Impedimetric biosensors

被引:261
作者
Guan, JG [1 ]
Miao, YQ
Zhang, QJ
机构
[1] Wuhan Univ Technol, State Key Lab Adv Technol Mat Synth & Proc, Wuhan 430070, Peoples R China
[2] Zhejiang Normal Univ, Coll Chem & Life Sci, Jinhua 321004, Peoples R China
关键词
impedimetric biosensors; biosensors; electrochemical impedimetric spectroscopy; electrochemical biosensors;
D O I
10.1016/s1389-1723(04)70195-4
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Electrochemical impedance spectroscopy (EIS) is a sensitive indicator of a wide variety of chemical and physical properties. An increasing trend towards the development of impedimetric biosensors is being currently observed. Impedimetric techniques have been performed to characterize the fabrication of the biosensors and to monitor the catalyzed reactions of enzymes or the biomolecular recognition events of specific binding proteins, lectins, receptors, nucleic acids, whole cells, antibodies or antibody-related substances. However, little attention has been paid to reviewing this interesting research area. Herein, impedimetric biosensors are reviewed and many novel designs are discussed.
引用
收藏
页码:219 / 226
页数:8
相关论文
共 47 条
  • [1] Ellipsometry measurements and impedance spectroscopy on Langmuir-Blodgett membranes on Si/SiO2 for ion sensitive sensor
    Abdelmalek, F
    Shadaram, M
    Boushriha, H
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (03) : 208 - 213
  • [2] Molecular imprinting: developments and applications in the analytical chemistry field
    Andersson, LI
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2000, 745 (01): : 3 - 13
  • [3] Berggren C, 2001, ELECTROANAL, V13, P173, DOI 10.1002/1521-4109(200103)13:3<173::AID-ELAN173>3.0.CO
  • [4] 2-B
  • [5] Bott A.W., 2001, CURR SEP, V19, P71
  • [6] An EIS study of DNA-modified electrodes
    Brett, CMA
    Brett, AMO
    Serrano, SHP
    [J]. ELECTROCHIMICA ACTA, 1999, 44 (24) : 4233 - 4239
  • [7] Cady P., 1978, MECHANIZING MICROBIO, P199
  • [8] Functionalization of Si/SiO2 substrates with homooligonucleotides for a DNA biosensor
    Cloarec, JP
    Martin, JR
    Polychronakos, C
    Lawrence, I
    Lawrence, MF
    Souteyrand, E
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1999, 58 (1-3) : 394 - 398
  • [9] DETECTION OF ESCHERICHIA-COLI IN POTABLE WATER USING DIRECT IMPEDANCE TECHNOLOGY
    COLQUHOUN, KO
    TIMMS, S
    FRICKER, CR
    [J]. JOURNAL OF APPLIED BACTERIOLOGY, 1995, 79 (06): : 635 - 639
  • [10] Layer-by-layer assembly of multilayer films composed of avidin and biotin-labeled antibody for immunosensing
    Cui, XQ
    Pei, RJ
    Wang, XZ
    Yang, F
    Ma, Y
    Dong, SJ
    Yang, XR
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 18 (01) : 59 - 67