Radiographic and clinical results of tension suture fixation using two washers with PHILOS plate for proximal humeral fractures

被引:9
作者
Cho, Chul-Hyun [1 ]
Kim, Du Han [1 ]
Kim, Beom-Soo [1 ]
机构
[1] Keimyung Univ, Dongsan Med Ctr, Pain Res Ctr, Sch Med,Dept Orthoped Surg, Daegu, South Korea
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2017年 / 48卷 / 02期
关键词
Proximal humerus; Fracture; Suture fixation; Plate; EARLY COMPLICATIONS; INTERNAL-FIXATION; LOCKING PLATE; FAILURE; 3-PART;
D O I
10.1016/j.injury.2016.11.030
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: The purpose of this study was to evaluate the radiographic and clinical results of tension suture fixation using two washers with PHILOS plate (Synthes, West Chester, PA, USA) for proximal humeral fractures. Patients and methods: Consecutive 39 patients were included and divided into two groups of adequate and inadequate medial support (MS (+) group vs MS (-) group). The mean follow-up period was 45months (range: 26-69 months). The mean age at the time of surgery was 59 years ( range: 17-86 years) and there were 12 men and 27 women. The clinical results were evaluated using the visual analogue scale (VAS) pain score, American Shoulder and Elbow Surgeons (ASES) score, and subjective shoulder value (SSV). The radiographic results were evaluated by serial radiographs and Paavolainen method, which measures the neck-shaft angle (NSA). We used the Paired T and Kruskal-Wallis test to compare radiographic and clinical results between the two groups. Results: Bony union was achieved in 37 cases (94.9%). The mean NSA was changed from 133.5(circle) postoperatively to 131.0(circle) at the final follow- up period, but this change was not statistically significant. Thirty- five cases (89.8%) had good radiographic results as determined by the Paavolainen method. The mean final VAS pain score, ASES score, and SSV were 1.3, 87.3, and 86.0%, respectively. There were no significant differences between the two groups with respect to radiographic and clinical outcomes. Eight cases (20.5%) had complications including 5 with shoulder stiffness, 1 experiencing nonunion by fixation failure, 1 malunion, and 1 migration of greater tuberosity. Conclusion: Tension suture fixation using two washers with PHILOS plate for proximal humeral fractures yielded satisfactory radiographic and clinical results. It can be a treatment option that can reduce varus deformity and fixation loss. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:464 / 468
页数:5
相关论文
共 25 条
[1]   Analysis of efficacy and failure in proximal humerus fractures treated with locking plates [J].
Agudelo, Juan ;
Schuermann, Matthias ;
Stahel, Philip ;
Helwig, Peter ;
Morgan, Steven J. ;
Zechel, Wolfgang ;
Bahrs, Christian ;
Parekh, Anand ;
Ziran, Bruce ;
Williams, Allison ;
Smith, Wade .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (10) :676-681
[2]   Complications encountered in proximal humerus fractures treated with locking plate fixation [J].
Aksu, Neslihan ;
Gogus, Abdullah ;
Kara, Ayhan Nedim ;
Isiklar, Zekeriya Ugur .
ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2010, 44 (02) :89-96
[3]   Results of proximal humeral locked plating with supplemental suture fixation of rotator cuff [J].
Badman, Brian ;
Frankle, Mark ;
Keating, Christopher ;
Henderson, Leanne ;
Brooks, Jordan ;
Mighell, Mark .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (04) :616-624
[4]   Open Reduction and Internal Fixation of Proximal Humerus Fractures Using a Proximal Humeral Locked Plate: A Prospective Multicenter Analysis [J].
Brunner, Felix ;
Sommer, Christoph ;
Bahrs, Christian ;
Hettwinkel, Rainer ;
Hafner, Christian ;
Rillmann, Paavo ;
Kohut, Georges ;
Ekelund, Anders ;
Muller, Mathias ;
Audige, Laurent ;
Babst, Reto .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (03) :163-172
[5]   Tension Suture Fixation Using 2 Washers for Proximal Humeral Fractures [J].
Cho, Chul-Hyun ;
Jung, Gu-Hee ;
Song, Kwang-Soon .
ORTHOPEDICS, 2012, 35 (03) :202-205
[6]   Biomechanics of locked plates and screws [J].
Egol, KA ;
Kubiak, EN ;
Fulkerson, E ;
Kummer, FJ ;
Koval, KJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) :488-493
[7]   Early complications in proximal humerus fractures (OTA types 11) treated with locked plates [J].
Egol, Kenneth A. ;
Ong, Crispin C. ;
Walsh, Michael ;
Dazrawi, Laith M. ;
Tejwani, Nirmal C. ;
Zuckerman, Joseph D. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (03) :159-164
[8]  
Esser RD, 1994, CLIN ORTHOP RELAT R, V24, P4
[9]   Proximal humerus fracture rotational stability after fixation using a locking plate or a fixed-angle locked nail: The role of implant stiffness [J].
Foruria, Antonio M. ;
Teresa Carrascal, Maria ;
Revilla, Carlos ;
Munuera, Luis ;
Sanchez-Sotelo, Joaquin .
CLINICAL BIOMECHANICS, 2010, 25 (04) :307-311
[10]   The importance of medial support in locked plating of proximal humerus fractures [J].
Gardner, Michael J. ;
Weil, Yoram ;
Barker, Joseph U. ;
Kelly, Bryan T. ;
Helfet, David L. ;
Lorich, Dean G. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (03) :185-191