fusion of image data from trans-esophageal echography (TEE) and X-ray fluoroscopy is attracting increasing interest in minimally-invasive treatment of structural heart disease. In order to calculate the needed transformation between both imaging systems, we employ a discriminative learning (DL) based approach to localize the TEE transducer in X-ray images. The successful application of DL methods is strongly dependent on the available training data, which entails three challenges: (1) the transducer can move with six degrees of freedom meaning it requires a large number of images to represent its appearance, (2) manual labeling is time consuming, and (3) manual labeling has inherent errors. This paper proposes to generate the required training data automatically from a single volumetric image of the transducer. In order to adapt this system to real X-ray data, we use unlabeled fluoroscopy images to estimate differences in feature space density and correct covariate shift by instance weighting. Two approaches for instance weighting, probabilistic classification and Kullback-Leibler importance estimation (KLIEP), are evaluated for different stages of the proposed DL pipeline. An analysis on more than 1900 images reveals that our approach reduces detection failures from 7.3% in cross validation on the test set to zero and improves the localization error from 1.5 to 0.8 mm. Due to the automatic generation of training data, the proposed system is highly flexible and can be adapted to any medical device with minimal efforts. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:1320 / 1328
页数:9
相关论文
共 20 条
[11]   A Survey on Transfer Learning [J].
Pan, Sinno Jialin ;
Yang, Qiang .
IEEE TRANSACTIONS ON KNOWLEDGE AND DATA ENGINEERING, 2010, 22 (10) :1345-1359
[12]   Improving predictive inference under covariate shift by weighting the log-likelihood function [J].
Shimodaira, H .
JOURNAL OF STATISTICAL PLANNING AND INFERENCE, 2000, 90 (02) :227-244
[13]  
Sugiyama M., 2010, RIMS Kokyuroku, V1703, P10
[14]   Direct importance estimation for covariate shift adaptation [J].
Sugiyama, Masashi ;
Suzuki, Taiji ;
Nakajima, Shinichi ;
Kashima, Hisashi ;
von Buenau, Paul ;
Kawanabe, Motoaki .
ANNALS OF THE INSTITUTE OF STATISTICAL MATHEMATICS, 2008, 60 (04) :699-746
[15]   Dimensionality reduction for density ratio estimation in high-dimensional spaces [J].
Sugiyama, Masashi ;
Kawanabe, Motoaki ;
Chui, Pui Ling .
NEURAL NETWORKS, 2010, 23 (01) :44-59
[16]  
Tu ZW, 2005, IEEE I CONF COMP VIS, P1589
[17]   Robust real-time face detection [J].
Viola, P ;
Jones, MJ .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 2004, 57 (02) :137-154
[18]  
Yamada M, 2012, LECT NOTES COMPUT SC, V7575, P674, DOI 10.1007/978-3-642-33765-9_48
[19]   Four-Chamber Heart Modeling and Automatic Segmentation for 3-D Cardiac CT Volumes Using Marginal Space Learning and Steerable Features [J].
Zheng, Yefeng ;
Barbu, Adrian ;
Georgescu, Bogdan ;
Scheuering, Michael ;
Comaniciu, Dorin .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (11) :1668-1681
[20]  
Zhu X., 2008, 1530 U WISCONSIN MAD