Investigations into the use of screen-printed carbon electrodes as templates for electrochemical sensors and sonochemically fabricated microelectrode arrays

被引:21
作者
Gornall, Davinia D. [1 ]
Collyer, Stuart D. [2 ]
Higson, Seamus P. J. [1 ]
机构
[1] Cranfield Univ, Cranfield MK43 0AL, Beds, England
[2] Microarray Ltd, Manchester M60 1QD, Lancs, England
关键词
Carbon ink; Pre-treatment; Sensors; Electroactivity; PASTE ELECTRODES; VOLTAMMETRIC ANALYSIS; GRAPHITE-ELECTRODES; FILM ELECTRODES; BIOSENSORS; POLYANILINE; SURFACE; INKS;
D O I
10.1016/j.snb.2009.06.051
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The paper critically evaluates the suitability of carbon inks as hosts for the fabrication and subsequent mass production of sonochemically produced microelectrode arrays. Two commercially available carbon inks (GEM and Dupont) were compared in terms of electroactivity towards standard redox couples, and their electroanalytical response was investigated in terms of reversibility, operational potential range, background currents and steady-state response characteristics. Following on from these findings, the inks were then subjected to simple activation and modification procedures (comprising of electrochemical, chemical and physical treatments), with a view to maximising the electrode response, in terms of how modifications to the carbon surface translate into changes in the performance characteristics of the electrodes. The results from these investigations are discussed in the context of the use of pre-treated carbon surfaces for the enhanced production of sonochemically fabricated microelectrode array sensors, for use as electrochemical sensors and biosensors. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:581 / 591
页数:11
相关论文
共 36 条
[1]   Ultrasonically enhanced voltammetric analysis and applications: An overview [J].
Banks, CE ;
Compton, RG .
ELECTROANALYSIS, 2003, 15 (5-6) :329-346
[2]   Sonochemically fabricated microelectrode arrays for biosensors offering widespread applicability: Part I [J].
Barton, AC ;
Collyer, SD ;
Davis, F ;
Gornall, DD ;
Law, KA ;
Lawrence, ECD ;
Mills, DW ;
Myler, S ;
Pritchard, JA ;
Thompson, M ;
Higson, SPJ .
BIOSENSORS & BIOELECTRONICS, 2004, 20 (02) :328-337
[3]   Sonoelectrochemical processes: A review [J].
Compton, RG ;
Eklund, JC ;
Marken, F .
ELECTROANALYSIS, 1997, 9 (07) :509-522
[4]   ELECTROCHEMICAL EXAMINATION OF UNUSUAL PROPERTIES OF SPECTROSCOPIC GRAPHITE-ELECTRODES [J].
COURY, LA ;
HEINEMAN, WR .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 256 (02) :327-341
[5]   Effect of pre-treatment on the surface and electrochemical properties of screen-printed carbon paste electrodes [J].
Cui, G ;
Yoo, JH ;
Lee, JS ;
Yoo, J ;
Uhm, JH ;
Cha, GS ;
Nam, H .
ANALYST, 2001, 126 (08) :1399-1403
[6]   THE EFFECT OF PH ON SOME OUTER-SPHERE ELECTRODE-REACTIONS AT CARBON ELECTRODES [J].
DEAKIN, MR ;
STUTTS, KJ ;
WIGHTMAN, RM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 182 (01) :113-122
[7]   ULTRASONIC HYDRODYNAMIC MODULATION VOLTAMMETRY [J].
DEWALD, HD ;
PETERSON, BA .
ANALYTICAL CHEMISTRY, 1990, 62 (07) :779-782
[8]   Recent developments in the field of screen-printed electrodes and their related applications [J].
Dominguez Renedo, O. ;
Alonso-Lomillo, M. A. ;
Arcos Martinez, M. J. .
TALANTA, 2007, 73 (02) :202-219
[9]   Flexible amperometric transducers for biosensors based on a screen printed three electrode system [J].
Erlenkötter, A ;
Kottbus, M ;
Chemnitius, GC .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 481 (01) :82-94
[10]   Development and evaluation of electrochemical glucose enzyme biosensors based on carbon film electrodes [J].
Florescu, M ;
Brett, CMA .
TALANTA, 2005, 65 (02) :306-312