Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation

被引:56
作者
Alfonso, Jose F. [1 ,2 ]
Lisa, Carlos [1 ]
Palacios, Ana [1 ]
Fernandes, Paulo [3 ]
Gonzalez-Meijome, Jose M. [3 ]
Montes-Mico, Robert [4 ]
机构
[1] Inst Oftalmol Fernandez Vega, Oviedo 33012, Spain
[2] Univ Oviedo, Sch Med, Dept Surg, Oviedo, Spain
[3] Univ Minho, Sch Sci, Dept Phys Optometry, Braga, Portugal
[4] Univ Valencia, Fac Phys, Dept Opt, Valencia, Spain
关键词
PHAKIC INTRAOCULAR-LENS; OPTICAL COHERENCE TOMOGRAPHY; ADMINISTRATION CLINICAL-TRIAL; POSTERIOR CHAMBER LENSES; CONTACT-LENS; ANTERIOR SEGMENT; CATARACT FORMATION; FOLLOW-UP; MODERATE; OPACITIES;
D O I
10.1016/j.ajo.2009.01.006
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the relationship between subjective measurements of vault and objective values measured with Visante optical coherence tomography (OCT) in eyes receiving an implantable contact lens (ICL) for myopia correction. DESIGN: Observational cross-sectional study. METHODS: SETTING: Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. PATIENTS: Four hundred and fifty-two eyes from 246 patients were elected to be implanted with a Visian ICL V4 (STAAR Surgical Inc, Monrovia, California, USA). OBSERVATION PROCEDURES: Subjective and objective measurements of vault after implantation of ICL. MAIN OUTCOME MEASURES: Subjective vault classified in 5 levels assessed using an optical section during slit-lamp examination. Objective vault was measured with Visante OCT (Carl Zeiss Meditec Inc, Dublin, California, USA). RESULTS: Average values of objective and subjective vault were 414 +/- 228 mu m and 2.1 +/- 1.0, respectively and both parameters were highly correlated (r=0.82; P<.001). Differences in average objective vault were statistically significant among the 5 groups of subjective vault (P<.001). Subjective vault 0 corresponded to a mean OCT value of 62 49 mu m with 99% confidence interval (CI) [38; 86] mu m; eyes with vault 1 to 203 +/- 93 mu m with 99% CI [176; 230] mu m; eyes with vault 2 to 402 +/- 131 mu m with 99% CI [378; 425] mu m; eyes with vault 3 to 594 +/- 146 mu m, 99% CI [554; 633] mu m; and vault 4 to 794 +/- 182 mu m with 99% CI [713; 875] mu m. CONCLUSIONS: Subjective and objective values of vault are highly correlated. In 99% of cases within the CI, objective values for eyes subjectively classified within a certain level vary within a narrow interval (+/- 25 to 80 mu m) around the mean value, and this interval is characteristic of each subjective level. (Am J Ophthalmol 2009;147:978-983. (C) 2009 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:978 / 983
页数:6
相关论文
共 27 条
[1]   Myopic Phakic STAAR Collamer Posterior Chamber Intraocular Lenses for Keratoconus [J].
Alfonso, Jose F. ;
Palacios, Ana ;
Montes-Mico, Robert .
JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (09) :867-874
[2]   Phakic posterior chamber lenses for high myopia: Functional and anatomical outcomes [J].
Arne, JL ;
Lesueur, LC .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (03) :369-374
[3]   Contact between 3 phakic intraocular lens models and the crystalline lens: An anterior chamber optical coherence tomography study [J].
Baikoff, G ;
Wei, LJ ;
Ferraz, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (09) :2007-2012
[4]   Static and dynamic analysis of the anterior segment with optical coherence tomography [J].
Baikoff, G ;
Lutun, E ;
Ferraz, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (09) :1843-1850
[5]   Imaging of posterior chamber phakic intraocular lens by optical coherence tomography [J].
Bechmann, M ;
Ullrich, S ;
Thiel, MJ ;
Kenyon, KR ;
Ludwig, K .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :360-363
[6]   Pigmentary dispersion syndrome induced by a posterior chamber phakic refractive lens [J].
Brandt, JD ;
Mockovak, ME ;
Chayet, A .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2001, 131 (02) :260-263
[7]   Phakic posterior chamber intraocular lens pupillary block [J].
Bylsma, SS ;
Zalta, AH ;
Foley, E ;
Osher, RH .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (12) :2222-2228
[8]  
Choi KH, 2007, J REFRACT SURG, V23, P362
[9]   Iris and trabecular meshwork pigment changes after posterior chamber phakic intraocular lens implantation [J].
Chun, Yeoun Sook ;
Park, In Ki ;
Lee, Hyeon Il ;
Lee, Jong Ho ;
Kim, Jae Chan .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (09) :1452-1458
[10]  
ELIES D, 2004, PROTOCOLOS IMPLANTE, P30