The Reliability of Fluorescence Z-Scan Analysis in the Complex Environment of the Living Cell

被引:0
|
作者
Angerti, Isaac [1 ]
Karuka, Siddarth Reddy [1 ]
Kohler, John [1 ]
Chen, Yan [1 ]
Mueller, Joachim D. [1 ,2 ]
机构
[1] Univ Minnesota, Phys, Minneapolis, MN USA
[2] Inst Mol Virol, Minneapolis, MN USA
基金
美国国家卫生研究院;
关键词
D O I
暂无
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
888-Pos
引用
收藏
页码:183A / 183A
页数:1
相关论文
共 50 条
  • [21] Z-scan analysis for high order nonlinearities through Gaussian decomposition
    Tsigaridas, G
    Fakis, M
    Polyzos, I
    Persephonis, P
    Giannetas, V
    OPTICS COMMUNICATIONS, 2003, 225 (4-6) : 253 - 268
  • [22] Noise spectroscopy: Z-determination by statistical count-rate analysis (Z-scan)
    Langeveld, Willem G. J.
    Condron, Cathie
    Elsalim, Mashal
    Ingle, Mike
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 79 - 83
  • [23] Characterization of Cytoplasmic/Membrane-Bound Protein Mixtures by Z-Scan Fluorescence Fluctuation Spectroscopy
    Smith, Elizabeth M.
    Macdonald, Patrick J.
    Chen, Yan
    Albanesi, Joseph P.
    Mueller, Joachim D.
    BIOPHYSICAL JOURNAL, 2011, 100 (03) : 470 - 470
  • [24] Investigation of the excited-state absorption of a Ru dioxolene complex by the Z-scan technique
    Cassano, T
    Tommasi, R
    Meacham, AP
    Ward, MD
    JOURNAL OF CHEMICAL PHYSICS, 2005, 122 (15):
  • [25] Nonlinear optical absorption studies of an organo-metallic complex by Z-scan technique
    Sun, J.
    Guo, W. F.
    Wang, X. Q.
    Zhang, G. H.
    Sun, X. B.
    Zhu, L. Y.
    Ren, Q.
    Xu, D.
    OPTICS COMMUNICATIONS, 2007, 280 (01) : 183 - 187
  • [26] Sensitive Detection of Protein Binding to the Plasma Membrane with Dual-Color Z-Scan Fluorescence
    Angert, Isaac
    Karuka, Siddarth Reddy
    Hennen, Jared
    Chen, Yan
    Albanesi, Joseph P.
    Mansky, Louis M.
    Mueller, Joachim D.
    BIOPHYSICAL JOURNAL, 2020, 118 (02) : 281 - 293
  • [27] Simultaneous Characterization of Lateral Lipid and Prothrombin Diffusion Coefficients by Z-Scan Fluorescence Correlation Spectroscopy
    Stefl, Martin
    Kulakowska, Anna
    Hof, Martin
    BIOPHYSICAL JOURNAL, 2009, 97 (03) : LO1 - LO3
  • [28] Low axial drift stage and temperature controlled liquid cell for z-scan fluorescence correlation spectroscopy in an inverted confocal geometry
    Allgeyer, Edward S.
    Sterling, Sarah M.
    Neivandt, David J.
    Mason, Michael D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (05):
  • [29] The Z-scan Technique Using the Laguerre-Gaussian Beam: Variational Analysis
    Chen, R-P.
    Chen, J-L.
    Dai, C-Q.
    LASERS IN ENGINEERING, 2011, 21 (1-2) : 1 - 10
  • [30] Theoretical analysis of Z-scan using one dimensional partially coherent beams
    Liu, Yong-Xin
    Pu, Ji-Xiong
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2007, 19 (12): : 1947 - 1950