Bedside Sonographic Measurement of Optic Nerve Sheath Diameter as a Predictor of Increased Intracranial Pressure in Children

被引:132
作者
Le, Audrey [1 ]
Hoehn, Mary Ellen [2 ]
Smith, Mary E. [2 ]
Spentzas, Thomas [1 ]
Schlappy, David [1 ]
Pershad, Jay [1 ]
机构
[1] Univ Tennessee, Ctr Hlth Sci, Dept Pediat, Le Bonheur Childrens Med Ctr, Memphis, TN 38163 USA
[2] Univ Tennessee, Ctr Hlth Sci, Dept Ophthalmol, Le Bonheur Childrens Med Ctr, Memphis, TN 38163 USA
关键词
ULTRASONOGRAPHY; ULTRASOUND;
D O I
10.1016/j.annemergmed.2008.11.025
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: We investigate the test performance of emergency physician-performed sonographic measurement of optic nerve sheath diameter for diagnosis of increased intracranial pressure. Methods: Children between the ages of 0 and 18 years with suspected increased intracranial pressure were prospectively recruited from the emergency department and ICU of an urban, tertiary-level, freestanding pediatric facility. Pediatric emergency physicians with goal-directed training in ophthalmic sonography measured optic nerve sheath diameter. Images were recorded and subsequently reviewed by a pediatric ophthalmologist and an ophthalmic sonographer, both of whom were blind to the patient's clinical condition. Measurements obtained by the ophthalmic sonographer were considered the criterion standard. An optic nerve sheath diameter greater than 4.0 mm in subjects younger than 1 year and greater than 4.5 mm in older children was considered abnormal. The diagnosis of increased intracranial pressure was based on results of cranial imaging or direct measurement of intracranial pressure. Results: Sixty-four patients were recruited, of whom 24 (37%) had a confirmed diagnosis of increased intracranial pressure. The sensitivity of optic nerve sheath diameter as a screening test for increased intracranial pressure was 83% (95% confidence interval [CI] 0.60 to 0.94); specificity was 38% (95% CI 0.23 to 0.54); positive likelihood ratio was 1.32 (95% CI 0.97 to 1.79) and negative likelihood ratio was 0.46 (95% CI 0.18 to 1.23). There was fair to good interobserver agreement between the pediatric emergency physician and ophthalmic sonographer (kappa 0.52) and pediatric ophthalmologist (kappa 0.64). Conclusion: The sensitivity and specificity of bedside sonographic measurement of optic nerve sheath diameter is inadequate to aid medical decisionmaking in children with suspected increased intracranial pressure. Pediatric emergency physicians with focused training by a pediatric ophthalmologist familiar with ophthalmic sonography can measure optic nerve sheath diameter accurately. [Ann Emerg Med. 2009;53:785-791.]
引用
收藏
页码:785 / 791
页数:7
相关论文
共 13 条
[1]   Transorbital optic nerve sheath ultrasonography in normal children [J].
Ballantyne, J ;
Hollman, AS ;
Hamilton, R ;
Bradnam, MS ;
Carachi, R ;
Young, DG ;
Dutton, GN .
CLINICAL RADIOLOGY, 1999, 54 (11) :740-742
[2]  
Biros MH., 1998, EMERGENCY MED CONCEP, P416
[3]   Elevated intracranial pressure detected by bedside emergency ultrasonography of the optic nerve sheath [J].
Blaivas, M ;
Theodoro, D ;
Sierzenski, PR .
ACADEMIC EMERGENCY MEDICINE, 2003, 10 (04) :376-381
[4]   COMPUTER-AIDED AREA MEASUREMENT OF OCULAR IMAGES [J].
GOSBELL, AD ;
BARRY, WR ;
FAVILLA, I ;
TURNER, IJ .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1987, 15 (04) :341-348
[5]   Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: Ultrasound findings during intrathecal infusion tests [J].
Hansen, HC ;
Helmke, K .
JOURNAL OF NEUROSURGERY, 1997, 87 (01) :34-40
[6]   Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension .2. Patient study [J].
Helmke, K ;
Hansen, HC .
PEDIATRIC RADIOLOGY, 1996, 26 (10) :706-710
[7]   Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure [J].
Kimberly, Heidi Harbison ;
Shah, Sachita ;
Marill, Keith ;
Noble, Vicki .
ACADEMIC EMERGENCY MEDICINE, 2008, 15 (02) :201-204
[8]   Sonography of the optical nerve -: Experience in 483 children [J].
Körber, F ;
Scharf, M ;
Moritz, J ;
Dralle, D ;
Alzen, G .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (02) :229-235
[9]   MEASUREMENT AND RELATIONSHIP OF SUBARACHNOID PRESSURE OF THE OPTIC-NERVE TO INTRACRANIAL PRESSURES IN FRESH CADAVERS [J].
LIU, D ;
KAHN, M .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1993, 116 (05) :548-556
[10]   Sonographic evaluation of optic nerve diameter in children with raised intracranial pressure [J].
Malayeri, AA ;
Bavarian, S ;
Mehdizadeh, M .
JOURNAL OF ULTRASOUND IN MEDICINE, 2005, 24 (02) :143-147