Performance evaluation of a visual guidance patient-controlled respiratory gating system for respiratory-gated magnetic-resonance image-guided radiation therapy

被引:1
|
作者
Choun, Hyung Jin [1 ,3 ]
Kim, Jung-in [2 ,3 ,4 ]
Choi, Chang Heon [2 ,3 ,4 ]
Jung, Seongmoon [2 ,3 ]
Jin, Hyeongmin [2 ,3 ]
Wu, Hong-Gyun [2 ,3 ,4 ,5 ]
Chie, Eui Kyu [2 ,3 ,4 ,5 ]
Park, Jong Min [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Seoul Natl Univ, Interdisciplinary Program Bioengn, Seoul, South Korea
[2] Seoul Natl Univ Hosp, Dept Radiat Oncol, Seoul, South Korea
[3] Seoul Natl Univ Hosp, Biomed Res Inst, Seoul, South Korea
[4] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, Seoul, South Korea
[5] Seoul Natl Univ, Dept Radiat Oncol, Coll Med, Seoul, South Korea
[6] Adv Inst Convergence Technol, Robot Res Lab Extreme Environm, Suwon, South Korea
基金
新加坡国家研究基金会;
关键词
Respiratory-gated radiotherapy; Breath-hold; Treatment efficiency; Visual guidance; STEREOTACTIC BODY RADIOTHERAPY; MOTION;
D O I
10.1007/s13246-022-01144-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The performance of a visual guidance patient-controlled (VG-PC) respiratory gating system for magnetic-resonance (MR) image-guided radiation therapy (MR-IGRT) was evaluated through a clinical trial of patients with either lung or liver cancer. Patients can voluntarily control their respiration utilizing the VG-PC respiratory gating system. The system enables patients to view near-real-time cine planar MR images projected inside the bore of MR-IGRT systems or an external screen. Twenty patients who had received stereotactic ablative radiotherapy (SABR) for lung or liver cancer were prospectively selected for this study. Before the first treatment, comprehensive instruction on the VG-PC respiratory gating system was provided to the patients. Respiratory-gated MR-IGRT was performed for each patient with it in the first fraction and then without it in the second fraction. For both the fractions, the total treatment time, beam-off time owing to the respiratory gating, and number of beam-off events were analyzed. The average total treatment time, beam-off time, and number of beam-off events with the system were 1507.3 s, 679.5 s, and 185, respectively, and those without the system were 2023.7 s (p < 0.001), 1195.0 s (p < 0.001), and 380 times (p < 0.001), respectively. The VG-PC respiratory gating system improved treatment efficiency through a reduction in the beam-off time, the number of beam-off events, and consequently the total treatment time when performing respiratory-gated MR-IGRT for lung and liver SABR.
引用
收藏
页码:809 / 816
页数:8
相关论文
共 3 条
  • [1] Performance evaluation of a visual guidance patient-controlled respiratory gating system for respiratory-gated magnetic-resonance image-guided radiation therapy
    Hyung Jin Choun
    Jung-in Kim
    Chang Heon Choi
    Seongmoon Jung
    Hyeongmin Jin
    Hong-Gyun Wu
    Eui Kyu Chie
    Jong Min Park
    Physical and Engineering Sciences in Medicine, 2022, 45 : 809 - 816
  • [2] Development of patient-controlled respiratory gating system based on visual guidance for magnetic-resonance image-guided radiation therapy
    Kim, Jung-in
    Lee, Hanyoung
    Wu, Hong-Gyun
    Chie, Eui Kyu
    Kang, Hyun-Cheol
    Park, Jong Min
    MEDICAL PHYSICS, 2017, 44 (09) : 4838 - 4846
  • [3] Safety and Efficacy of Neoadjuvant SABR in Pancreatic Cancer: Effect of Magnetic Resonance Imaging-Guided Respiratory-Gated Adaptive Radiation Therapy
    Song, Jun Yeong
    Kim, Yong-Tae
    Ryu, Ji Kon
    Lee, Sang Hyub
    Paik, Woo Hyun
    Cho, In Rae
    Kim, Hongbeom
    Kwon, Wooil
    Jang, Jin-Young
    Chie, Eui Kyu
    Kang, Hyun-Cheol
    ADVANCES IN RADIATION ONCOLOGY, 2024, 9 (01)