Single-drop microextraction followed by in-syringe derivatization and GC-MS detection for the determination of parabens in water and cosmetic products

被引:87
作者
Saraji, Mohammad [1 ]
Mirmahdieh, Shiva [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
关键词
Cosmetics; GC-MS; In-syringe derivatization; Parabens; Single-drop microextraction; SOLID-PHASE EXTRACTION; CHROMATOGRAPHY-MASS-SPECTROMETRY; MICELLAR ELECTROKINETIC CHROMATOGRAPHY; PERFORMANCE LIQUID-CHROMATOGRAPHY; GAS-CHROMATOGRAPHY; HUMAN HEALTH; PRESERVATIVES; SAMPLES; PESTICIDES; BUTYL;
D O I
10.1002/jssc.200800635
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A single-drop microextraction (SDME) method followed by in-syringe derivatization and GC-MS determination has been developed for analysis of five parabens, including methyl, ethyl, isopropyl, n-propyl and n-butyl paraben in water samples and cosmetic products. N,O-Bis(trimethylsilyl)acetamide (BSA) was used as derivatization reagent. Derivatization reaction was performed inside the syringe barrel using 0.4 mu L of BSA. Parameters that affect the derivatization yield such as temperature and time of the reaction were studied. In addition, experimental SDME parameters such as selection of organic solvent, addition of salt, extraction time and extraction temperature were investigated and optimized. The RSD of the method for aqueous samples varied from 8.1 to 13%. The LODs ranged from 0.001 (n-butyl paraben) to 0.015 (methyl paraben) mu g/L, and the enrichment factors were between 23 and 150.
引用
收藏
页码:988 / 995
页数:8
相关论文
共 35 条
[1]   Determination of cisapride, its oxidation product, propyl and butyl parabens in pharmaceutical dosage form by reversed-phase liquid chromatography [J].
Belgaied, JE ;
Trabelsi, H .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (05) :991-998
[2]   Validation of HPLC analysis of 2-phenoxyethanol, 1-phenoxypropan-2-ol, methyl, ethyl, propyl, butyl and benzyl 4-hydroxybenzoate (parabens) in cosmetic products, with emphasis on decision limit and detection capability [J].
Borremans, M ;
Van Loco, J ;
Roos, P ;
Goeyens, L .
CHROMATOGRAPHIA, 2004, 59 (1-2) :47-53
[3]   Optimisation of a solid-phase microextraction method for the determination of parabens in water samples at the low ng per litre level [J].
Canosa, P. ;
Rodriguez, I. ;
Rubi, E. ;
Bollain, M. H. ;
Cela, R. .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1124 (1-2) :3-10
[4]   Paraben esters: review of recent studies of endocrine toxicity, absorption, esterase and human exposure, and discussion of potential human health risks [J].
Darbre, Philippa D. ;
Harvey, Philip W. .
JOURNAL OF APPLIED TOXICOLOGY, 2008, 28 (05) :561-578
[5]   Antibacterial effect of parabens against planktonic and biofilm Streptococcus sobrinus [J].
Doron, S ;
Friedman, M ;
Falach, M ;
Sadovnic, E ;
Zvia, H .
INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2001, 18 (06) :575-578
[6]   A review of the endocrine activity of parabens and implications for potential risks to human health [J].
Golden, R ;
Gandy, J ;
Vollmer, G .
CRITICAL REVIEWS IN TOXICOLOGY, 2005, 35 (05) :435-458
[7]   Multiresidue method for the simultaneous determination of four groups of pesticides in ground and drinking waters, using solid-phase microextraction -: gas chromatography with electron-capture and thermionic specific detection [J].
Gonçalves, C ;
Alpendurada, MF .
JOURNAL OF CHROMATOGRAPHY A, 2002, 968 (1-2) :177-190
[8]  
Halket JM., 1993, HDB DERIVATIVES CHRO
[9]   On-line pretreatment and determination of parabens in cosmetic products by combination of flow injection analysis, solid-phase extraction and micellar electrokinetic chromatography [J].
Han, Fang ;
He, You-Zhao ;
Yu, Chang-Zhu .
TALANTA, 2008, 74 (05) :1371-1377
[10]   Regulation of endocrine-disrupting chemicals: Critical overview and deficiencies in toxicology and risk assessment for human health [J].
Harvey, PW ;
Everett, DJ .
BEST PRACTICE & RESEARCH CLINICAL ENDOCRINOLOGY & METABOLISM, 2006, 20 (01) :145-165