Separate Vertical Wiring for the Fixation of Comminuted Fractures of the Inferior Pole of the Patella

被引:58
|
作者
Song, Hyung Keun [1 ]
Yoo, Je Hyun [2 ]
Byun, Young Soo [3 ]
Yang, Kyu Hyun [4 ]
机构
[1] Ajou Univ, Sch Med, Dept Orthopaed Surg, Suwon 441749, South Korea
[2] Hallym Univ, Sacred Heart Hosp, Dept Orthopaed Surg, Anyang, South Korea
[3] Daegu Fatima Hosp, Dept Orthopaed Surg, Taegu, South Korea
[4] Yonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Orthopaed Surg, Seoul, South Korea
关键词
Patella; inferior pole; vertical wiring; cerclage wiring; INTERNAL-FIXATION;
D O I
10.3349/ymj.2014.55.3.785
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Among patients over 50 years of age, separate vertical wiring alone may be insufficient for fixation of fractures of the inferior pole of the patella. Therefore, mechanical and clinical studies were performed in patients over the age of 50 to test the strength of augmentation of separate vertical wiring with cerclage wire (i.e., combined technique). Materials and Methods: Multiple osteotomies were performed to create four-part fractures in the inferior poles of eight pairs of cadaveric patellae. One patella from each pair was fixed with the separate wiring technique, while the other patella was fixed with a combined technique. The ultimate load to failure and stiffness of the fixation were subsequently measured. In a clinical study of 21 patients (average age of 64 years), comminuted fractures of the inferior pole of the patellae were treated using the combined technique: Operative parameters were recorded from which post-operative outcomes were evaluated. Results: For cadaveric patellae, whose mean age was 69 years, the mean ultimate loads to failure for the separate vertical wiring technique and the combined technique were 216.4 +/- 72.4 N and 324.9 +/- 50.6 N, respectively (p=0.012). The mean stiffness for the separate vertical wiring technique and the combined technique was 241.1 +/- 68.5 N/mm and 340.8 +/- 45.3 N/mm, respectively (p=0.012). In the clinical study, the mean clinical score at final follow-up was 28.1 points. Conclusion: Augmentation of separate vertical wiring with cerclage wire provides enough strength for protected early exercise of the knee joint and uneventful healing.
引用
收藏
页码:785 / 791
页数:7
相关论文
共 50 条
  • [1] Separate vertical wiring plus bilateral anchor girdle suturing fixation for the fractures of the inferior pole of the patella
    Li, Shi-Jie
    Tiwari, Shashi Ranjan
    Chang, Shi-Min
    Du, Shou-Chao
    Zhang, Ying-Qi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [2] Separate vertical wiring plus bilateral anchor girdle suturing fixation for the fractures of the inferior pole of the patella
    Shi-Jie Li
    Shashi Ranjan Tiwari
    Shi-Min Chang
    Shou-Chao Du
    Ying-Qi Zhang
    Journal of Orthopaedic Surgery and Research, 18
  • [3] Modified Technique of Separate Vertical Wiring for the Fixation of Patellar Inferior Pole Fracture
    He, Shuangjian
    Huang, Xiaoyi
    Yan, Bin
    Zhu, Jian
    Bao, Nirong
    Zhao, Jianning
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2018, 32 (04) : e145 - e150
  • [4] Management of comminuted inferior patellar pole fractures with cerclage-wire-augmented separate vertical wiring: a retrospective clinical study
    Yan, Shuang G.
    Li, Di
    Cui, Yiliang
    Hua, Xingyi
    Hemmann, Philipp
    Schmidutz, Florian
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (01) : 247 - 254
  • [5] Management of comminuted inferior patellar pole fractures with cerclage-wire-augmented separate vertical wiring: a retrospective clinical study
    Shuang G. Yan
    Di Li
    Yiliang Cui
    Xingyi Hua
    Philipp Hemmann
    Florian Schmidutz
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 247 - 254
  • [6] Clinical outcome of rim-plate-augmented separate vertical wiring with supplementary fixation for the treatment of patellar fracture associated comminuted inferior pole
    Cho, Won-Tae
    Sakong, Seungyeob
    Sunwoo, Jung
    Choi, Wonseok
    Ryu, Yun-Ki
    Choi, Jeong-Seok
    Oh, Jong-Keon
    Kim, Beom-Soo
    Cho, Jae-Woo
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [7] Patellar Shape-Memory Fixator for the Treatment of Comminuted Fractures of the Inferior Pole of the Patella
    Xin-Wei Liu
    Hui-Juan Shang
    Shuo-Gui Xu
    Zhi-Wei Wang
    Chun-Cai Zhang
    Qing-Ge Fu
    Journal of Materials Engineering and Performance, 2011, 20 : 623 - 628
  • [8] Patellar Shape-Memory Fixator for the Treatment of Comminuted Fractures of the Inferior Pole of the Patella
    Liu, Xin-Wei
    Shang, Hui-Juan
    Xu, Shuo-Gui
    Wang, Zhi-Wei
    Zhang, Chun-Cai
    Fu, Qing-Ge
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2011, 20 (4-5) : 623 - 628
  • [9] A modified separate vertical fixation by wires and titanium cables for comminuted inferior patella fracture: A technique note and finite element analysis
    Gao, Yanchun
    Cheng, Yuan
    Zhu, Hongli
    Wang, Chenchen
    Song, Sa
    Yu, Xingang
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 (06): : 1831 - 1837
  • [10] Suture anchor fixation of comminuted inferior pole patella fracture-novel technique: suture bridge anchor fixation technique
    Kim, Kwang-Sub
    Suh, Dong-Whan
    Park, Sang-Eun
    Ji, Jong-Hun
    Han, Young-Hoon
    Kim, Jae-Hoon
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (11) : 1889 - 1897