HbA1c measurements from dried blood spots: validation and patient satisfaction

被引:56
作者
Fokkema, M. Rebecca [1 ]
Bakker, Andries J. [1 ]
de Boer, Fokje [2 ]
Kooistra, Jeltsje [1 ]
de Vries, Sifra [1 ]
Wolthuis, Albert [1 ]
机构
[1] Med Ctr Leeuwarden, Stichting Klin Chem Lab, Leeuwarden, Netherlands
[2] Hosp Sionsberg, Stichting Klin Chem Lab, Dokkum, Netherlands
关键词
capillary blood; dried blood spots; filter paper; HbA1c; patient satisfaction; POINT-OF-CARE; CAPILLARY BLOOD; FILTER-PAPER; WHOLE-BLOOD; GLYCOSYLATED PROTEIN; COLLECTION; HBA(1C);
D O I
10.1515/CCLM.2009.274
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: This study evaluates HbA1c measurements from dried blood spots collected on filter paper and compares HbA1c from filter paper (capillary blood) with HbA1c measured in venous blood. Methods: Patient satisfaction was evaluated using a questionnaire. The performance with the filter paper method was assessed by comparing HbA1c results from EDTA-blood samples obtained via dried blood spots with HbA1c results obtained with freshly hemolyzed blood (routine HbA1c). Adult patients visiting the outpatient clinic for HbA1c analyses were recruited for the evaluation of dried blood spot sampling at home. Laboratory personnel collected a capillary blood sample on filter paper as well as a venous EDTA-blood sample. The participants collected another capillary blood sample at home and sent the dried filter paper back to the laboratory. Samples were analyzed with an immunoturbidimetric assay. Results: Between-filter coefficient of variation was 1.8%. Filter paper HbA1c increased slightly during storage, particularly during the first 5 days. Filter paper HbA1c highly correlated with routine HbA1c (r=0.987). The evaluation of samples collected at home showed comparable HbA1c values by filter paper and routine sampling methods (n=93). Eighty-three percent of participants said they would like the filter method to be brought into practice. Conclusions: Home HbA1c sampling on filter paper is an acceptable sampling alternative for analysis of HbA1c. Clin Chem Lab Med 2009;47:1259-64.
引用
收藏
页码:1259 / 1264
页数:6
相关论文
共 22 条
[1]  
Am Diabetes Assoc, 2006, DIABETES CARE, V29, pS4
[2]  
Anjali, 2007, J Assoc Physicians India, V55, P115
[3]  
[Anonymous], 2006, HUISARTS WET
[4]   IMPROVED SAMPLE COLLECTION TECHNIQUE FOR CAPILLARY BLOOD ON FILTER-PAPER FOR DETERMINATION OF GLYCATED HEMOGLOBIN [J].
ECKERBOM, S ;
BERGQVIST, Y .
ANNALS OF CLINICAL BIOCHEMISTRY, 1989, 26 :148-150
[5]   COLORIMETRIC MEASUREMENT OF GLYCOSYLATED PROTEIN IN WHOLE-BLOOD, RED-BLOOD-CELLS, PLASMA AND DRIED BLOOD [J].
EROSS, J ;
KREUTZMANN, D ;
JIMENEZ, M ;
KEEN, R ;
ROGERS, S ;
COWELL, C ;
VINES, R ;
SILINK, M .
ANNALS OF CLINICAL BIOCHEMISTRY, 1984, 21 (NOV) :477-483
[6]  
EROSS J, 1986, CLIN CHEM, V32, P2222
[7]   ACCURACY OF A FILTER-PAPER METHOD FOR MEASURING GLYCOSYLATED HEMOGLOBIN [J].
GAY, EC ;
CRUICKSHANKS, KJ ;
CHASE, HP ;
KLINGENSMITH, G ;
HAMMAN, RF .
DIABETES CARE, 1992, 15 (01) :108-110
[8]  
GOLDSTEIN DE, 1982, CLIN CHEM, V28, P386
[9]  
*INT DIAB FED, 2009, FACTS FIG
[10]   Capillary blood on filter paper for determination of HbA(1c) by ion exchange chromatography [J].
Jeppsson, JO ;
Jerntorp, P ;
Almer, LO ;
Persson, R ;
Ekberg, G ;
Sundkvist, G .
DIABETES CARE, 1996, 19 (02) :142-145