A novel upgrade to Helsinki AMS: Fast switching of isotopes with electrostatic deflectors

被引:7
作者
Palonen, V. [1 ]
Tikkanen, P. [1 ]
机构
[1] Univ Helsinki, Dept Phys, FI-00014 Helsinki, Finland
关键词
Accelerator mass spectrometry; Sequential injection of isotopic beams; Deflectors; Automation; Synchronization; SYSTEM;
D O I
10.1016/j.nimb.2015.04.053
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have developed and installed electrostatic deflectors at the injection magnet entrance and exit to enable fast switching between isotopes in AMS measurements. The fast selection of the injected isotope, stable isotope current measurements, and rare isotope detection are all performed with three synchronized real-time NI-PXI computers. With the improvements, we are able to attain a precision of better than 0.2% for the C-14/C-13 ratio of modern samples. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:263 / 266
页数:4
相关论文
共 12 条
  • [1] COMPUTATIONAL ASPECTS OF OPTICS DESIGN AND SIMULATION - COSY INFINITY
    BERZ, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 298 (1-3) : 473 - 479
  • [2] Instrumentation for the in situ control of carrier recombination characteristics during irradiation by protons
    Gaubas, E.
    Uleckas, A.
    Vaitkus, J.
    Raisanen, J.
    Tikkanen, P.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (05)
  • [3] Temperature sensitivity of decomposition in a peat profile
    Hilasvuori, E.
    Akujarvi, A.
    Fritze, H.
    Karhu, K.
    Laiho, R.
    Makiranta, P.
    Oinonen, M.
    Palonen, V.
    Vanhala, P.
    Liski, J.
    [J]. SOIL BIOLOGY & BIOCHEMISTRY, 2013, 67 : 47 - 54
  • [4] Temperature-induced ageing of solar absorbers on plain and anodized aluminium substrates
    Kotilainen, M.
    Mizohata, K.
    Honkanen, M.
    Hyvarinen, L.
    Vuoristo, P.
    [J]. SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2015, 134 : 244 - 251
  • [5] Manura D, 2008, SIMION R 8 0 USER MA
  • [6] Improving AMS uncertainties and detection of instrumental error
    Palonen, V.
    Tikkanen, P.
    Keinonen, J.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (7-8) : 972 - 975
  • [7] A Bayesian measurement model; reliable uncertainties and control over instrumental drift
    Palonen, V.
    Tikkanen, P.
    Keinonen, J.
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2008, 41 (21)
  • [8] Palonen V., NUCL INSTR M B UNPUB
  • [9] A fast bouncing system for the high-energy end of AMS
    Sie, SH
    Sims, DA
    Niklaus, TR
    Suter, GF
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 172 : 268 - 273
  • [10] AMS facility at the University of Helsinki
    Tikkanen, P
    Palonen, V
    Jungner, H
    Keinonen, J
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 223 : 35 - 39